Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Fault location of distribution network with distributed generation based on Karrenbauer transform and support vector machine regression

View through CrossRef
As the capacity and scale of distribution networks continue to expand, and distributed generation technology is increasingly mature, the traditional fault location is no longer applicable to an active distribution network and "two-way" power flow structure. In this paper, a fault location method based on Karrenbauer transform and support vector machine regression (SVR) is proposed. Firstly, according to the influence of Karrenbauer transformation on phase angle difference before and after section fault in a low-voltage active distribution network, the fault regions and types are inferred preliminarily. Then, in the feature extraction stage, combined with the characteristics of distribution network fault mechanism, the fault feature sample set is established by using the phase angle difference of the Karrenbauer current. Finally, the fault category prediction model based on SVR was established to solve the problem of a single-phase mode transformation modulus and the indistinct identification of two-phase short circuits, then more accurate fault segments and categories were obtained. The proposed fault location method is simulated and verified by building a distribution network system model. The results show that compared with other methods in the field of fault detection, the fault location accuracy of the proposed method can reach 98.56%, which can enhance the robustness of rapid fault location.
Title: Fault location of distribution network with distributed generation based on Karrenbauer transform and support vector machine regression
Description:
As the capacity and scale of distribution networks continue to expand, and distributed generation technology is increasingly mature, the traditional fault location is no longer applicable to an active distribution network and "two-way" power flow structure.
In this paper, a fault location method based on Karrenbauer transform and support vector machine regression (SVR) is proposed.
Firstly, according to the influence of Karrenbauer transformation on phase angle difference before and after section fault in a low-voltage active distribution network, the fault regions and types are inferred preliminarily.
Then, in the feature extraction stage, combined with the characteristics of distribution network fault mechanism, the fault feature sample set is established by using the phase angle difference of the Karrenbauer current.
Finally, the fault category prediction model based on SVR was established to solve the problem of a single-phase mode transformation modulus and the indistinct identification of two-phase short circuits, then more accurate fault segments and categories were obtained.
The proposed fault location method is simulated and verified by building a distribution network system model.
The results show that compared with other methods in the field of fault detection, the fault location accuracy of the proposed method can reach 98.
56%, which can enhance the robustness of rapid fault location.

Related Results

Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems. Concerning fault detection, interv...
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Abstract:Little attention had been paid to the intracontinental strike‐slip faults of the Tibetan Plateau. Since the discovery of the Longriba fault using re‐measured GPS data in 2...
Late Quaternary Activity: Kouma Fault
Late Quaternary Activity: Kouma Fault
The Kouma Fault, located at the northern foot of the Mangshan Mountain in Luoyang City, Henan Province, China, is an active fault newly discovered in the field seismic geological s...
Maximum allowable distributed generation with consideration of fault ride through requirement and utility protection system
Maximum allowable distributed generation with consideration of fault ride through requirement and utility protection system
Distribution systems are changing from one-source supplying structure into multi-source supplying structure with participations of distributed generations. The strong increase in n...
Data-driven Fault Diagnosis for Cyber-Physical Systems
Data-driven Fault Diagnosis for Cyber-Physical Systems
The concept of Industry 4.0 uses cyber-physical systems and the Internet of Things to create "smart factories" that enable automated and connected production. However, the complex ...
Analysis of the Influence of Fault Fracture Zone on Mining Response Based on FDM-DEM Coupling
Analysis of the Influence of Fault Fracture Zone on Mining Response Based on FDM-DEM Coupling
Fault slip will cause a change in mining stress at the longwall face, which will cause adverse effects. In this study, on the basis of Fast Lagrangian Analysis of Continua in 3 Dim...
Low-temperature thermochronology of fault zones
Low-temperature thermochronology of fault zones
<p>Thermal signatures as well as timing of fault motions can be constrained by thermochronological analyses of fault-zone rocks (e.g., Tagami, 2012, 2019).&#1...

Back to Top