Uji Performa Trafo E-I dengan Variasi Rapat Fluks pada Sumber Tegangan Non-Sinusoidal

View through CrossRef
In the industrial field, transformers are used as a step-up voltage and are used as a step-down level. In a loaded transformer, the power that comes out of the transformer (transformer output power) is not always 100% because there are losses when channeling to the load. Both losses caused by current flowing in the copper wire, losses caused by alternating flux in the iron core, and losses caused by Eddy current in the iron core which result in the outgoing power (output power) from the transformer to the load is not the same as the incoming power (input power) to the transformer. This is known as the efficiency of the transformer. From these problems, the solution offered is to design and implement a transformer using an EI-shaped iron core which is arranged alternately which aims to prevent the occurrence of Eddy Current what happens in the coresolid by applying to the inverter. From the test results of the transformer, it can be concluded that the difference in flux density in the transformer when it is loaded will affect efficiency. The smaller the flux density of the transformer, the better the efficiency, while the greater the flux density of the transformer, the lower the efficiency.
Title: Uji Performa Trafo E-I dengan Variasi Rapat Fluks pada Sumber Tegangan Non-Sinusoidal
Description:
In the industrial field, transformers are used as a step-up voltage and are used as a step-down level.
In a loaded transformer, the power that comes out of the transformer (transformer output power) is not always 100% because there are losses when channeling to the load.
Both losses caused by current flowing in the copper wire, losses caused by alternating flux in the iron core, and losses caused by Eddy current in the iron core which result in the outgoing power (output power) from the transformer to the load is not the same as the incoming power (input power) to the transformer.
This is known as the efficiency of the transformer.
From these problems, the solution offered is to design and implement a transformer using an EI-shaped iron core which is arranged alternately which aims to prevent the occurrence of Eddy Current what happens in the coresolid by applying to the inverter.
From the test results of the transformer, it can be concluded that the difference in flux density in the transformer when it is loaded will affect efficiency.
The smaller the flux density of the transformer, the better the efficiency, while the greater the flux density of the transformer, the lower the efficiency.

Related Results

Analisa Pengaruh Tegangan Harmonik Terhadap Regulasi Tegangan Eksitasi Generator Satu Fasa
Analisa Pengaruh Tegangan Harmonik Terhadap Regulasi Tegangan Eksitasi Generator Satu Fasa
Esensinya setiap generator listrik satu fasa maupun tiga fasa telah dilengkapi dengan sistem eksitasi. Sistem eksitasi generator ada tiga, yaitu sistem eksitasi statis, dinamis, da...
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature  Review Anna Tri Wahyuni1), Masfuri2),  Liya Arista3)1,2,3 Fakultas Ilmu Keperawatan Univers...
Analisis Rugi Tegangan Jaringan Distribusi 20 KV Pada PT. PLN (Persero) Cabang Merauke
Analisis Rugi Tegangan Jaringan Distribusi 20 KV Pada PT. PLN (Persero) Cabang Merauke
Sistem Distribusi merupakan salah satu bagian penting dalam penyaluran energi listrik. Dalam penyalurannya, energi listrik yang disalurkan tidak seluruhnya diterima oleh konsumen. ...
Analisis Penanganan Gangguan Kedip Tegangan Pada Penyulang Sampoerna 1 Tegangan 20 kV
Analisis Penanganan Gangguan Kedip Tegangan Pada Penyulang Sampoerna 1 Tegangan 20 kV
Berdasarkan kejadian pada tanggal 17 Desember 2017, terjadi gangguan kedip tegangan yang berhasil direkam dengan PQA (Power Quality Analyzer) milik PT. HM Sampoerna dengan nilai pe...
SISTEM PROTEKSI TEGANGAN UNTUK SMART MICRO INVERTER PADA PLTS ON GRID SKALA KECIL
SISTEM PROTEKSI TEGANGAN UNTUK SMART MICRO INVERTER PADA PLTS ON GRID SKALA KECIL
Inverter pada pembangkit listrik tenaga surya (PLTS) on grid kapasitas kecil adalah smart micro inverter (SMI). SMI mensinkronkan daya yang dihasilkan oleh PLTS ke grid apabila sya...
KECEMASAN SAAT PANDEMI COVID 19: LITERATUR REVIEW Hardiyati, Efri Widianti, Taty Hernawaty Departemen Keperawatan Jiwa Poltekkes Kemenkes Mamuju Sulbar, Universitas Pad...

Back to Top