Javascript must be enabled to continue!
Comparison of the Bone-Anchored Pendulum Appliance and the Bone-Anchored Intraoral Bodily Molar Distalizer: An Original Research
View through CrossRef
ABSTRACT
Introduction:
With the advent of mini-implants, Class II correction has become routine. The study’s goal was to compare the “Bone-Anchored Pendulum Appliance (BAPA)” to the “Bone-Anchored Intraoral Bodily Molar Distalizer (BAIBMD)” in terms of clinical efficacy.
Materials and Procedures:
Five boys and five girls were among the 10 patients in this split-mouth trial who had to have their molars distalized. On one side, BAPA Construction, and on the other, BAIBMD was piloted. A titanium mini-screw was used to secure both appliances to the bone since this was a spilled-mouth technique. The first molar bands to apply 200 g of force were used for both devices, as with all the other components that were similar for both appliances. For both sides, the nature, duration, and rate of tooth movement were compared. Using the Wilcoxon signed-rank test, descriptive statistics for several parameters were examined.
Results:
Distalization was accomplished on both sides with clinical success. The rate of distalization did not show any significant variation. Less time was needed for distalization with BAPA, as evidenced by the statistically substantial variances in treatment duration between the two groups. Molar tipping was noticed in BAPA, and it was statistically significant.
Conclusion:
While the pace of distalization was equal for both appliances, BAIBMD required more time than BAPA but resulted in a distal tooth movement that was mostly translatory in nature.
Title: Comparison of the Bone-Anchored Pendulum Appliance and the Bone-Anchored Intraoral Bodily Molar Distalizer: An Original Research
Description:
ABSTRACT
Introduction:
With the advent of mini-implants, Class II correction has become routine.
The study’s goal was to compare the “Bone-Anchored Pendulum Appliance (BAPA)” to the “Bone-Anchored Intraoral Bodily Molar Distalizer (BAIBMD)” in terms of clinical efficacy.
Materials and Procedures:
Five boys and five girls were among the 10 patients in this split-mouth trial who had to have their molars distalized.
On one side, BAPA Construction, and on the other, BAIBMD was piloted.
A titanium mini-screw was used to secure both appliances to the bone since this was a spilled-mouth technique.
The first molar bands to apply 200 g of force were used for both devices, as with all the other components that were similar for both appliances.
For both sides, the nature, duration, and rate of tooth movement were compared.
Using the Wilcoxon signed-rank test, descriptive statistics for several parameters were examined.
Results:
Distalization was accomplished on both sides with clinical success.
The rate of distalization did not show any significant variation.
Less time was needed for distalization with BAPA, as evidenced by the statistically substantial variances in treatment duration between the two groups.
Molar tipping was noticed in BAPA, and it was statistically significant.
Conclusion:
While the pace of distalization was equal for both appliances, BAIBMD required more time than BAPA but resulted in a distal tooth movement that was mostly translatory in nature.
Related Results
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Optimal control for hover pendulum motion of unmanned helicopter
Optimal control for hover pendulum motion of unmanned helicopter
Purpose
During the authors’ practical experiments about designing hover controller for unmanned helicopter, they find pendulum motion exists, thus destroying their expected control...
OPTIMALISASI PERAWATAN ALAT-ALAT KESELAMATAN SEBAGAI PENUNJANG KESELAMATAN AWAK KAPAL DI KN. BIMA SAKTI
OPTIMALISASI PERAWATAN ALAT-ALAT KESELAMATAN SEBAGAI PENUNJANG KESELAMATAN AWAK KAPAL DI KN. BIMA SAKTI
As for target of writing of this handing out is to know optimalization treatment of safety appliance as supporter safety of crew man in KN. Bima Sakti. Pursuant to the target, hen...
The efficiency of a customized distalizer with Variety SP® screws anchored on palatal miniscrews for upper molar distalization
The efficiency of a customized distalizer with Variety SP® screws anchored on palatal miniscrews for upper molar distalization
ABSTRACT Objective: To assess the effectiveness of a customized distalizer with Variety SP® screws anchored on palatal miniscrews for upper molar distalization. Methods: Seventee...
Evaluation of Two Bone Anchored Appliances During En Masse Distalization of Maxillary Buccal Segment with Class II Patients; A Comparative Clinical Study
Evaluation of Two Bone Anchored Appliances During En Masse Distalization of Maxillary Buccal Segment with Class II Patients; A Comparative Clinical Study
Objective: to assess quality of orthodontic tooth movement during distalization by two different skeletally anchored distalizing appliances. Patients and methods: the current study...
Accurate Clock Pendulums
Accurate Clock Pendulums
Abstract
The Shortt clock, made in the 1920s, is the most famous accurate clock pendulum ever known, having an accuracy of one second per year when kept at nearly co...
MATHEMATICAL PENDULUM MODEL WITH MOBILE SUSPENSION POINT
MATHEMATICAL PENDULUM MODEL WITH MOBILE SUSPENSION POINT
Background. The new dynamic problem, which is posed and solved in this article, is a theoretical generalization of the well-known classical problem of free oscillations of a mathem...
Control of an Elasto-Plastic Pendulum
Control of an Elasto-Plastic Pendulum
Abstract
An elasto-plastic pendulum performing large rigid-body rotations and vibrating in the small-strain regime is studied. Spatial distribution of plastic zones ...