Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Integrilin Dose Optimization Using Cone Plate Analyzer – What Have We Learned Thus Far

View through CrossRef
<i>Objectives:</i> To assess platelet inhibition by cone and plate analyzer (CPA) in patients with acute coronary syndromes (ACS) receiving eptifibatide (Integrilin). <i>Background:</i> With the current use of glycoprotein IIb/IIIa (GP-IIb/IIIa) inhibitors during ACS and percutaneous coronary interventions (PCI), the need to measure platelet activity and optimize dosing became apparent. CPA is a novel technique to assess platelet activity in high shear stress conditions, mimicking arterial flow. <i>Method:</i> 40 consecutive patients with ACS received eptifibatide [2 intravenous boluses (180 µg/kg each) spaced 10 min apart, and subsequently a maintenance drip (2 µg/kg/min)]. All patients received aspirin, clopidogrel and unfractionated heparin or enoxaparin in conventional doses. Blood was obtained at baseline, 30 min and 3 h, after eptifibatide initiation, and was sent out for CPA core lab, blinded to patient therapy, characteristics, and sampling time. <i>Results:</i> At 30 min and 3 h only 45 and 60% of patients, respectively, reached GP-IIb/IIIa blockade of ≧95%. 25 and 15%, respectively, had <85% GP-IIb/IIIa blockade. No demographic, clinical, or laboratory predictors for eptifibatide resistance could be identified. <i>Conclusion:</i> <85% GP-IIb/IIIa blockade occurs in a high proportion of patients with ACS treated with eptifibatide. The clinical significance of this phenomenon, and the optimal way to assess and treat it warrant additional research. It is essential, however, to measure platelet activity or GP-IIb/IIIa occupancy in response to therapy, since no demographic, clinical, and laboratory predictors of eptifibatide refractoriness can be identified at this time at the bedside.
Title: Integrilin Dose Optimization Using Cone Plate Analyzer – What Have We Learned Thus Far
Description:
<i>Objectives:</i> To assess platelet inhibition by cone and plate analyzer (CPA) in patients with acute coronary syndromes (ACS) receiving eptifibatide (Integrilin).
<i>Background:</i> With the current use of glycoprotein IIb/IIIa (GP-IIb/IIIa) inhibitors during ACS and percutaneous coronary interventions (PCI), the need to measure platelet activity and optimize dosing became apparent.
CPA is a novel technique to assess platelet activity in high shear stress conditions, mimicking arterial flow.
<i>Method:</i> 40 consecutive patients with ACS received eptifibatide [2 intravenous boluses (180 µg/kg each) spaced 10 min apart, and subsequently a maintenance drip (2 µg/kg/min)].
All patients received aspirin, clopidogrel and unfractionated heparin or enoxaparin in conventional doses.
Blood was obtained at baseline, 30 min and 3 h, after eptifibatide initiation, and was sent out for CPA core lab, blinded to patient therapy, characteristics, and sampling time.
<i>Results:</i> At 30 min and 3 h only 45 and 60% of patients, respectively, reached GP-IIb/IIIa blockade of ≧95%.
25 and 15%, respectively, had <85% GP-IIb/IIIa blockade.
No demographic, clinical, or laboratory predictors for eptifibatide resistance could be identified.
<i>Conclusion:</i> <85% GP-IIb/IIIa blockade occurs in a high proportion of patients with ACS treated with eptifibatide.
The clinical significance of this phenomenon, and the optimal way to assess and treat it warrant additional research.
It is essential, however, to measure platelet activity or GP-IIb/IIIa occupancy in response to therapy, since no demographic, clinical, and laboratory predictors of eptifibatide refractoriness can be identified at this time at the bedside.

Related Results

Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams
Accelerating and improving radiochromic film calibration by utilizing the dose ratio in photon and proton beams
AbstractPurposeRadiochromic films are versatile 2D dosimeters with high‐resolution and near tissue equivalence. To assure high precision and accuracy, a time‐consuming calibration ...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Study on Near-Net Forming Technology for Stepped Shaft by Cross-Wedge Rolling Based on Variable Cone Angle Billets
Study on Near-Net Forming Technology for Stepped Shaft by Cross-Wedge Rolling Based on Variable Cone Angle Billets
Considering problems about concaves at the stepped shaft ends, this paper established the plastic flow kinetic theories about metal deforming during the cross-wedge rolling (CWR) p...
A 40-Foot Static Cone Penetrometer
A 40-Foot Static Cone Penetrometer
Abstract The Navy needs a lightweight device for testing seafloor soils to sub bottom depths of 12 meters in water depths to 60 meters. To meet this need a quasis...
Performance of tri-tubular conical energy absorber under axial compression
Performance of tri-tubular conical energy absorber under axial compression
Quasi static axial compression loading on tri-tubular cone (TC) has been carried out using LS-DYNA finite element analysis method. Tri-tubular cones of three arrangements; the firs...

Back to Top