Javascript must be enabled to continue!
Clinical Outcomes of Intra-Articular Distal Radius Fractures Treated with Volar Locking Plate Fixation
View through CrossRef
Distal radius fractures are extremely common, accounting for one-sixth of all fractures seen in the emergency department. Intra-articular fractures present a greater challenge due to joint involvement. These fractures occur more commonly in women than in men, increase in frequency with advancing age, and result from low-energy falls more often than from high-energy trauma. The work aims to evaluate the predictors of clinical and radiological outcomes of intra-articular distal radius fractures treated by open reduction and internal fixation using a volar locking plate. A total of 20 patients were included in this study, conducted between August 2024 and August 2025 at the Orthopedic Department, Omar Al-Mukhtar University. Patients aged between 40 and 65 years with intra-articular distal radius fractures were managed surgically using a volar locking plate. The majority of patients demonstrated good to excellent functional outcomes, with significant improvement in Mayo scores over a one–year follow-up period. Range of motion and grip strength improved with early return to activities of daily living. The majority of injuries were caused by falls, while a smaller proportion resulted from road traffic accidents. Among the 20 patients included in the study, the left distal radius was more commonly affected (55%) compared to the right side (45%). The study population consisted of 13 females (65%) and 7 males (35%), with a mean age of 50.35 years. The average time to fracture healing was 2.4 months, with most fractures healing within two months. Patients were followed up for a period of 6-12 months. Fixation of the distal radius fractures with a volar locked plate is very important for a good functional outcome and restoring the anatomical function of the joint. Radiographic alignment (including articular congruity) is a key determinant of outcome. Early motion and stable fixation help regain function and minimize stiffness.
Title: Clinical Outcomes of Intra-Articular Distal Radius Fractures Treated with Volar Locking Plate Fixation
Description:
Distal radius fractures are extremely common, accounting for one-sixth of all fractures seen in the emergency department.
Intra-articular fractures present a greater challenge due to joint involvement.
These fractures occur more commonly in women than in men, increase in frequency with advancing age, and result from low-energy falls more often than from high-energy trauma.
The work aims to evaluate the predictors of clinical and radiological outcomes of intra-articular distal radius fractures treated by open reduction and internal fixation using a volar locking plate.
A total of 20 patients were included in this study, conducted between August 2024 and August 2025 at the Orthopedic Department, Omar Al-Mukhtar University.
Patients aged between 40 and 65 years with intra-articular distal radius fractures were managed surgically using a volar locking plate.
The majority of patients demonstrated good to excellent functional outcomes, with significant improvement in Mayo scores over a one–year follow-up period.
Range of motion and grip strength improved with early return to activities of daily living.
The majority of injuries were caused by falls, while a smaller proportion resulted from road traffic accidents.
Among the 20 patients included in the study, the left distal radius was more commonly affected (55%) compared to the right side (45%).
The study population consisted of 13 females (65%) and 7 males (35%), with a mean age of 50.
35 years.
The average time to fracture healing was 2.
4 months, with most fractures healing within two months.
Patients were followed up for a period of 6-12 months.
Fixation of the distal radius fractures with a volar locked plate is very important for a good functional outcome and restoring the anatomical function of the joint.
Radiographic alignment (including articular congruity) is a key determinant of outcome.
Early motion and stable fixation help regain function and minimize stiffness.
Related Results
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Fixation of 3-Part Intra Articular Distal Radius Fracture with Combined Volar Plate and Dorsal Spanning Plate: A Case Report
Introduction: The aim of this study is to illustrate a case in which the use of a dorsal spanning plate followed by volar plating may be indicated in the setting of a complex intra...
Flexor Pollicis Longus Tendon Rupture after Distal Radius Volar Plating and Reconstruction with Interpositional Palmaris Tendon Graft: A Case Report
Flexor Pollicis Longus Tendon Rupture after Distal Radius Volar Plating and Reconstruction with Interpositional Palmaris Tendon Graft: A Case Report
Introduction: Distal radius fractures constitute one of the most prevalent upper extremity orthopedic injuries, predominantly resulting from falls onto an outstretched hand with an...
FUNCTIONAL OUTCOME OF VOLAR LOCKING PLATE FIXATION IN ADULTS FOR DISPLACED INTRA ARTICULAR FRACTURE OF DISTAL RADIUS
FUNCTIONAL OUTCOME OF VOLAR LOCKING PLATE FIXATION IN ADULTS FOR DISPLACED INTRA ARTICULAR FRACTURE OF DISTAL RADIUS
Background: Distal radius fractures are among the most frequently encountered orthopedic injuries, particularly affecting children, adolescents, and elderly individuals due to fall...
SURGICAL OUTCOMES OF VOLAR LOCKING PLATE VERSUS K-WIRES FIXATION FOR DISTAL RADIUS FRACTURES
SURGICAL OUTCOMES OF VOLAR LOCKING PLATE VERSUS K-WIRES FIXATION FOR DISTAL RADIUS FRACTURES
Background and Objective: The most common hand fractures among adult population are distal radius fractures and optimal management of these fractures remains controversial. Several...
A novel technique for full anatomic restoration of volar tilt in distal radius fracture
A novel technique for full anatomic restoration of volar tilt in distal radius fracture
Abstract
Objective: The aim of this study was to present a technique that allows the surgeon to easily and reliably achieve volar tilt in dorsally displaced distal radius fract...
Outcome of volar Barton fractures of distal radius managed with open reduction and internal fixation with volar locking plate
Outcome of volar Barton fractures of distal radius managed with open reduction and internal fixation with volar locking plate
Background: Volar Barton fractures of distal radius almost always require a surgical fixation. Near anatomical reduction and a stout fixation is imperative for good outcome. The pr...
Hospital Stay Duration and Postoperative Complications among Patients Undergoing Volar Buttress Plate for Fixation in Volar Barton’s Fracture of the Distal Radius
Hospital Stay Duration and Postoperative Complications among Patients Undergoing Volar Buttress Plate for Fixation in Volar Barton’s Fracture of the Distal Radius
Introduction: Volar Barton’s fractures of the distal radius are complex injuries requiring precise surgical intervention to ensure optimal functional outcomes and minimize complica...
Hospital Stay Duration and Postoperative Complications among Patients Undergoing Volar Buttress Plate for Fixation in Volar Barton’s Fracture of the Distal Radius
Hospital Stay Duration and Postoperative Complications among Patients Undergoing Volar Buttress Plate for Fixation in Volar Barton’s Fracture of the Distal Radius
Introduction: Volar Barton’s fractures of the distal radius are complex injuries requiring precise surgical intervention to ensure optimal functional outcomes and minimize complica...

