Blind Source Separation of Transformer Acoustic Signal Based on Sparse Component Analysis
View through CrossRef
In the acoustics-based power transformer fault diagnosis, a transformer acoustic signal collected by an acoustic sensor is generally mixed with a large number of interference signals. In order to separate transformer acoustic signals from mixed acoustic signals obtained by a small number of sensors, a blind source separation (BSS) method of transformer acoustic signal based on sparse component analysis (SCA) is proposed in this paper. Firstly, the mixed acoustic signals are transformed from time domain to time–frequency (TF) domain, and single source points (SSPs) in the TF plane are extracted by identifying the phase angle differences of the TF points. Then, the mixing matrix is estimated by clustering SSPs with a density clustering algorithm. Finally, the transformer acoustic signal is separated from the mixed acoustic signals based on the compressed sensing theory. The results of the simulation and experiment show that the proposed method can separate the transformer acoustic signal from the mixed acoustic signals in the case of underdetermination. Compared with the existing denoising methods of the transformer acoustic signal, the denoising results of the proposed method have less error and distortion. It will provide important data support for the acoustics-based power transformer fault diagnosis.
Title: Blind Source Separation of Transformer Acoustic Signal Based on Sparse Component Analysis
Description:
In the acoustics-based power transformer fault diagnosis, a transformer acoustic signal collected by an acoustic sensor is generally mixed with a large number of interference signals.
In order to separate transformer acoustic signals from mixed acoustic signals obtained by a small number of sensors, a blind source separation (BSS) method of transformer acoustic signal based on sparse component analysis (SCA) is proposed in this paper.
Firstly, the mixed acoustic signals are transformed from time domain to time–frequency (TF) domain, and single source points (SSPs) in the TF plane are extracted by identifying the phase angle differences of the TF points.
Then, the mixing matrix is estimated by clustering SSPs with a density clustering algorithm.
Finally, the transformer acoustic signal is separated from the mixed acoustic signals based on the compressed sensing theory.
The results of the simulation and experiment show that the proposed method can separate the transformer acoustic signal from the mixed acoustic signals in the case of underdetermination.
Compared with the existing denoising methods of the transformer acoustic signal, the denoising results of the proposed method have less error and distortion.
It will provide important data support for the acoustics-based power transformer fault diagnosis.
Related Results
Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
Study on acoustic source characteristics of gas pipeline leakage
Study on acoustic source characteristics of gas pipeline leakage
The characteristics of acoustic source of gas pipeline leakage determine the accuracy and adaptability of leak detection for gas pipelines based on acoustic method. In order to exp...
PLC Based Load Sharing of Transformers
PLC Based Load Sharing of Transformers
The transformer is very expensive and bulky power system equipment. It runs and feed the load for 24 hours a day. Sometimes the load on the transformer unexpectedly rises above its...
Research on Acoustic Emission Source Localization Technology Based on AI Deep Learning
Research on Acoustic Emission Source Localization Technology Based on AI Deep Learning
Acoustic emission source localization is the basic function of the application of acoustic emission technology. For complex structures, mathematical analysis positioning algorithms...
Simulation modeling study on short circuit ability of distribution transformer
Simulation modeling study on short circuit ability of distribution transformer
Abstract
Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical dama...
Low Latency Convolutive Blind Source Separation
Low Latency Convolutive Blind Source Separation
<p>In most real-time systems, particularly for applications involving system identification, latency is a critical issue. These applications include, but are not limited to, ...