Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Design and Evaluation of a Modified Underwater Cycle Ergometer

View through CrossRef
An underwater cycle ergometer was designed consisting of an aluminum cycle frame in water connected with a 1:1 gear ratio to a mechanically braked standard cycle ergometer supported above the water. Three progressive maximal exercise tests were performed (n = 10): (a) the underwater ergometer in water (UEW), (b) underwater ergometer in air (UEA), and (c) a standard cycle ergometer in air (SEA). At submaximal power outputs, oxygen consumption [Formula: see text] and heart rate (HR) were generally lower in the SEA condition (p <.05), indicating that exercise in the upright position was more efficient. Exercise in water (UEW) resulted in lower total exercise duration, maximal HR, and maximal Tes than in air conditions. The upright position (SEA) resulted in greater total exercise duration and maximal power output than the semirecumbent positions. Because of positional differences between the standard and underwater ergometers, air-water comparisons should be made by using the underwater ergometer in water and on land. Key words: core temperature, esophageal temperature, skin temperature, exercise, resistance, work, power output, heat balance, heat loss, heat production, thermoregulation
Title: Design and Evaluation of a Modified Underwater Cycle Ergometer
Description:
An underwater cycle ergometer was designed consisting of an aluminum cycle frame in water connected with a 1:1 gear ratio to a mechanically braked standard cycle ergometer supported above the water.
Three progressive maximal exercise tests were performed (n = 10): (a) the underwater ergometer in water (UEW), (b) underwater ergometer in air (UEA), and (c) a standard cycle ergometer in air (SEA).
At submaximal power outputs, oxygen consumption [Formula: see text] and heart rate (HR) were generally lower in the SEA condition (p <.
05), indicating that exercise in the upright position was more efficient.
Exercise in water (UEW) resulted in lower total exercise duration, maximal HR, and maximal Tes than in air conditions.
The upright position (SEA) resulted in greater total exercise duration and maximal power output than the semirecumbent positions.
Because of positional differences between the standard and underwater ergometers, air-water comparisons should be made by using the underwater ergometer in water and on land.
Key words: core temperature, esophageal temperature, skin temperature, exercise, resistance, work, power output, heat balance, heat loss, heat production, thermoregulation.

Related Results

A new conceptual design for subsea charging station
A new conceptual design for subsea charging station
With deepening ocean development , a larger scale Internet of Underwater Things (IoUT) is being realized[1].More and more underwater equipment is being deployed, various ocean moni...
Peningkatan Prestasi Belajar Materi Bilangan Berpangkat Melalui Model Discovery Learning
Peningkatan Prestasi Belajar Materi Bilangan Berpangkat Melalui Model Discovery Learning
This research is motivated by the unoptimally the mastery of the material is still not optimal exponential number among learners and implementation Discovery learning in mathematic...
Emerging underwater survey technologies: A review and future outlook
Emerging underwater survey technologies: A review and future outlook
Emerging underwater survey technologies are revolutionizing the way we explore and understand the underwater world. This review examines the latest advancements in underwater surve...
The Synthesis of Unpaired Underwater Images for Monocular Underwater Depth Prediction
The Synthesis of Unpaired Underwater Images for Monocular Underwater Depth Prediction
Underwater depth prediction plays an important role in underwater vision research. Because of the complex underwater environment, it is extremely difficult and expensive to obtain ...
Edge Enhanced CrackNet for Underwater Crack Detection of Concrete Dams
Edge Enhanced CrackNet for Underwater Crack Detection of Concrete Dams
Underwater crack detection in dam structures is of significant engineering importance and scientific value for ensuring the structural safety, assessing operational conditions, and...
Optimizing Underwater Vision: A Rigorous Investigation into CNN's Deep Image Enhancement for Subaquatic Scenes
Optimizing Underwater Vision: A Rigorous Investigation into CNN's Deep Image Enhancement for Subaquatic Scenes
In this paper, Convolutional Neural Networks were used to enhance the visual fidelity of underwater images. The UWCNN is introduced in this article, which utilizes underwater scene...
Underwater Pile Driving Test Offshore Louisiana
Underwater Pile Driving Test Offshore Louisiana
ABSTRACT This report presents results of an underwater pile driving test conducted at South Marsh Island Block 130, offshore Louisiana. A 24inch diameter tubular ...
Design
Design
Conventional definitions of design rarely capture its reach into our everyday lives. The Design Council, for example, estimates that more than 2.5 million people use design-related...

Back to Top