Javascript must be enabled to continue!
Rotator Cuff Repair: The Compression SpeedBridge Technique
View through CrossRef
Background:
While rotator cuff repair has generally produced good to excellent outcomes, re-tear rates remain variable, with rates ranging from 20% to 50%. The ideal rotator cuff repair includes 3 main components: restoration of the humeral footprint contact area, appropriate compression of the tendon to the humeral footprint, and minimal motion at the bone-tendon interface until bone-tendon healing is completed. This video takes a well-established knotless double-row technique for rotator cuff repair and augments it with a modification to promote additional compression of the medial row tendon to the humeral footprint.
Indications:
This compression SpeedBridge technique is indicated for repair of T-type rotator cuff tears involving the supraspinatus and infraspinatus tendons in patients that have failed conservative management, including physical therapy, activity modification, and corticosteroid injections. This technique can also be applied to U-shaped or L-shaped tears by removing the initial step, which involves side-to-side repair of the “T” portion of the T-type tear. Of note, findings such as advanced muscle atrophy (Goutalier III/IV) and advanced glenohumeral arthritis are concerning for irreparable tears and may be contraindications for surgical repair.
Technique Description:
With the patient in the lateral decubitus position, a diagnostic arthroscopy is performed, the rotator cuff tear is debrided, and the footprint prepared. Two side-to-side stitches are placed to repair the “T” portion of the tear. The medial row anchors are then sequentially placed, and the pre-loaded sutures are passed through the tendon in 4 sequential locations in specific fashion. After placement of looped sutures in the anterior and posterior rotator cables, the passed sutures are then incorporated into the lateral row anchors. The medial row compression is provided by shuttling previously placed compression stitches through the knotless mechanism in the medial row anchors and terminally tensioned.
Results:
This technique provides additional medial row compression to an already-established knotless double-row rotator cuff repair technique to facilitate improved bone-tendon healing and construct strength.
Discussion/Conclusion:
The compression SpeedBridge technique is a unique method to apply additional medial row compression to a double-row rotator cuff repair.
Patient Consent Disclosure Statement:
The author(s) attests that consent has been obtained from any patient(s) appearing in this publication. If the individual may be identifiable, the author(s) has included a statement of release or other written form of approval from the patient(s) with this submission for publication.
SAGE Publications
Title: Rotator Cuff Repair: The Compression SpeedBridge Technique
Description:
Background:
While rotator cuff repair has generally produced good to excellent outcomes, re-tear rates remain variable, with rates ranging from 20% to 50%.
The ideal rotator cuff repair includes 3 main components: restoration of the humeral footprint contact area, appropriate compression of the tendon to the humeral footprint, and minimal motion at the bone-tendon interface until bone-tendon healing is completed.
This video takes a well-established knotless double-row technique for rotator cuff repair and augments it with a modification to promote additional compression of the medial row tendon to the humeral footprint.
Indications:
This compression SpeedBridge technique is indicated for repair of T-type rotator cuff tears involving the supraspinatus and infraspinatus tendons in patients that have failed conservative management, including physical therapy, activity modification, and corticosteroid injections.
This technique can also be applied to U-shaped or L-shaped tears by removing the initial step, which involves side-to-side repair of the “T” portion of the T-type tear.
Of note, findings such as advanced muscle atrophy (Goutalier III/IV) and advanced glenohumeral arthritis are concerning for irreparable tears and may be contraindications for surgical repair.
Technique Description:
With the patient in the lateral decubitus position, a diagnostic arthroscopy is performed, the rotator cuff tear is debrided, and the footprint prepared.
Two side-to-side stitches are placed to repair the “T” portion of the tear.
The medial row anchors are then sequentially placed, and the pre-loaded sutures are passed through the tendon in 4 sequential locations in specific fashion.
After placement of looped sutures in the anterior and posterior rotator cables, the passed sutures are then incorporated into the lateral row anchors.
The medial row compression is provided by shuttling previously placed compression stitches through the knotless mechanism in the medial row anchors and terminally tensioned.
