Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

CFD investigation of flow through a centrifugal compressor diffuser with splitter blades

View through CrossRef
AbstractThe aerodynamic losses in centrifugal compressors are mainly associated with the separated flow on the suction sides of impeller and diffuser vanes. The overall performance of such compressors can be improved by adding splitter vanes. The present work examines the effect of varying the geometrical location of the splitter vanes in the diffuser on the overall performance of a high-speed centrifugal compressor stage of a small gas turbine. To increase the pressure recovery through the diffuser, two radial sets of vanes are used. The first set of vanes (diffuser-1) is equipped with splitter vanes, placed mid-distance between the main vanes, while the vanes of the second set (diffuser-2) are conventional vanes. Flow through the compressor was simulated using the ANSYS 19 workbench program. Flow characteristics and compressor performance were obtained and analyzed for different circumferential positions of the splitting vanes relative to the main vanes of diffuser-1. The study covered seven positions of the splitter vanes including the original design of the diffuser where the splitter vanes were located at mid-distance between the main vanes. The analysis shows that, at design conditions, selecting the position of the splitter vanes to be nearer to the pressure side of the main vanes improves the stage performance. In the present study, locating the splitters at 33% of the angular distance between the main vanes leads to the best performance, and a significant improvement in the overall stage performance is recorded. The pressure recovery coefficient is raised by about 17%, the pressure ratio is increased by about 1.13%, and the stage efficiency is increased by about 2.01%, compared to the original splitter position. Performance improvement is related to the suppression of the flow separation and the more uniformity of flow. On the contrary, further moving the splitter closer to the main blade, the pressure recovery coefficient is decreased by about 2% than the position of 33% of the angular distance, but still higher than the original position by about 15% and a limited improvement in the compressor performance is noticed. Moving the splitter far out the main blade annihilates the static pressure recovery of the diffuser by about 2:7% compared with the original position. So, for the investigated compressor, the best position of the splitter blade in the circumferential direction, which provides the best stage performance in our parametric analysis, is not necessary to be at the mid-angular distance between the diffuser’s main blades, but it is achieved by moving the splitter to about 33% of the angular distance where the diminished loss from the suppressed flow separation is more prevailing and the instigated friction losses from splitter surfaces are less critical.
Title: CFD investigation of flow through a centrifugal compressor diffuser with splitter blades
Description:
AbstractThe aerodynamic losses in centrifugal compressors are mainly associated with the separated flow on the suction sides of impeller and diffuser vanes.
The overall performance of such compressors can be improved by adding splitter vanes.
The present work examines the effect of varying the geometrical location of the splitter vanes in the diffuser on the overall performance of a high-speed centrifugal compressor stage of a small gas turbine.
To increase the pressure recovery through the diffuser, two radial sets of vanes are used.
The first set of vanes (diffuser-1) is equipped with splitter vanes, placed mid-distance between the main vanes, while the vanes of the second set (diffuser-2) are conventional vanes.
Flow through the compressor was simulated using the ANSYS 19 workbench program.
Flow characteristics and compressor performance were obtained and analyzed for different circumferential positions of the splitting vanes relative to the main vanes of diffuser-1.
The study covered seven positions of the splitter vanes including the original design of the diffuser where the splitter vanes were located at mid-distance between the main vanes.
The analysis shows that, at design conditions, selecting the position of the splitter vanes to be nearer to the pressure side of the main vanes improves the stage performance.
In the present study, locating the splitters at 33% of the angular distance between the main vanes leads to the best performance, and a significant improvement in the overall stage performance is recorded.
The pressure recovery coefficient is raised by about 17%, the pressure ratio is increased by about 1.
13%, and the stage efficiency is increased by about 2.
01%, compared to the original splitter position.
Performance improvement is related to the suppression of the flow separation and the more uniformity of flow.
On the contrary, further moving the splitter closer to the main blade, the pressure recovery coefficient is decreased by about 2% than the position of 33% of the angular distance, but still higher than the original position by about 15% and a limited improvement in the compressor performance is noticed.
Moving the splitter far out the main blade annihilates the static pressure recovery of the diffuser by about 2:7% compared with the original position.
So, for the investigated compressor, the best position of the splitter blade in the circumferential direction, which provides the best stage performance in our parametric analysis, is not necessary to be at the mid-angular distance between the diffuser’s main blades, but it is achieved by moving the splitter to about 33% of the angular distance where the diminished loss from the suppressed flow separation is more prevailing and the instigated friction losses from splitter surfaces are less critical.

Related Results

Optimization of Centrifugal Compressor Splitter Blades Design Based on Regression Kriging Algorithm
Optimization of Centrifugal Compressor Splitter Blades Design Based on Regression Kriging Algorithm
Abstract Centrifugal compressors are widely used in ships, automobiles, aerospace and other fields. At present, the centrifugal compressor is usually designed with splitter...
Centrifugal Compressor Design Considerations
Centrifugal Compressor Design Considerations
Initial design considerations of centrifugal compressor are commonly performed with experience base, although computer technology and numerical methods had made significantly progr...
Simulation of Shrouded Wind Turbine Performance
Simulation of Shrouded Wind Turbine Performance
<p>The objective of this research is to enhance the diffuser parameters of shrouded Wind Turbine (Diffuser Augmented Wind Turbine DAWT). The study investigates different para...
Numerical Investigation of Diffuser Flow Field and Rotating Stall in a Centrifugal Compressor With Vaned Diffuser
Numerical Investigation of Diffuser Flow Field and Rotating Stall in a Centrifugal Compressor With Vaned Diffuser
The diffuser rotating stall in a centrifugal compressor with vaned diffuser is one of important unsteady flow phenomena, which limits the operating range of the compressor. In this...
Failure Evaluation of the Compressor Vanes of Combined Cycle Unit
Failure Evaluation of the Compressor Vanes of Combined Cycle Unit
A compressor blade failure was experienced on a 69 MW gas turbine of a combined cycle (C.C.) unit after four years operation since its last overhaul (January 2005). The unit accumu...
Change in Liquid Splitter Operation—Averted Environmental Flaring
Change in Liquid Splitter Operation—Averted Environmental Flaring
Abstract Liquid Splitter (a tray type Stripper Column) is one of the key process units in the LNG/LPG plant which handles liquid hydrocarbons coming from Feed Gas Co...
Unsteady Flow in a Turbocharger Centrifugal Compressor: 3D-CFD Simulation, Impeller Blade Vibration and Vaned Diffuser-Volute Interaction
Unsteady Flow in a Turbocharger Centrifugal Compressor: 3D-CFD Simulation, Impeller Blade Vibration and Vaned Diffuser-Volute Interaction
Experimental investigations on a single stage centrifugal compressor with radial inlet duct showed that measured alternating strains of the rotating blades depend considerably on t...
Effects of Airflow Deflection Angle in Diffuser on Forced Response Caused by Impeller-diffuser Interaction in Centrifugal Compressors
Effects of Airflow Deflection Angle in Diffuser on Forced Response Caused by Impeller-diffuser Interaction in Centrifugal Compressors
Aeroelasticity has always been a significant issue of compressors. Impeller-diffuser interaction (IDI) produces periodic aerodynamic excitation which forces the blades to vibrate i...

Back to Top