A compressor blade failure was experienced on a 69 MW gas turbine of a combined cycle (C.C.) unit after four years operation since its last overhaul (January 2005). The unit accumulated 27,000 service hours and 97 start-ups since the last overhaul. This unit consists of four gas turbine stages and 19 compressor stages and operates at 3600 rpm. In 2006, the unit was equipped with a fogging system at the compressor air inlet duct to increase unit power output during high ambient temperature days (hot days). These fog water nozzles were installed upstream of the compressor inlet air filter without any water filter/catcher before the water spray nozzles. Three unit failure events occurred within a small time period, which caused a forced outage. The first failure occurred in December 2008, a second event in March 2009 and the third event in May 2009. Visual examination carried out after the first failure indicated that the compressor vanes (diaphragms) had cracks in their airfoil initiating at the blade tenons welded to the diaphragm outer shroud at stages 3, 8, 9, 10 and 11. Also, a number of stationary vanes and blades at each stage of the compressor showed foreign object damage (FOD) and fractures at the airfoil. Visual examination performed for the second failure event after 60 unit operating hours indicated that many compressor vanes (diaphragms) and blades had FOD at the airfoil. This was attributed to fractures caused by the fogging system. The water spray carried over in the compressor flow path at high velocity causing the FOD damage. Visual examination completed upon the third failure event after two unit startup attempts indicated damage of compressor stationary vanes and blades, principally at stages 12 to 16, and also stages 17 to 19. The damage consisted of airfoil fracture in the stationary vanes and blades, FOD, blade tip rubbing, and bending of the stationary vanes, blades and diaphragm shrouds. A laboratory evaluation of stationary vane tenon fracture indicated a high cycle fatigue (HCF) failure mechanism, and crack initiation was accelerated by corrosion pitting on blade surfaces due to high humidity air generated by the fogging system. Stationary vane damage was caused by a rotating stall phenomenon, which generates vibratory stress in stationary vanes and blades during unit start-ups. During the third failure event, the stationary vane HCF damage was highly accelerated due to pre-existing partial fractures in the tenons generated during previous failure events which had not been detected by non-destructive tests. Stationary vane and moving blade failure was also influenced by high tenon brittleness in stationary vanes and blades generated during manufacture by welding the diaphragms, and repair welding the blades without adequate post-weld heat treatment (stress relieving). A compressor stationary vane and blade failure evaluation was completed. This investigation included cracked blade metallographic analysis, unit operation parameter analysis, history-of-events analysis, and crack initiation and propagation analysis. This paper provides an overview of the compressor failure investigation, which led to the identification of the HCF failure mechanism generated by rotating stall during unit start-ups, highly accelerated corrosion generated by the fogging system, and high brittleness in the stationary vanes and blades as the primary contribution to the observed failure.
Title: Failure Evaluation of the Compressor Vanes of Combined Cycle Unit
Description:
A compressor blade failure was experienced on a 69 MW gas turbine of a combined cycle (C.
C.
) unit after four years operation since its last overhaul (January 2005).
The unit accumulated 27,000 service hours and 97 start-ups since the last overhaul.
This unit consists of four gas turbine stages and 19 compressor stages and operates at 3600 rpm.
In 2006, the unit was equipped with a fogging system at the compressor air inlet duct to increase unit power output during high ambient temperature days (hot days).
These fog water nozzles were installed upstream of the compressor inlet air filter without any water filter/catcher before the water spray nozzles.
Three unit failure events occurred within a small time period, which caused a forced outage.
The first failure occurred in December 2008, a second event in March 2009 and the third event in May 2009.
Visual examination carried out after the first failure indicated that the compressor vanes (diaphragms) had cracks in their airfoil initiating at the blade tenons welded to the diaphragm outer shroud at stages 3, 8, 9, 10 and 11.
Also, a number of stationary vanes and blades at each stage of the compressor showed foreign object damage (FOD) and fractures at the airfoil.
Visual examination performed for the second failure event after 60 unit operating hours indicated that many compressor vanes (diaphragms) and blades had FOD at the airfoil.
This was attributed to fractures caused by the fogging system.
The water spray carried over in the compressor flow path at high velocity causing the FOD damage.
