Instrumentation for Far‐Infrared Spectroscopy
View through CrossRef
Abstract
The various components of far‐infrared spectrometers are discussed in this article. For measurements above 100 cm
−1
, a standard silicon carbide (Globar) source may be used. For longer wavelengths, a high‐pressure mercury lamp is required. When higher radiance is required, synchrotrons emit much higher far‐infrared photon fluxes than either the Globar or the mercury lamp. Pneumatic (Golay) detectors were popular as far‐infrared detectors, as long as the modulation frequency was low. Despite their relatively low sensitivity, pyroelectric bolometers such as the deuterated triglycine sulfate (DTGS) detector are more commonly used because of their better high‐frequency response, which is necessary for Fourier transform infrared (FT‐IR) spectrometry. When very high sensitivity is required, liquid‐helium cooled bolometers are used. Most far‐infrared spectra are measured using an interferometer. In the early days of FT‐IR spectrometry, most interferometers were of the slow continuous‐scan or simple step‐scan variety; lamellar grating interferometers were used for very long‐wavelength measurements. Today, most far‐infrared FT‐IR spectrometers incorporate rapid‐scan interferometers of the same type used for mid‐infrared measurements. A number of special‐purpose instruments are also described, including the Genzel interferometer. All these instruments must be equipped with beamsplitters that are configured for far‐infrared operation. Poly(ethylene terephthalate), also known as Mylar or Melinex, is the most common material used to fabricate far‐infrared beamsplitters but other materials have better efficiency. These include solid silicon or silicon that has been vapor‐deposited onto Mylar.
Title: Instrumentation for Far‐Infrared Spectroscopy
Description:
Abstract
The various components of far‐infrared spectrometers are discussed in this article.
For measurements above 100 cm
−1
, a standard silicon carbide (Globar) source may be used.
For longer wavelengths, a high‐pressure mercury lamp is required.
When higher radiance is required, synchrotrons emit much higher far‐infrared photon fluxes than either the Globar or the mercury lamp.
Pneumatic (Golay) detectors were popular as far‐infrared detectors, as long as the modulation frequency was low.
Despite their relatively low sensitivity, pyroelectric bolometers such as the deuterated triglycine sulfate (DTGS) detector are more commonly used because of their better high‐frequency response, which is necessary for Fourier transform infrared (FT‐IR) spectrometry.
When very high sensitivity is required, liquid‐helium cooled bolometers are used.
Most far‐infrared spectra are measured using an interferometer.
In the early days of FT‐IR spectrometry, most interferometers were of the slow continuous‐scan or simple step‐scan variety; lamellar grating interferometers were used for very long‐wavelength measurements.
Today, most far‐infrared FT‐IR spectrometers incorporate rapid‐scan interferometers of the same type used for mid‐infrared measurements.
A number of special‐purpose instruments are also described, including the Genzel interferometer.
All these instruments must be equipped with beamsplitters that are configured for far‐infrared operation.
Poly(ethylene terephthalate), also known as Mylar or Melinex, is the most common material used to fabricate far‐infrared beamsplitters but other materials have better efficiency.
These include solid silicon or silicon that has been vapor‐deposited onto Mylar.
Related Results
Rancang Bangun Sistem Terapi Infrared Otomatis Untuk Terapi Far-Infrared Pada Spinal Cord
Rancang Bangun Sistem Terapi Infrared Otomatis Untuk Terapi Far-Infrared Pada Spinal Cord
Terapi infrared adalah terapi yang banyak dilakukan dengan memanfaatkan efek panas yang ditimbulkan pada tubuh manusia terutama pada permukaan kulit yang terpapar secara langsung. ...
Potency Of Manual Instrumentation To The Rotary Instrumentation For Primary Teeth Pulpectomies: A Clinical Comparrative Study
Potency Of Manual Instrumentation To The Rotary Instrumentation For Primary Teeth Pulpectomies: A Clinical Comparrative Study
Background: Using hand files in primary teeth is time-consuming, can lead to the formation of unwanted curvatures, and can cause iatrogenic errors. To overcome these difficulties, ...
Design of high transparent infrared stealth thin films based on FTO/Ag/FTO structure
Design of high transparent infrared stealth thin films based on FTO/Ag/FTO structure
Multi-spectral compatible stealth materials have become an imperative development trend, especially visible and infrared compatible stealth materials have become the most important...
Analysis of the instrumentation time and cleaning between manual and rotary techniques in deciduous molars
Analysis of the instrumentation time and cleaning between manual and rotary techniques in deciduous molars
The rotary instrumentation provides shorter instrumentation time with greater comfort for the patient but few studies have been conducted on primary teeth. Objective: this study co...
Comparison of the effectiveness of the protaper system versus hand instrumentation in endodontic retreatment: a scanning electron microscopy study
Comparison of the effectiveness of the protaper system versus hand instrumentation in endodontic retreatment: a scanning electron microscopy study
Several rotary systems have been evaluated for removal of endodontic filling materials from the canal. Moreover, studies focusing on the comparison of the effectiveness of rotary s...
Ultrafast laser sources and frequency conversion at high repetition rates
Ultrafast laser sources and frequency conversion at high repetition rates
Mode-locked laser sources have become a cornerstone technology for numerous applications and led to the development of groundbreaking optical tools and systems. In the optical freq...
Preparation of opal photonic crystal infrared stealth materials
Preparation of opal photonic crystal infrared stealth materials
With the development of infrared detection technology, the survival of military target is now under serious threat. Therefore, new infrared stealth technologies and materials are n...
Leveraging machine learning to enhance instrumentation accuracy in oil and gas extraction
Leveraging machine learning to enhance instrumentation accuracy in oil and gas extraction
The review explores the application of machine learning (ML) to improve the accuracy of instrumentation in the oil and gas industry. The paper discusses the challenges faced in ins...