Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Analysis of Transformer Using Flyback Converter Circuit

View through CrossRef
This paper discusses two types of transformers 3 A and 5 A with the addition of a flyback converter circuit. The transformer 3 A is only able to lower the DC output voltage and cannot produce an AC output voltage. So that the addition of a flyback converter circuit is proposed to change the AC output voltage and increase the voltage based on the desired load. The results of the 3 A transformer test obtained an increased output voltage from 12.21 Vdc to 18.04 Vdc with a constant time period of 1 minute. While testing the 5 A transformer shows that the increase in output voltage is obtained by adding a flyback converter circuit. The result of the output voltage with the addition of a flyback converter circuit reaches 221 Vac to 252.2 Vac. The increase in output voltage is directly proportional to a constant time period of one minute.
Title: Analysis of Transformer Using Flyback Converter Circuit
Description:
This paper discusses two types of transformers 3 A and 5 A with the addition of a flyback converter circuit.
The transformer 3 A is only able to lower the DC output voltage and cannot produce an AC output voltage.
So that the addition of a flyback converter circuit is proposed to change the AC output voltage and increase the voltage based on the desired load.
The results of the 3 A transformer test obtained an increased output voltage from 12.
21 Vdc to 18.
04 Vdc with a constant time period of 1 minute.
While testing the 5 A transformer shows that the increase in output voltage is obtained by adding a flyback converter circuit.
The result of the output voltage with the addition of a flyback converter circuit reaches 221 Vac to 252.
2 Vac.
The increase in output voltage is directly proportional to a constant time period of one minute.

Related Results

Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
Simulation modeling study on short circuit ability of distribution transformer
Simulation modeling study on short circuit ability of distribution transformer
Abstract Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical dama...
Analysis and Simulation of Boost-Flyback Converter for Renewable Energy Integration
Analysis and Simulation of Boost-Flyback Converter for Renewable Energy Integration
Analysis and Simulation of Boost-Flyback Converter for Renewable Energy Integration is mainly focusing on boosting and decreasing the voltages coming from the renewable energy sour...
Katalis Plat Kuningan Berbentuk Sarang Lebah untuk Mengurangi Emisi Kendaraan Bermotor
Katalis Plat Kuningan Berbentuk Sarang Lebah untuk Mengurangi Emisi Kendaraan Bermotor
Meningkatnya jumlah kendaraan bermotor berdampak langsung terhadap pencemaran udara akibat gas buang. Pencemaran udara di perkotaan didominasi oleh emisi kendaraan bermotor, disert...
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Buck-boost Converter is the device with the function to convert DC Voltage input to the setpoint DC Voltage output. Buck-boost converter can be used for regulating unstable voltage...
Design of Buck Converter Based on Maximum Power Point Tracking for Photovoltaic Applications
Design of Buck Converter Based on Maximum Power Point Tracking for Photovoltaic Applications
e MPPT converter ensures that the PV system operates at the maximum power point, which is the point where the solar panels can generate the most power. This is done by adjusting th...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...

Back to Top