Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Research on Fault Location in Distribution Network Based on Fast Fault Transfer Arc Extinguishing Device

View through CrossRef
Abstract In the distribution network equipped with fast fault transfer arc extinguishing device, after a single-phase grounding fault occurs, the fault phase bus is quickly grounded to realize arc extinguishing. At the same time, the traveling wave signal generated during the grounding process of the fault phase bus can realize fault location. The traveling wave signal is subjected to phase-mode transformation, and the time difference of the zero-mode component mutation detected twice at the exit of the fault line is to be recorded. This time difference is the time which it takes for the zero-mode component to go to and fro once between the bus and the fault point. And then the fault distance can be calculated based on it. The integration of arc extinguishing and fault location is realized. The AT P simulation software is used to realize the fault simulation of distribution network. And the accuracy and feasibility of the proposed fault location method are verified.
Title: Research on Fault Location in Distribution Network Based on Fast Fault Transfer Arc Extinguishing Device
Description:
Abstract In the distribution network equipped with fast fault transfer arc extinguishing device, after a single-phase grounding fault occurs, the fault phase bus is quickly grounded to realize arc extinguishing.
At the same time, the traveling wave signal generated during the grounding process of the fault phase bus can realize fault location.
The traveling wave signal is subjected to phase-mode transformation, and the time difference of the zero-mode component mutation detected twice at the exit of the fault line is to be recorded.
This time difference is the time which it takes for the zero-mode component to go to and fro once between the bus and the fault point.
And then the fault distance can be calculated based on it.
The integration of arc extinguishing and fault location is realized.
The AT P simulation software is used to realize the fault simulation of distribution network.
And the accuracy and feasibility of the proposed fault location method are verified.

Related Results

Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems. Concerning fault detection, interv...
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Abstract:Little attention had been paid to the intracontinental strike‐slip faults of the Tibetan Plateau. Since the discovery of the Longriba fault using re‐measured GPS data in 2...
Fault location of distribution network with distributed generation based on Karrenbauer transform and support vector machine regression
Fault location of distribution network with distributed generation based on Karrenbauer transform and support vector machine regression
As the capacity and scale of distribution networks continue to expand, and distributed generation technology is increasingly mature, the traditional fault location is no longer app...
Data-driven Fault Diagnosis for Cyber-Physical Systems
Data-driven Fault Diagnosis for Cyber-Physical Systems
The concept of Industry 4.0 uses cyber-physical systems and the Internet of Things to create "smart factories" that enable automated and connected production. However, the complex ...
Collision orogeny at arc‐arc junctions in the Japanese Islands
Collision orogeny at arc‐arc junctions in the Japanese Islands
Abstract In the Japanese Islands, collision tectonics are operating at arc‐arc junctions in three regions: Hokkaido, Central Japan and Kyushu. Hokkaido is situated at the jun...

Back to Top