Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Effect of Vortex Generator Angle on Fin and Tube Heat Exchanger

View through CrossRef
In refrigeration systems, a common installed component is the fin and tube heat exchanger. The fluid that passes through the fins has lower thermal conductivity than the fluid flowing inside the tubes, resulting in high thermal resistance. To address this problem, a vortex generator was introduced in the design of the fin and tube heat exchanger. This passive approach aims to improve heat transfer within heat exchangers by promoting the mixing of hot and cold fluids, thereby improving the convection coefficient. This study seeks to investigate the impact of the longitudinal vortex on pressure drop and the increase in the convection coefficient. Through numerical simulations, the study examined seven rows of tubes at angles of attack of 5°, 10°, and 15°. The vortex generator that used in this study are rectangular winglet pairs (RWP), concave rectangular winglet pairs (CRWP), and convex rectangular winglet pairs (CRWP). It was concluded that using Concave Rectangular Winglet Pairs (CRWP) as the vortex generator shape at a 15° angle of attack led to the highest difference in convection coefficient, reaching 154.13% of the baseline case with a Reynolds value of 662. Furthermore, the use of a Rectangular Winglet Pairs (RWP) vortex generator at a 5° angle of attack and a Reynolds value of 284 resulted in the least impact on pressure drop, with an increase of 45.29% compared to the baseline case.
Title: Effect of Vortex Generator Angle on Fin and Tube Heat Exchanger
Description:
In refrigeration systems, a common installed component is the fin and tube heat exchanger.
The fluid that passes through the fins has lower thermal conductivity than the fluid flowing inside the tubes, resulting in high thermal resistance.
To address this problem, a vortex generator was introduced in the design of the fin and tube heat exchanger.
This passive approach aims to improve heat transfer within heat exchangers by promoting the mixing of hot and cold fluids, thereby improving the convection coefficient.
This study seeks to investigate the impact of the longitudinal vortex on pressure drop and the increase in the convection coefficient.
Through numerical simulations, the study examined seven rows of tubes at angles of attack of 5°, 10°, and 15°.
The vortex generator that used in this study are rectangular winglet pairs (RWP), concave rectangular winglet pairs (CRWP), and convex rectangular winglet pairs (CRWP).
It was concluded that using Concave Rectangular Winglet Pairs (CRWP) as the vortex generator shape at a 15° angle of attack led to the highest difference in convection coefficient, reaching 154.
13% of the baseline case with a Reynolds value of 662.
Furthermore, the use of a Rectangular Winglet Pairs (RWP) vortex generator at a 5° angle of attack and a Reynolds value of 284 resulted in the least impact on pressure drop, with an increase of 45.
29% compared to the baseline case.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Stability and dynamics of geophysical neutral vortices
Stability and dynamics of geophysical neutral vortices
(English) Mesoscale and submesoscale vortical structures are ubiquitous in the ocean and atmosphere. Most of these vortices are long-lived with a lifetime of several months. They o...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Investigation of vortex in pump sump by V3V measurements
Investigation of vortex in pump sump by V3V measurements
Abstract The aims, scope and conclusions of the paper must be in a self-contained abstract of a single paragraph with 60-120 words. The abstract must be informative ...
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Parametric Modeling and Economic Analysis of a 2MWth 3-Stream sCO2 Heat Exchanger
Abstract This paper presents the design and cost optimization of a novel 2MWth 3-stream sCO2 plate-fin heat exchanger. This heat exchanger design is unique in that i...
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Kaji efisiensi temperatur penukar panas dengan variasi aliran untuk aplikasi pengering
Abstrak Heat exchanger atau alat penukar panas adalah alat-alat yang digunakan untuk mengubah temperatur fluida atau mengubah fasa fluida dengan cara mempertukarkan panasnya dengan...
ANALYSIS OF DENICKELIFICATION PHENOMENON ON HEAT EXCHANGER TUBE
ANALYSIS OF DENICKELIFICATION PHENOMENON ON HEAT EXCHANGER TUBE
DeNickelification is common phenomenon which occurs for alloy metal containing sufficient amounts of Nickel when it is exposed at high temperature in long time periode. One of comp...

Back to Top