BackgroundElectroencephalography (EEG) is widely used to monitor critically ill patients. However, EEG interpretation requires the presence of an experienced neurophysiologist and is time-consuming. Aim of this study was to evaluate whether parameters derived from an automated pupillometer (AP) might help to assess the degree of cerebral dysfunction in critically ill patients.MethodsProspective study conducted in the Department of Intensive Care of Erasme University Hospital in Brussels, Belgium. Pupillary assessments were performed using the AP in three subgroups of patients, concomitantly monitored with continuous EEG: “anoxic brain injury”, “Non-anoxic brain injury” and “other diseases”. An independent neurologist blinded to patient's history and AP results scored the degree of encephalopathy and reactivity on EEG using a standardized scale. The mean value of Neurologic Pupil Index (NPi), pupillary size, constriction rate, constriction and dilation velocity (CV and DV) and latency for both eyes, obtained using the NPi®-200 (Neuroptics, Laguna Hills, CA, USA), were reported.ResultsWe included 214 patients (mean age 60 years, 55% male). EEG tracings were categorized as: mild (n = 111, 52%), moderate (n = 65, 30%) or severe (n = 16, 8%) encephalopathy; burst-suppression (n = 19, 9%) or suppression background (n = 3, 1%); a total of 38 (18%) EEG were classified as “unreactive”. We found a significant difference in all pupillometry variables among different EEG categories. Moreover, an unreactive EEG was associated with lower NPi, pupil size, pupillary reactivity, CV and DV and a higher latency than reactive recordings. Low DV (Odds ratio 0.020 [95% confidence intervals 0.002–0.163]; p < 0.01) was independently associated with an unreactive EEG, together with the use of analgesic/sedative drugs and high lactate concentrations. In particular, DV values had an area under the curve (AUC) of 0.86 [0.79–0.92; p < 0.01] to predict the presence of unreactive EEG. In subgroups analyses, AUC of DV to predict unreactive EEG was lower (0.72 [0.56–0.87]; p < 0.01) in anoxic brain injury than Non-anoxic brain injury (0.92 [0.85–1.00]; p < 0.01) and other diseases (0.96 [0.90–1.00]; p < 0.01).ConclusionsThis study suggests that low DV measured by the AP might effectively identify an unreactive EEG background, in particular in critically ill patients without anoxic brain injury.
Frontiers Media SA
Title: Automated Pupillometry for Prediction of Electroencephalographic Reactivity in Critically Ill Patients: A Prospective Cohort Study
Description:
BackgroundElectroencephalography (EEG) is widely used to monitor critically ill patients.
However, EEG interpretation requires the presence of an experienced neurophysiologist and is time-consuming.
Aim of this study was to evaluate whether parameters derived from an automated pupillometer (AP) might help to assess the degree of cerebral dysfunction in critically ill patients.
MethodsProspective study conducted in the Department of Intensive Care of Erasme University Hospital in Brussels, Belgium.
Pupillary assessments were performed using the AP in three subgroups of patients, concomitantly monitored with continuous EEG: “anoxic brain injury”, “Non-anoxic brain injury” and “other diseases”.
An independent neurologist blinded to patient's history and AP results scored the degree of encephalopathy and reactivity on EEG using a standardized scale.
The mean value of Neurologic Pupil Index (NPi), pupillary size, constriction rate, constriction and dilation velocity (CV and DV) and latency for both eyes, obtained using the NPi®-200 (Neuroptics, Laguna Hills, CA, USA), were reported.
ResultsWe included 214 patients (mean age 60 years, 55% male).
EEG tracings were categorized as: mild (n = 111, 52%), moderate (n = 65, 30%) or severe (n = 16, 8%) encephalopathy; burst-suppression (n = 19, 9%) or suppression background (n = 3, 1%); a total of 38 (18%) EEG were classified as “unreactive”.
We found a significant difference in all pupillometry variables among different EEG categories.
Moreover, an unreactive EEG was associated with lower NPi, pupil size, pupillary reactivity, CV and DV and a higher latency than reactive recordings.
Low DV (Odds ratio 0.
020 [95% confidence intervals 0.
002–0.
163]; p < 0.
01) was independently associated with an unreactive EEG, together with the use of analgesic/sedative drugs and high lactate concentrations.
In particular, DV values had an area under the curve (AUC) of 0.
86 [0.
79–0.
92; p < 0.
01] to predict the presence of unreactive EEG.
In subgroups analyses, AUC of DV to predict unreactive EEG was lower (0.
72 [0.
56–0.
87]; p < 0.
01) in anoxic brain injury than Non-anoxic brain injury (0.
92 [0.
85–1.
00]; p < 0.
01) and other diseases (0.
96 [0.
90–1.
00]; p < 0.
01).
ConclusionsThis study suggests that low DV measured by the AP might effectively identify an unreactive EEG background, in particular in critically ill patients without anoxic brain injury.
Related Results
PupillOmetry for preDIction of DeliriUM in ICU (PODIUM): protocol for a prospective multicentre cohort study
PupillOmetry for preDIction of DeliriUM in ICU (PODIUM): protocol for a prospective multicentre cohort study
Introduction
Delirium is a severe complication that is associated with short-term adverse events, prolonged hospital stay and neurological sequelae in survivors...
Predicting the Prognosis of Diffuse Axonal Injury Using Automated Pupillometry
Predicting the Prognosis of Diffuse Axonal Injury Using Automated Pupillometry
Abstract
Background Although previous studies have reported various predictive indicators of diffuse axonal injury (DAI), a consensus regarding the gold-standard predictive...
Correlation Between Electroencephalography and Automated Pupillometry in Critically Ill Patients: A Pilot Study
Correlation Between Electroencephalography and Automated Pupillometry in Critically Ill Patients: A Pilot Study
Background:
Electroencephalography (EEG) is widely used in the monitoring of critically ill comatose patients, but its interpretation is not straightforward. The aim of...
The Hidden Problem of Cross-Reactivity: Challenges in HIV Testing During the COVID-19 Era: A Systematic Review
The Hidden Problem of Cross-Reactivity: Challenges in HIV Testing During the COVID-19 Era: A Systematic Review
Abstract
Introduction
Human immunodeficiency virus (HIV) and Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV2) surface glycoproteins, including shared epitope motifs, sho...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract
Introduction
Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
Trends in Research Related to Pupillometry From 1999 to 2025: A Bibliometric and Visualized Analysis
Trends in Research Related to Pupillometry From 1999 to 2025: A Bibliometric and Visualized Analysis
Objective: Pupillometry is a noninvasive method which measures changes in the size of the pupil intending to study cognitive processes and identify networks that are related to spe...
Biomarkers in critically ill patients
Biomarkers in critically ill patients
We investigated whether biomarkers could (1) improve early diagnosis of sepsis (2) predict prognosis in patients with pneumonia and aneurysmal subarachnoid hemorrhage, (3) predict ...
Reproducibility of Ocular Biometry and Pupillometry with the Aladdin HW2.0 Optical Low-Coherence Interferometer
Reproducibility of Ocular Biometry and Pupillometry with the Aladdin HW2.0 Optical Low-Coherence Interferometer
Objective: The purpose of the study was to evaluate the reproducibility of ocular biometry and pupillometry with the Aladdin HW2.0 (Topcon, Tokyo, Japan) in patients with cataracts...