Javascript must be enabled to continue!
Coulter Method for the detection of Physiological parameters v1
View through CrossRef
Instrument A Coulter counter [1] [2] is an apparatus for counting and sizing particles suspended in electrolytes. It is used for cells, bacteria, prokaryotic cells and virus particles.[3] A typical Coulter counter has one or more microchannels that separate two chambers containing electrolyte solutions. As fluid containing particles or cells is drawn through each microchannel, each particle causes a brief change to the electrical resistance of the liquid. The counter detects these changes in electrical resistance. Coulter principle The Coulter principle states that particles pulled through an orifice, concurrent with an electric current, produce a change in impedance that is proportional to the volume of the particle traversing the orifice. This pulse in impedance originates from the displacement of electrolyte caused by the particle. The Coulter principle was named for its inventor, Wallace H. Coulter. The principle has found commercial success in the medical industry, particularly in hematology, where it can be applied to count and size the various cells that make up whole blood. Cells, being poorly conductive particles, alter the effective cross-section of the conductive microchannel. If these particles are less conductive than the surrounding liquid medium, the electrical resistance across the channel increases, causing the electric current passing across the channel to briefly decrease. By monitoring such pulses in electric current, the number of particles for a given volume of fluid can be counted. The size of the electric current change is related to the size of the particle, enabling a particle size distribution to be measured, which can be correlated to mobility, surface charge, and concentration of the particles. The Coulter Counter is a vital constituent of today's hospital laboratory. Its primary function being the quick and accurate analysis of complete blood counts (often referred to as CBC). The CBC is used to determine the number or proportion of white and red blood cells in the body. Previously, this procedure involved preparing a blood cell stain and manually counting each type of cell under a microscope, a process that typically took a half-hour. Coulter Counters have a wide variety of applications including paint, ceramics, glass, molten metals and food manufacture. They are also routinely employed for quality control. A Coulter counter played an important role in the development of the first ever cell sorter, and was involved in the early days of the development of flow cytometry. Even today, some flow cytometers utilize the Coulter Principle to provide highly accurate information about cell size and count. Many investigators have designed a variety of devices based on the Coulter Principle, and generated peer-reviewed publications featuring data generated by these devices. A few of these devices have also been commercialized. All implementations of the Coulter Principle feature trade offs between sensitivity, noise shielding, solvent compatibility, speed of measurement, sample volume, dynamic range, and reliability of device manufacture.
Springer Science and Business Media LLC
Title: Coulter Method for the detection of Physiological parameters v1
Description:
Instrument A Coulter counter [1] [2] is an apparatus for counting and sizing particles suspended in electrolytes.
It is used for cells, bacteria, prokaryotic cells and virus particles.
[3] A typical Coulter counter has one or more microchannels that separate two chambers containing electrolyte solutions.
As fluid containing particles or cells is drawn through each microchannel, each particle causes a brief change to the electrical resistance of the liquid.
The counter detects these changes in electrical resistance.
Coulter principle The Coulter principle states that particles pulled through an orifice, concurrent with an electric current, produce a change in impedance that is proportional to the volume of the particle traversing the orifice.
This pulse in impedance originates from the displacement of electrolyte caused by the particle.
The Coulter principle was named for its inventor, Wallace H.
Coulter.
The principle has found commercial success in the medical industry, particularly in hematology, where it can be applied to count and size the various cells that make up whole blood.
Cells, being poorly conductive particles, alter the effective cross-section of the conductive microchannel.
If these particles are less conductive than the surrounding liquid medium, the electrical resistance across the channel increases, causing the electric current passing across the channel to briefly decrease.
By monitoring such pulses in electric current, the number of particles for a given volume of fluid can be counted.
The size of the electric current change is related to the size of the particle, enabling a particle size distribution to be measured, which can be correlated to mobility, surface charge, and concentration of the particles.
The Coulter Counter is a vital constituent of today's hospital laboratory.
Its primary function being the quick and accurate analysis of complete blood counts (often referred to as CBC).
The CBC is used to determine the number or proportion of white and red blood cells in the body.
Previously, this procedure involved preparing a blood cell stain and manually counting each type of cell under a microscope, a process that typically took a half-hour.
Coulter Counters have a wide variety of applications including paint, ceramics, glass, molten metals and food manufacture.
They are also routinely employed for quality control.
A Coulter counter played an important role in the development of the first ever cell sorter, and was involved in the early days of the development of flow cytometry.
Even today, some flow cytometers utilize the Coulter Principle to provide highly accurate information about cell size and count.
Many investigators have designed a variety of devices based on the Coulter Principle, and generated peer-reviewed publications featuring data generated by these devices.
A few of these devices have also been commercialized.
All implementations of the Coulter Principle feature trade offs between sensitivity, noise shielding, solvent compatibility, speed of measurement, sample volume, dynamic range, and reliability of device manufacture.
Related Results
Determination of Reticulocytes: Three Methods Compared
Determination of Reticulocytes: Three Methods Compared
Abstract
Determination of reticulocytes in peripheral blood is a valuable tool for getting information about erythropoiesis of an individual. For many years, reticul...
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Impact of Common Anticoagulants on Complete Blood Count Parameters Among Humans
Abstract
Introduction
Among the most frequently used anticoagulants in hematological testing are tetra-acetic acid (EDTA), sodium citrate, and sodium heparin. However, there is a n...
HemoCue against Coulter LH-750 in the estimation of hemoglobin levels of blood donors in mobile collection settings: a comparative study
HemoCue against Coulter LH-750 in the estimation of hemoglobin levels of blood donors in mobile collection settings: a comparative study
Background: The fast and outpatient setting for a determination of the hemoglobin (Hb) level is a well-recognized prerequisite to detect anemia in blood donors. This study aimed to...
Two Suspected Cases of Immunoglobulin-Mediated Interference Causing Falsely Low Vancomycin Concentrations with the Beckman PETINIA Method
Two Suspected Cases of Immunoglobulin-Mediated Interference Causing Falsely Low Vancomycin Concentrations with the Beckman PETINIA Method
OBJECTIVE
To describe 2 recent cases of suspected immunoglobulin-mediated interference with the Beckman Coulter particle–enhanced turbidimetric inhibition immun...
Abnormal Status Detection of Catenary Based on TSNE Dimensionality
Reduction Method and IGWO-LSSVM Model
Abnormal Status Detection of Catenary Based on TSNE Dimensionality
Reduction Method and IGWO-LSSVM Model
Background:
Catenary is a crucial component of an electrified railroad's traction power supply system.
There is a considerable incidence of abnormal status and failures due to prol...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Tracing Hematological Shifts in Pregnancy: How Anemia and Thrombocytopenia Evolve Across Trimesters
Tracing Hematological Shifts in Pregnancy: How Anemia and Thrombocytopenia Evolve Across Trimesters
Abstract
Introduction
Given pregnancy's significant impact on hematological parameters, monitoring these changes across trimesters is crucial. This study aims to evaluate hematolog...
The Effect of Sample Storage on Impedance and Optical Platelet Counts
The Effect of Sample Storage on Impedance and Optical Platelet Counts
Abstract
Introduction: Processing blood samples for full blood count may be delayed for a multitude of reasons. There is little published information on the effect o...

