Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Blind Source Separation of Transformer Acoustic Signal Based on Sparse Component Analysis

View through CrossRef
In the acoustics-based power transformer fault diagnosis, a transformer acoustic signal collected by an acoustic sensor is generally mixed with a large number of interference signals. In order to separate transformer acoustic signals from mixed acoustic signals obtained by a small number of sensors, a blind source separation (BSS) method of transformer acoustic signal based on sparse component analysis (SCA) is proposed in this paper. Firstly, the mixed acoustic signals are transformed from time domain to time–frequency (TF) domain, and single source points (SSPs) in the TF plane are extracted by identifying the phase angle differences of the TF points. Then, the mixing matrix is estimated by clustering SSPs with a density clustering algorithm. Finally, the transformer acoustic signal is separated from the mixed acoustic signals based on the compressed sensing theory. The results of the simulation and experiment show that the proposed method can separate the transformer acoustic signal from the mixed acoustic signals in the case of underdetermination. Compared with the existing denoising methods of the transformer acoustic signal, the denoising results of the proposed method have less error and distortion. It will provide important data support for the acoustics-based power transformer fault diagnosis.
Title: Blind Source Separation of Transformer Acoustic Signal Based on Sparse Component Analysis
Description:
In the acoustics-based power transformer fault diagnosis, a transformer acoustic signal collected by an acoustic sensor is generally mixed with a large number of interference signals.
In order to separate transformer acoustic signals from mixed acoustic signals obtained by a small number of sensors, a blind source separation (BSS) method of transformer acoustic signal based on sparse component analysis (SCA) is proposed in this paper.
Firstly, the mixed acoustic signals are transformed from time domain to time–frequency (TF) domain, and single source points (SSPs) in the TF plane are extracted by identifying the phase angle differences of the TF points.
Then, the mixing matrix is estimated by clustering SSPs with a density clustering algorithm.
Finally, the transformer acoustic signal is separated from the mixed acoustic signals based on the compressed sensing theory.
The results of the simulation and experiment show that the proposed method can separate the transformer acoustic signal from the mixed acoustic signals in the case of underdetermination.
Compared with the existing denoising methods of the transformer acoustic signal, the denoising results of the proposed method have less error and distortion.
It will provide important data support for the acoustics-based power transformer fault diagnosis.

Related Results

Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
High frequency modeling of power transformers under transients
High frequency modeling of power transformers under transients
This thesis presents the results related to high frequency modeling of power transformers. First, a 25kVA distribution transformer under lightning surges is tested in the laborator...
Subjective audiometric measures in individuals with repeated acoustic trauma in the combat zone
Subjective audiometric measures in individuals with repeated acoustic trauma in the combat zone
Intense sound exposure that exceeds the pain threshold of human auditory sensitivity, known as acoustic trauma, causes significant and extensive changes in the auditory system. Thr...
Research on Transformer Condition Recognition Based on Acoustic Signal and One-dimensional Convolutional Neural Networks
Research on Transformer Condition Recognition Based on Acoustic Signal and One-dimensional Convolutional Neural Networks
Abstract To solve the problem of transformer condition recognition, this paper propose a transformer condition recognition method based on acoustic signal and One-di...
Recognition of fish acoustic patterns at monitoring of freshwater ecosystems
Recognition of fish acoustic patterns at monitoring of freshwater ecosystems
The basic sources of contamination and obstruction of reservoirs are cleared not enough sewer water of industrial and communal enterprises, large stock-raising complexes, wastes of...
Acoustic Imaging based Covariance Matrix Fitting Algorithm for Transformer Fault Diagnosis
Acoustic Imaging based Covariance Matrix Fitting Algorithm for Transformer Fault Diagnosis
With the vigorous development of power system, fault diagnosis of power transformers is very important to ensure the normal operation of the power system. However, the traditional ...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
Research on Multi-source Sparse Optimization Method and Its Application On Polymorphic-oscillatory signal separation
Research on Multi-source Sparse Optimization Method and Its Application On Polymorphic-oscillatory signal separation
Abstract In general, during the whole life cycle operation of mechanical system, its corresponding condition signal often presents multi-component polymorphic-oscillatory c...

Back to Top