A-117 Performance Evaluation of five Sentinel Diagnostics’ Assays on Beckman Coulter DxC 500 AU Clinical Chemistry Analyzer
View through CrossRef
Abstract
Objective
The aim of this study is to evaluate the analytical performances of the following Sentinel Diagnostics’ assays: ACE Liquid, Lp(a) Ultra, Pancreatic Amylase, Lipase NG, Albumin BCP on the Beckman Coulter DxC 500 AU Clinical Chemistry Analyzer.
Methods
Performance evaluation included Limit of Blank (LoB), Limit of Detection (LoD), Limit of Quantitation (LoQ), linearity, intra assay precision, inter assay precision, calibration stability, on board reagent stability and instrument correlation, following the current CLSI guidelines protocols. Analytical Measuring Range (AMR) was defined through linearity and sensitivity.
Results
Summary of the analytical performances for all the assays tested is reported in table below.
Conclusions
All assays showed good results for the parameters tested on the Beckman Coulter DxC 500 AU Clinical Chemistry Analyzer making these kits very suitable for a routine measurement of these analytes.
Oxford University Press (OUP)
Title: A-117 Performance Evaluation of five Sentinel Diagnostics’ Assays on Beckman Coulter DxC 500 AU Clinical Chemistry Analyzer
Description:
Abstract
Objective
The aim of this study is to evaluate the analytical performances of the following Sentinel Diagnostics’ assays: ACE Liquid, Lp(a) Ultra, Pancreatic Amylase, Lipase NG, Albumin BCP on the Beckman Coulter DxC 500 AU Clinical Chemistry Analyzer.
Methods
Performance evaluation included Limit of Blank (LoB), Limit of Detection (LoD), Limit of Quantitation (LoQ), linearity, intra assay precision, inter assay precision, calibration stability, on board reagent stability and instrument correlation, following the current CLSI guidelines protocols.
Analytical Measuring Range (AMR) was defined through linearity and sensitivity.
Results
Summary of the analytical performances for all the assays tested is reported in table below.
Conclusions
All assays showed good results for the parameters tested on the Beckman Coulter DxC 500 AU Clinical Chemistry Analyzer making these kits very suitable for a routine measurement of these analytes.
Related Results
520. Development of Cefepime-taniborbactam MIC Antimicrobial Susceptibility Test (AST) for Enterobacterales and Pseudomonas aeruginosa on MicroScan Dried Gram-negative MIC Panels
520. Development of Cefepime-taniborbactam MIC Antimicrobial Susceptibility Test (AST) for Enterobacterales and Pseudomonas aeruginosa on MicroScan Dried Gram-negative MIC Panels
Abstract
Background
Automated AST devices are critical to inform appropriate care of patients with bacterial infections. Cefepim...
Coulter Method for the detection of Physiological parameters v1
Coulter Method for the detection of Physiological parameters v1
Instrument A Coulter counter [1] [2] is an apparatus for counting and sizing particles suspended in electrolytes. It is used for cells, bacteria, prokaryotic cells and virus parti...
Multi-Resolution Ocean Color roducts to support the Copernicus Marine High-Resolution Coastal Service 
Multi-Resolution Ocean Color roducts to support the Copernicus Marine High-Resolution Coastal Service 
High-quality satellite-based ocean colour products can provide valuable support and insights in the management and monitoring of coastal ecosystems. Today’s availability ...
Two Suspected Cases of Immunoglobulin-Mediated Interference Causing Falsely Low Vancomycin Concentrations with the Beckman PETINIA Method
Two Suspected Cases of Immunoglobulin-Mediated Interference Causing Falsely Low Vancomycin Concentrations with the Beckman PETINIA Method
OBJECTIVE
To describe 2 recent cases of suspected immunoglobulin-mediated interference with the Beckman Coulter particle–enhanced turbidimetric inhibition immun...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Systemic Sentinel Lymph Node Detection Using Fluorescence Imaging After Indocyanine Green Intravenous Injection in Colorectal Cancer: Protocol for a Feasibility Study (Preprint)
Systemic Sentinel Lymph Node Detection Using Fluorescence Imaging After Indocyanine Green Intravenous Injection in Colorectal Cancer: Protocol for a Feasibility Study (Preprint)
BACKGROUND
Nodal staging is a major concern in colorectal cancer as it is an important prognostic factor. Several techniques that could potentially improve ...
A-118 Sigma Metric Performance of Chemistry Assays on 4 Instrument Systems
A-118 Sigma Metric Performance of Chemistry Assays on 4 Instrument Systems
Abstract
Background
Chemistry panels play a crucial role in determining a person’s general health and well-being. These tests ev...
7
th
International Symposium on Enabling Technologies for Life Sciences (ETP)
7
th
International Symposium on Enabling Technologies for Life Sciences (ETP)
The seventh in the series of ETP Symposia (see
Rapid Communications in Mass Spectrometry
2012,
26
, ...