Background:
Electroencephalography (EEG) is widely used in the monitoring of critically ill comatose patients, but its interpretation is not straightforward. The aim of this study was to evaluate whether there is a correlation between EEG background pattern/reactivity to stimuli and automated pupillometry in critically ill patients.
Methods:
Prospective assessment of pupillary changes to light stimulation was obtained using an automated pupillometry (NeuroLight Algiscan, ID-MED, Marseille, France) in 60 adult patients monitored with continuous EEG. The degree of encephalopathy and EEG reactivity were scored by 3 independent neurophysiologists blinded to the patient’s history. The median values of baseline pupil size, pupillary constriction, constriction velocity, and latency were collected for both eyes. To assess sensitivity and specificity, we calculated areas under the receiver-operating characteristic curve.
Results:
The degree of encephalopathy assessed by EEG was categorized as mild (42%), moderate (37%), severe (10%) or suppression-burst/suppression (12%); a total of 47/60 EEG recordings were classified as “reactive.” There was a significant difference in pupillary size, constriction rate, and constriction velocity, but not latency, among the different EEG categories of encephalopathy. Similarly, reactive EEG tracings were associated with greater pupil size, pupillary constriction rate, and constriction velocity compared with nonreactive recordings; there were no significant differences in latency. Pupillary constriction rate values had an area under the curve of 0.83 to predict the presence of severe encephalopathy or suppression-burst/suppression, with a pupillary constriction rate of < 20% having a sensitivity of 85% and a specificity of 79%.
Conclusions:
Automated pupillometry can contribute to the assessment of cerebral dysfunction in critically ill patients.
Ovid Technologies (Wolters Kluwer Health)
Title: Correlation Between Electroencephalography and Automated Pupillometry in Critically Ill Patients: A Pilot Study
Description:
Background:
Electroencephalography (EEG) is widely used in the monitoring of critically ill comatose patients, but its interpretation is not straightforward.
The aim of this study was to evaluate whether there is a correlation between EEG background pattern/reactivity to stimuli and automated pupillometry in critically ill patients.
Methods:
Prospective assessment of pupillary changes to light stimulation was obtained using an automated pupillometry (NeuroLight Algiscan, ID-MED, Marseille, France) in 60 adult patients monitored with continuous EEG.
The degree of encephalopathy and EEG reactivity were scored by 3 independent neurophysiologists blinded to the patient’s history.
The median values of baseline pupil size, pupillary constriction, constriction velocity, and latency were collected for both eyes.
To assess sensitivity and specificity, we calculated areas under the receiver-operating characteristic curve.
Results:
The degree of encephalopathy assessed by EEG was categorized as mild (42%), moderate (37%), severe (10%) or suppression-burst/suppression (12%); a total of 47/60 EEG recordings were classified as “reactive.
” There was a significant difference in pupillary size, constriction rate, and constriction velocity, but not latency, among the different EEG categories of encephalopathy.
Similarly, reactive EEG tracings were associated with greater pupil size, pupillary constriction rate, and constriction velocity compared with nonreactive recordings; there were no significant differences in latency.
Pupillary constriction rate values had an area under the curve of 0.
83 to predict the presence of severe encephalopathy or suppression-burst/suppression, with a pupillary constriction rate of < 20% having a sensitivity of 85% and a specificity of 79%.
Conclusions:
Automated pupillometry can contribute to the assessment of cerebral dysfunction in critically ill patients.
Related Results
PupillOmetry for preDIction of DeliriUM in ICU (PODIUM): protocol for a prospective multicentre cohort study
PupillOmetry for preDIction of DeliriUM in ICU (PODIUM): protocol for a prospective multicentre cohort study
Introduction
Delirium is a severe complication that is associated with short-term adverse events, prolonged hospital stay and neurological sequelae in survivors...
Predicting the Prognosis of Diffuse Axonal Injury Using Automated Pupillometry
Predicting the Prognosis of Diffuse Axonal Injury Using Automated Pupillometry
Abstract
Background Although previous studies have reported various predictive indicators of diffuse axonal injury (DAI), a consensus regarding the gold-standard predictive...
Electroencephalography Predicts Poor and Good Outcomes After Cardiac Arrest: A Two-Center Study*
Electroencephalography Predicts Poor and Good Outcomes After Cardiac Arrest: A Two-Center Study*
Objective:The prognostic role of electroencephalography during and after targeted temperature management in postcardiac arrest patients, relatively to other predictors, is incomple...
Trends in Research Related to Pupillometry From 1999 to 2025: A Bibliometric and Visualized Analysis
Trends in Research Related to Pupillometry From 1999 to 2025: A Bibliometric and Visualized Analysis
Objective: Pupillometry is a noninvasive method which measures changes in the size of the pupil intending to study cognitive processes and identify networks that are related to spe...
Biomarkers in critically ill patients
Biomarkers in critically ill patients
We investigated whether biomarkers could (1) improve early diagnosis of sepsis (2) predict prognosis in patients with pneumonia and aneurysmal subarachnoid hemorrhage, (3) predict ...
Reproducibility of Ocular Biometry and Pupillometry with the Aladdin HW2.0 Optical Low-Coherence Interferometer
Reproducibility of Ocular Biometry and Pupillometry with the Aladdin HW2.0 Optical Low-Coherence Interferometer
Objective: The purpose of the study was to evaluate the reproducibility of ocular biometry and pupillometry with the Aladdin HW2.0 (Topcon, Tokyo, Japan) in patients with cataracts...
MO298: Predictors of Renal Function Recovery in Critically ill Patients With Acute Kidney Injury
MO298: Predictors of Renal Function Recovery in Critically ill Patients With Acute Kidney Injury
Abstract
BACKGROUND AND AIMS
Acute kidney injury (AKI) is a frequent and serious complication in critically ill patients admitte...
Clinical characteristics and risk factors for severe-critically ill COVID-19 adult patients in Jiangsu, China: a multiple-centered, retrospective study
Clinical characteristics and risk factors for severe-critically ill COVID-19 adult patients in Jiangsu, China: a multiple-centered, retrospective study
Abstract
Background A number of reports have documented the clinical characteristics of patients with severe coronavirus disease 2019 (COVID-19) in Wuhan. Clinical features...