Javascript must be enabled to continue!
PERBEDAAN INFORMASI CITRA ANATOMI SEKUEN DIFFUSION WEIGHTED IMAGING (DWI) ANTARA PENGGUNAAN PROPELLER DENGAN TANPA PROPELLER PADA PEMERIKSAAN MRI BRAIN DENGAN KASUS STROKE
View through CrossRef
Background: Stroke is a brain disease where an acute nerve function is occurred due to the cerebral vascular disorders. To establish a diagnosis the stroke, it can be identified by employing the Diffusion Weighted Imaging (DWI) sequence in the MRI examination. Artifacts still exist on the MRI image which in turn reduce the resolution when using the DWI sequence. Adding the PROPELLER data acquisition method in the DWI sequence possibly improves the quality of brain images. The purpose of this study is to know the difference on the quality of anatomical image information between the DWI sequences with PROPELLER and without PROPELLER methods, and to determine adequate anatomical image appearance that created in amongst of the two methods, specifically for the stroke disease.Methods: this research is quantitative research with experimental approach. This study was conducted using MRI 1.5 T at Bethesda Hospital Yogyakarta. Data were 16 images from 8 patients using DWI sequences using PROPELLER without PROPELLER on MRI Brain examination with stroke. The results of the image were evaluated on 7 criteria: cortex cerebri, basal ganglia, thalamus, pons, cerebellum, stroke (infarction) and artifacts using questionnaires given to 3 respondents. Data analysis was done by Wilcoxon test to know the difference of anatomical image information on DWI sequence using PROPELLER without PROPELLER and to know better anatomical image information from both sequences seen from mean rank value.Results: The results shown, there is a significant difference on the quality of anatomical image information and the artifacts between the use of DWI sequence with and without PROPELLER methods ( 0.05). Based on the mean rank results, the DWI PROPELLER sequence has a higher mean rank value 4.50 compared to the DWI sequence without PROPELLER 0.00.Conclusions: The DWI PROPELLER sequence has better image results compared to the DWI sequence without PROPELLER.
Poltekkes Kemenkes Semarang
Title: PERBEDAAN INFORMASI CITRA ANATOMI SEKUEN DIFFUSION WEIGHTED IMAGING (DWI) ANTARA PENGGUNAAN PROPELLER DENGAN TANPA PROPELLER PADA PEMERIKSAAN MRI BRAIN DENGAN KASUS STROKE
Description:
Background: Stroke is a brain disease where an acute nerve function is occurred due to the cerebral vascular disorders.
To establish a diagnosis the stroke, it can be identified by employing the Diffusion Weighted Imaging (DWI) sequence in the MRI examination.
Artifacts still exist on the MRI image which in turn reduce the resolution when using the DWI sequence.
Adding the PROPELLER data acquisition method in the DWI sequence possibly improves the quality of brain images.
The purpose of this study is to know the difference on the quality of anatomical image information between the DWI sequences with PROPELLER and without PROPELLER methods, and to determine adequate anatomical image appearance that created in amongst of the two methods, specifically for the stroke disease.
Methods: this research is quantitative research with experimental approach.
This study was conducted using MRI 1.
5 T at Bethesda Hospital Yogyakarta.
Data were 16 images from 8 patients using DWI sequences using PROPELLER without PROPELLER on MRI Brain examination with stroke.
The results of the image were evaluated on 7 criteria: cortex cerebri, basal ganglia, thalamus, pons, cerebellum, stroke (infarction) and artifacts using questionnaires given to 3 respondents.
Data analysis was done by Wilcoxon test to know the difference of anatomical image information on DWI sequence using PROPELLER without PROPELLER and to know better anatomical image information from both sequences seen from mean rank value.
Results: The results shown, there is a significant difference on the quality of anatomical image information and the artifacts between the use of DWI sequence with and without PROPELLER methods ( 0.
05).
Based on the mean rank results, the DWI PROPELLER sequence has a higher mean rank value 4.
50 compared to the DWI sequence without PROPELLER 0.
00.
Conclusions: The DWI PROPELLER sequence has better image results compared to the DWI sequence without PROPELLER.
Related Results
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct
Introduction
Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
INFORMASI CITRA MRI KNEE JOINT KASUS RUPTURE ACL SEKUEN PD FATSAT DAN DIXON
INFORMASI CITRA MRI KNEE JOINT KASUS RUPTURE ACL SEKUEN PD FATSAT DAN DIXON
Rupture Anterior Cruciate Ligament adalah kondisi dimana ligament pada sendi lutut mengalami robek, yang dapat disebabkan oleh trauma. Untuk mengoptimalkan anatomi dan patologi mak...
Brain Organoids, the Path Forward?
Brain Organoids, the Path Forward?
Photo by Maxim Berg on Unsplash
INTRODUCTION
The brain is one of the most foundational parts of being human, and we are still learning about what makes humans unique. Advancements ...
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review Anna Tri Wahyuni1), Masfuri2), Liya Arista3)1,2,3 Fakultas Ilmu Keperawatan Univers...
Iranian stroke model-how to involve health policymakers
Iranian stroke model-how to involve health policymakers
Stroke in Iran, with more than 83 million population, is a leading cause of disability and mortality in adults. Stroke has higher incidence in Iran comparing the global situation a...
HIPERTENSI, USIA, JENIS KELAMIN DAN KEJADIAN STROKE DI RUANG RAWAT INAP STROKE RSUD dr. M. YUNUS BENGKULU
HIPERTENSI, USIA, JENIS KELAMIN DAN KEJADIAN STROKE DI RUANG RAWAT INAP STROKE RSUD dr. M. YUNUS BENGKULU
Hypertension, Age, Sex, and Stroke Incidence In Stroke Installation Room RSUD dr. M. Yunus BengkuluABSTRAKStroke adalah gejala-gejala defisit fungsi susunan saraf yang diakibatka...
INFORMASI CITRA MRCP CORONAL T2 SSFSE DENGAN TEKNIK BREATH-HOLD DAN RESPIRATORY TRIGGERING PADA KASUS CHOLELITHIASIS
INFORMASI CITRA MRCP CORONAL T2 SSFSE DENGAN TEKNIK BREATH-HOLD DAN RESPIRATORY TRIGGERING PADA KASUS CHOLELITHIASIS
Penggunaan teknik breath-hold dan respiratory triggering dapat mencegah pergerakan pernapasan yang menyebabkan artefak pada hasil citra pemeriksaan Magnetic Resonance Cholangio Pan...
PENGGUNAAN CITRA HIMPUNAN JULIA SEBAGAI CITRA SAMPUL UNTUK MENYEMBUNYIKAN CITRA RAHASIA
PENGGUNAAN CITRA HIMPUNAN JULIA SEBAGAI CITRA SAMPUL UNTUK MENYEMBUNYIKAN CITRA RAHASIA
Steganografi dengan metode fraktal (fractal steganography) adalah teknik menyembunyikan informasi atau pesan, yang dapat berupa citra rahasia, dalam suatu citra sampul (cover image...