Visual examination completed upon the third failure event after two unit startup attempts indicated damage of compressor stationary vanes and blades, principally at stages 12 to 16, and also stages 17 to 19.
The damage consisted of airfoil fracture in the stationary vanes and blades, FOD, blade tip rubbing, and bending of the stationary vanes, blades and diaphragm shrouds.
A laboratory evaluation of stationary vane tenon fracture indicated a high cycle fatigue (HCF) failure mechanism, and crack initiation was accelerated by corrosion pitting on blade surfaces due to high humidity air generated by the fogging system.
Stationary vane damage was caused by a rotating stall phenomenon, which generates vibratory stress in stationary vanes and blades during unit start-ups.
During the third failure event, the stationary vane HCF damage was highly accelerated due to pre-existing partial fractures in the tenons generated during previous failure events which had not been detected by non-destructive tests.
Stationary vane and moving blade failure was also influenced by high tenon brittleness in stationary vanes and blades generated during manufacture by welding the diaphragms, and repair welding the blades without adequate post-weld heat treatment (stress relieving).
A compressor stationary vane and blade failure evaluation was completed.
This investigation included cracked blade metallographic analysis, unit operation parameter analysis, history-of-events analysis, and crack initiation and propagation analysis.
This paper provides an overview of the compressor failure investigation, which led to the identification of the HCF failure mechanism generated by rotating stall during unit start-ups, highly accelerated corrosion generated by the fogging system, and high brittleness in the stationary vanes and blades as the primary contribution to the observed failure.
Related Results
CFD investigation of flow through a centrifugal compressor diffuser with splitter blades
CFD investigation of flow through a centrifugal compressor diffuser with splitter blades
AbstractThe aerodynamic losses in centrifugal compressors are mainly associated with the separated flow on the suction sides of impeller and diffuser vanes. The overall performance...
Root Cause Analysis of the Catastrophic Failure of a Propylene Recycle Compressor
Root Cause Analysis of the Catastrophic Failure of a Propylene Recycle Compressor
Abstract
A 2-section, 6-stage propylene recycle compressor experienced a catastrophic failure that resulted in extensive damage to its internals. The compressor was ...
Study on Internal Flow Characteristics of Hydrocyclone with Guide Vanes
Study on Internal Flow Characteristics of Hydrocyclone with Guide Vanes
Hydrocyclone with guide vanes is one type of swirl flow launching device without energy input. For researching the flow characteristics of that hydrocyclone, the flow distribution ...
Peningkatan Prestasi Belajar Materi Bilangan Berpangkat Melalui Model Discovery Learning
Peningkatan Prestasi Belajar Materi Bilangan Berpangkat Melalui Model Discovery Learning
This research is motivated by the unoptimally the mastery of the material is still not optimal exponential number among learners and implementation Discovery learning in mathematic...
Achieving the Three Dimensions of Mixed Refrigerant Compressor Efficiency
Achieving the Three Dimensions of Mixed Refrigerant Compressor Efficiency
Abstract
Investors in small-scale LNG (SSLNG) face the grave challenge of achieving cost efficiency, operational efficiency, and energy efficiency in the equipment t...
USE OF THE THEORY OF FINITE AUTOMATA FOR SUPERVISION OF THE OPERATION OF THE COMPRESSOR UNIT
USE OF THE THEORY OF FINITE AUTOMATA FOR SUPERVISION OF THE OPERATION OF THE COMPRESSOR UNIT
The purpose of the publication is to develop a methodology for presenting the unit "6 kV compressor-synchronous electric motor" in the form of a finite state machine.
It is hypoth...
The Effects of Wet Compression on Gas Turbine Engine Operating Performance
The Effects of Wet Compression on Gas Turbine Engine Operating Performance
Water, in the liquid or vapor phase, injected at various locations into the gas turbine cycle has frequently been employed to improve engine performance. One such way to improve en...
Multicriteria Optimization of Axial Low Pressure Compressor of Gas Turbine Power Plant
Multicriteria Optimization of Axial Low Pressure Compressor of Gas Turbine Power Plant
The paper shows a method of the gas-dynamic refining of three-stage axial compressor based on the joint usage of mathematical optimization software IOSO and CFD complex NUMECA. The...