Javascript must be enabled to continue!
Pre-diagnosis technology for short-circuit withstand capability of distribution transformer based on big data
View through CrossRef
Abstract
The short-circuit withstand capability test of distribution transformer has the characteristics of long test period, high cost, strong destructiveness, low qualification rate, and can not be verified by simulation or calculation. It has become the bottleneck restricting the engineering and industrialization development of transformer industry. Based on experimental big data, this paper uses the expert diagnosis method of fuzzy mathematics to establish a superior evaluation model. The typical design process of distribution transformers is scored by experts, and the short-circuit passing rate is calculated according to the real short-circuit test data. Linear regression analysis is used to establish the regression equation, and a pre-diagnosis technique for short-circuit withstand capability of distribution transformers is proposed. At the same time, the validity of the model is verified by the actual case, and the accurate pre-diagnosis of the resistance to short-circuit capability is realized. It breaks through the common key technologies of the transformer industry and provides an early warning for the quality control of power grid pro-ducts and the elimination of hidden danger products. It has important theoretical guiding significance and engineering application value.
Title: Pre-diagnosis technology for short-circuit withstand capability of distribution transformer based on big data
Description:
Abstract
The short-circuit withstand capability test of distribution transformer has the characteristics of long test period, high cost, strong destructiveness, low qualification rate, and can not be verified by simulation or calculation.
It has become the bottleneck restricting the engineering and industrialization development of transformer industry.
Based on experimental big data, this paper uses the expert diagnosis method of fuzzy mathematics to establish a superior evaluation model.
The typical design process of distribution transformers is scored by experts, and the short-circuit passing rate is calculated according to the real short-circuit test data.
Linear regression analysis is used to establish the regression equation, and a pre-diagnosis technique for short-circuit withstand capability of distribution transformers is proposed.
At the same time, the validity of the model is verified by the actual case, and the accurate pre-diagnosis of the resistance to short-circuit capability is realized.
It breaks through the common key technologies of the transformer industry and provides an early warning for the quality control of power grid pro-ducts and the elimination of hidden danger products.
It has important theoretical guiding significance and engineering application value.
Related Results
Simulation modeling study on short circuit ability of distribution transformer
Simulation modeling study on short circuit ability of distribution transformer
Abstract
Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical dama...
Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
Exploring Large Language Models Integration in the Histopathologic Diagnosis of Skin Diseases: A Comparative Study
Exploring Large Language Models Integration in the Histopathologic Diagnosis of Skin Diseases: A Comparative Study
Abstract
Introduction
The exact manner in which large language models (LLMs) will be integrated into pathology is not yet fully comprehended. This study examines the accuracy, bene...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
Research on mechanical fault diagnosis method of power transformer winding
Research on mechanical fault diagnosis method of power transformer winding
Today, the accuracy of the fault mechanical diagnosis of transformer winding is low and the fault types cannot be judged, this study proposes a machine condition diagnosis method o...
PLC Based Load Sharing of Transformers
PLC Based Load Sharing of Transformers
The transformer is very expensive and bulky power system equipment. It runs and feed the load for 24 hours a day. Sometimes the load on the transformer unexpectedly rises above its...
Two harmonic analysis of short circuit current in wind farm
Two harmonic analysis of short circuit current in wind farm
With the increase of capacity and the improvement of economy, doubly‐fed induction generator (DFIG) is gradually becoming the most widely used wind power generator in the world. DF...