Javascript must be enabled to continue!
Clinical Outcomes After Cataract Surgery With a New Transitional Toric Intraocular Lens
View through CrossRef
PURPOSE:
To evaluate the visual outcomes of patients who underwent cataract surgery with implantation of a transitional toric monofocal intraocular lens (IOL) (Precizon Toric IOL, model 565; Ophtec BV, Groningen, The Netherlands).
METHODS:
In this prospective case series, 51 eyes of 39 patients with cataract and regular keratometric astigmatism between 1.00 and 4.50 diopters (D) that had phacoemulsification with implantation of a Precizon Toric IOL were included. Over a 4-month follow-up period, the main outcome measures were uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively), spherical equivalent (SE) refraction, astigmatism outcomes evaluated according to the Alpins method, the IOL's rotational stability, and higher order aberrations.
RESULTS:
At the 4-month follow-up visit, mean UDVA was 0.06 ± 0.1 logMAR (range: 0.4 to −0.18 logMAR) (
P
< .001) and mean CDVA was −0.00 ± 0.07 logMAR (range: 0.15 to −0.18 logMAR) (
P
< .001). UDVA was 0.3 logMAR or better in 50 (98%) eyes and 0.1 logMAR or better in 42 (82%) eyes. Mean SE refraction was −0.19 ± 0.38 D (range: −1.13 to +0.50 D), with 44 (86%) eyes within ±0.50 D of the attempted correction. Mean target induced astigmatism was 1.96 ± 0.94 D (range: 0.70 to 4.50 D) and mean surgically induced astigmatism was 1.85 ± 1.01 D (range: 0.07 to 4.64 D). Mean correction index was 0.87 (range: 0.07 to 2.29 D). Mean toric IOL axis rotation was 1.98° ± 1.78° (range: 0° to 7°). Ocular aberrometry was within normal values.
CONCLUSIONS:
The implantation of the Precizon Toric IOL in patients with cataract and corneal astigmatism provided excellent visual outcomes, predictability of refractive results, rotational stability, and good optical performance.
[
J Refract Surg.
2016;32(7):452–458.]
Title: Clinical Outcomes After Cataract Surgery With a New Transitional Toric Intraocular Lens
Description:
PURPOSE:
To evaluate the visual outcomes of patients who underwent cataract surgery with implantation of a transitional toric monofocal intraocular lens (IOL) (Precizon Toric IOL, model 565; Ophtec BV, Groningen, The Netherlands).
METHODS:
In this prospective case series, 51 eyes of 39 patients with cataract and regular keratometric astigmatism between 1.
00 and 4.
50 diopters (D) that had phacoemulsification with implantation of a Precizon Toric IOL were included.
Over a 4-month follow-up period, the main outcome measures were uncorrected and corrected distance visual acuities (UDVA and CDVA, respectively), spherical equivalent (SE) refraction, astigmatism outcomes evaluated according to the Alpins method, the IOL's rotational stability, and higher order aberrations.
RESULTS:
At the 4-month follow-up visit, mean UDVA was 0.
06 ± 0.
1 logMAR (range: 0.
4 to −0.
18 logMAR) (
P
< .
001) and mean CDVA was −0.
00 ± 0.
07 logMAR (range: 0.
15 to −0.
18 logMAR) (
P
< .
001).
UDVA was 0.
3 logMAR or better in 50 (98%) eyes and 0.
1 logMAR or better in 42 (82%) eyes.
Mean SE refraction was −0.
19 ± 0.
38 D (range: −1.
13 to +0.
50 D), with 44 (86%) eyes within ±0.
50 D of the attempted correction.
Mean target induced astigmatism was 1.
96 ± 0.
94 D (range: 0.
70 to 4.
50 D) and mean surgically induced astigmatism was 1.
85 ± 1.
01 D (range: 0.
07 to 4.
64 D).
Mean correction index was 0.
87 (range: 0.
07 to 2.
29 D).
Mean toric IOL axis rotation was 1.
98° ± 1.
78° (range: 0° to 7°).
Ocular aberrometry was within normal values.
CONCLUSIONS:
The implantation of the Precizon Toric IOL in patients with cataract and corneal astigmatism provided excellent visual outcomes, predictability of refractive results, rotational stability, and good optical performance.
[
J Refract Surg.
2016;32(7):452–458.
].
Related Results
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Urrets-Zavalia syndrome following implantable collamer lens (ICL) implantation: a case report and review of the literature
Abstract
Background
Urrets-Zavalia syndrome is a condition that arises after eye surgery, often linked to increased intraocular pressure followin...
Comparison of Toric Intraocular Lens Calculations Between the IOLMaster 700 and Pentacam AXL
Comparison of Toric Intraocular Lens Calculations Between the IOLMaster 700 and Pentacam AXL
Purpose: To compare toric IOL (Intra Ocular Lenses) suggestions for power, toric, and IOL alignment between the IOLMaster 700 and Pentacam AXL (Axial Length).
Methods: This single-...
The impact of cataract surgery on tear film physiology: signs and symptoms, progression and treatment
The impact of cataract surgery on tear film physiology: signs and symptoms, progression and treatment
PurposeThis study aimed to revise data published in the literature on the effects of cataract surgery on tear film characteristics, in relation to personal clinical surgical experi...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract
Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 patien...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract
Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism.
Methods: 31 eyes of 31 patie...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract
Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 patien...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity
Abstract
Background: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 pat...
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Toric Intraocular Lens Implantation in Cataract Patients with Corneal Opacity.
Abstract
Purpose: To evaluate the effect of toric intraocular lens implantation in cataract patient with corneal opacity and high astigmatism. Methods: 31 eyes of 31 patien...