Results:
This technique provides additional medial row compression to an already-established knotless double-row rotator cuff repair technique to facilitate improved bone-tendon healing and construct strength.
Discussion/Conclusion:
The compression SpeedBridge technique is a unique method to apply additional medial row compression to a double-row rotator cuff repair.
Patient Consent Disclosure Statement:
The author(s) attests that consent has been obtained from any patient(s) appearing in this publication.
If the individual may be identifiable, the author(s) has included a statement of release or other written form of approval from the patient(s) with this submission for publication.
Related Results
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Differential Diagnosis of Neurogenic Thoracic Outlet Syndrome: A Review
Abstract
Thoracic outlet syndrome (TOS) is a complex and often overlooked condition caused by the compression of neurovascular structures as they pass through the thoracic outlet. ...
A CLINICAL STUDY OF FUNCTIONAL OUTCOME OF ALLARTHROSCOPIC ROTATOR CUFF REPAIR
A CLINICAL STUDY OF FUNCTIONAL OUTCOME OF ALLARTHROSCOPIC ROTATOR CUFF REPAIR
Introduction: Rotator cuff tears are among the most common shoulder injuries and are usually accompanied by shoulder pain, disability and
dysfunction over the past decade rotator c...
Does fat infiltration of the rotator cuff muscles contribute to 8increased hidden blood loss (HBL) and other risk factors during arthroscopic rotator cuff repair for rotator cuff injuries?
Does fat infiltration of the rotator cuff muscles contribute to 8increased hidden blood loss (HBL) and other risk factors during arthroscopic rotator cuff repair for rotator cuff injuries?
Abstract
Objective
To compare hidden blood loss (HBL) among patients with rotator cuff injuries undergoing arthroscopic rotator cuff repair who exhibit varying degr...
Traumatic Inferior Shoulder Dislocation with Posterior Cord Brachial Plexopathy: A Case Report
Traumatic Inferior Shoulder Dislocation with Posterior Cord Brachial Plexopathy: A Case Report
Introduction: Inferior glenohumeral dislocations are rare injuries, comprising <1% of shoulder dislocations. While their presentation is rare, these injuries commonly result in ...
Arthroscopic cuff repair: footprint remnant preserving versus debriding rotator cuff repair of transtendinous rotator cuff tears with remnant cuff
Arthroscopic cuff repair: footprint remnant preserving versus debriding rotator cuff repair of transtendinous rotator cuff tears with remnant cuff
Abstract
Background
In transtendinous full thickness rotator cuff tears (FTRCT) with remnant cuff, conventionally, cuff remnant of the greater tuber...
Assessment of rotator cuff tears among bodybuilders in Lahore
Assessment of rotator cuff tears among bodybuilders in Lahore
Background: The current was performed on bodybuilders to see the shoulder rotator cuff injuries among them. A bodybuilder is a person who strengthens and enlarges the muscles of th...
Exploring Recent Advancements in Rotator Cuff Injury Rehabilitation: A Narrative Review
Exploring Recent Advancements in Rotator Cuff Injury Rehabilitation: A Narrative Review
Rotator cuff injuries are prevalent musculoskeletal injuries that may impair quality of life and function. This narrative review covers current rotator cuff injury rehabilitation b...
A PROSPECTIVE STUDY OF FUNCTIONAL OUTCOME AFTER ROTATOR CUFF REPAIR FOR LARGE ROTATOR CUFF TEARS FOLLOWING ARTHROSCOPIC DOUBLE ROW -TRANSOSSEOUS EQUIVALENT REPAIR V/S SINGLE ROW ROTATOR CUFF REPAIR
A PROSPECTIVE STUDY OF FUNCTIONAL OUTCOME AFTER ROTATOR CUFF REPAIR FOR LARGE ROTATOR CUFF TEARS FOLLOWING ARTHROSCOPIC DOUBLE ROW -TRANSOSSEOUS EQUIVALENT REPAIR V/S SINGLE ROW ROTATOR CUFF REPAIR
Tears of the rotator cuff tendons remain a common source of pain and disability among the adult population. Age appears to be the most common
aetiology, with 25% of individuals in ...

