Outcome of treatment of intra-articular distal end radius fractures by volar locking plate versus bridging external fixator augmented by single K-wire through radial styloid

View through CrossRef
Background: Distal radius fractures are common injuries occurring more frequently than any other fracture, and remain one of the most frequent skeletal injuries treated by orthopaedic or trauma surgeons. They are considered the most common fracture of the upper extremity. The use of percutaneous pin fixation, external fixation devices that permit distraction and palmar translation, low-profile internal fixation plates and implants, arthroscopically assisted reduction, and grafting techniques including bone-graft substitutes all have contributed to improving fracture stability and outcome. Methods: This is a prospective study consisting of 30 patients, who were treated with volar locking plate or K-wire augmented external fixation for intra-articular commented distal radius fractures (AO type C) at Rajendra institute of medical sciences between November 2020 and January 2023. The 15 patients were treated with open reduction using the volar approach and locking plate were used while 15 patients were treated with closed reduction under fluoroscopy, distraction with the external fixator (Joshi type external fixator) along with K-wire fixation for additional stability used. Result: The ORIF with plating group showed better functional outcomes in Green and O'Brien compared to ex fix group. The radiographic results in the ORIF group were more favorable than in the EF group. Conclusions: We found that both ORIF with plating and external fixation represent treatment choices for distal radius fractures. ORIF had better functional and radiological outcomes according to Green and O'Brien and Sarmiento scoring systems when compared to external fixation. ORIF had less incidence of complications compared with external fixation.
Title: Outcome of treatment of intra-articular distal end radius fractures by volar locking plate versus bridging external fixator augmented by single K-wire through radial styloid
Description:
Background: Distal radius fractures are common injuries occurring more frequently than any other fracture, and remain one of the most frequent skeletal injuries treated by orthopaedic or trauma surgeons.
They are considered the most common fracture of the upper extremity.
The use of percutaneous pin fixation, external fixation devices that permit distraction and palmar translation, low-profile internal fixation plates and implants, arthroscopically assisted reduction, and grafting techniques including bone-graft substitutes all have contributed to improving fracture stability and outcome.
Methods: This is a prospective study consisting of 30 patients, who were treated with volar locking plate or K-wire augmented external fixation for intra-articular commented distal radius fractures (AO type C) at Rajendra institute of medical sciences between November 2020 and January 2023.
The 15 patients were treated with open reduction using the volar approach and locking plate were used while 15 patients were treated with closed reduction under fluoroscopy, distraction with the external fixator (Joshi type external fixator) along with K-wire fixation for additional stability used.
Result: The ORIF with plating group showed better functional outcomes in Green and O'Brien compared to ex fix group.
The radiographic results in the ORIF group were more favorable than in the EF group.
Conclusions: We found that both ORIF with plating and external fixation represent treatment choices for distal radius fractures.
ORIF had better functional and radiological outcomes according to Green and O'Brien and Sarmiento scoring systems when compared to external fixation.
ORIF had less incidence of complications compared with external fixation.

Related Results

Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Introduction: The aim of this study is to illustrate a case in which the use of a dorsal spanning plate followed by volar plating may be indicated in the setting of a complex intra...
SURGICAL OUTCOMES OF VOLAR LOCKING PLATE VERSUS K-WIRES FIXATION FOR DISTAL RADIUS FRACTURES
SURGICAL OUTCOMES OF VOLAR LOCKING PLATE VERSUS K-WIRES FIXATION FOR DISTAL RADIUS FRACTURES
Background and Objective: The most common hand fractures among adult population are distal radius fractures and optimal management of these fractures remains controversial. Several...
A novel technique for full anatomic restoration of volar tilt in distal radius fracture
A novel technique for full anatomic restoration of volar tilt in distal radius fracture
Abstract Objective: The aim of this study was to present a technique that allows the surgeon to easily and reliably achieve volar tilt in dorsally displaced distal radius fract...
FUNCTIONAL OUTCOME OF VOLAR LOCKING PLATE FIXATION IN ADULTS FOR DISPLACED INTRA ARTICULAR FRACTURE OF DISTAL RADIUS
FUNCTIONAL OUTCOME OF VOLAR LOCKING PLATE FIXATION IN ADULTS FOR DISPLACED INTRA ARTICULAR FRACTURE OF DISTAL RADIUS
Background: Distal radius fractures are among the most frequently encountered orthopedic injuries, particularly affecting children, adolescents, and elderly individuals due to fall...
Outcome of volar Barton fractures of distal radius managed with open reduction and internal fixation with volar locking plate
Outcome of volar Barton fractures of distal radius managed with open reduction and internal fixation with volar locking plate
Background: Volar Barton fractures of distal radius almost always require a surgical fixation. Near anatomical reduction and a stout fixation is imperative for good outcome. The pr...
OUTCOME OF THE DISTAL RADIUS FRACTURES MANAGED WITH ACROSS WRIST EXTERNAL FIXATOR VS BUTTRESS PLATE
OUTCOME OF THE DISTAL RADIUS FRACTURES MANAGED WITH ACROSS WRIST EXTERNAL FIXATOR VS BUTTRESS PLATE
Background: Distal radius fracture is one of the most common injuries presented to emergency department and can be presented in any age group. In young patients the most common cau...