SU‐GG‐T‐393: Optimization Platform Based on Monte Carlo Dose Calculation

View through CrossRef
Purpose: Dosimetry and planning for brachytherapy relies on the TG43 formula. This formalism, like any homogeneous dose calculation method, neglects the various effect of heterogeneities such as tissue composition, air, applicators and shielding. This study aims to incorporate Monte Carlo (MC) dose calculation within an inverse planning algorithm in order to improve the dose conformity, thus increasing the quality of the treatment. Material an Methods: Dose calculation and optimization is based on pre‐calculated Dose Distribution Kernel (DK). A DK represent the dose distribution produced by the irradiation of a single source located at one dwell position. The DKs are calculated using an automated CT based Monte Carlo software using the Geant4 toolkit. A research version of the inverse planning software IPSA was modified in order to read the set of DKs and use these dosimetric informations instead of the TG43 formula to generate the plan. This method was tested for two HDR brachytherapy sources: the microSelectron 192Ir source and the Axxent electronic source at 50 kVp. Results: The impact of the water approximation is found to depend on photon energy, with higher dose attenuation for the lower energies of the Axxent source in comparison with 192Ir with an underdosage of 5.4 % versus 2 % on the CTV V100. Incorporating Monte Carlo DK into the planning is found to correct the dose coverage for both energies. Conclusion: A new method to optimize high dose rate (HDR) brachytherapy plans that uses MC dosimetric information was developed. Including CT‐based information in MC dosimetry in the inverse planning process is shown to take into account the full range of scatter and heterogeneity conditions. This method can therefore predict and improve the dose coverage and homogeneity of clinical cases.
Title: SU‐GG‐T‐393: Optimization Platform Based on Monte Carlo Dose Calculation
Description:
Purpose: Dosimetry and planning for brachytherapy relies on the TG43 formula.
This formalism, like any homogeneous dose calculation method, neglects the various effect of heterogeneities such as tissue composition, air, applicators and shielding.
This study aims to incorporate Monte Carlo (MC) dose calculation within an inverse planning algorithm in order to improve the dose conformity, thus increasing the quality of the treatment.
Material an Methods: Dose calculation and optimization is based on pre‐calculated Dose Distribution Kernel (DK).
A DK represent the dose distribution produced by the irradiation of a single source located at one dwell position.
The DKs are calculated using an automated CT based Monte Carlo software using the Geant4 toolkit.
A research version of the inverse planning software IPSA was modified in order to read the set of DKs and use these dosimetric informations instead of the TG43 formula to generate the plan.
This method was tested for two HDR brachytherapy sources: the microSelectron 192Ir source and the Axxent electronic source at 50 kVp.
Results: The impact of the water approximation is found to depend on photon energy, with higher dose attenuation for the lower energies of the Axxent source in comparison with 192Ir with an underdosage of 5.
4 % versus 2 % on the CTV V100.
Incorporating Monte Carlo DK into the planning is found to correct the dose coverage for both energies.
Conclusion: A new method to optimize high dose rate (HDR) brachytherapy plans that uses MC dosimetric information was developed.
Including CT‐based information in MC dosimetry in the inverse planning process is shown to take into account the full range of scatter and heterogeneity conditions.
This method can therefore predict and improve the dose coverage and homogeneity of clinical cases.

Related Results

Monte Carlo methods: barrier option pricing with stable Greeks and multilevel Monte Carlo learning
Monte Carlo methods: barrier option pricing with stable Greeks and multilevel Monte Carlo learning
For discretely observed barrier options, there exists no closed solution under the Black-Scholes model. Thus, it is often helpful to use Monte Carlo simulations, which are easily a...
Research on Multi-Group Monte Carlo Calculations Based on Group Constants Generated by RMC
Research on Multi-Group Monte Carlo Calculations Based on Group Constants Generated by RMC
Abstract Nowadays, deterministic two-step or Monte Carlo methods are commonly used in core physics calculations. However, with the development of reactor core design, tradi...
SU‐FF‐T‐358: PlanCheck: A System for Routine Clinical Comparison of IMRT Treatment Plans with Monte Carlo Recalculations
SU‐FF‐T‐358: PlanCheck: A System for Routine Clinical Comparison of IMRT Treatment Plans with Monte Carlo Recalculations
Purpose: Current IMRT QA methods are cumbersome and are not comprehensive. The purpose of the PlanCheck dose recalculation system is to provide independent verification that MLC le...
Automation of the Monte Carlo simulation of medical linear accelerators
Automation of the Monte Carlo simulation of medical linear accelerators
The main result of this thesis is a software system, called PRIMO, which simulates clinical linear accelerators and the subsequent dose distributions using the Monte Carlo method. ...
Evaluating View Factors Using a Hybrid Monte-Carlo Method
Evaluating View Factors Using a Hybrid Monte-Carlo Method
AbstractThis paper demonstrates that the well-known method for calculating view factors, the Monte Carlo method, combined with ray tracing is not necessarily the most efficient str...
SU‐FF‐T‐440: Validation of Accuray Multi Plan Monte Carlo Treatment Plans
SU‐FF‐T‐440: Validation of Accuray Multi Plan Monte Carlo Treatment Plans
Purpose: To validate Accuray Monte Carlo treatment plans in various heterogeneous phantom systems. Materials and Methods: Monte Carlo Dose Calculation algorithm is considered to be...
REGULAR ARTICLES
REGULAR ARTICLES
L. Cowen and C. J. Schwarz       657Les Radio‐tags, en raison de leur détectabilitéélevée, ...

Back to Top