Abstract 17285: Impact of Baseline Yellow Plaque Assessed by Coronary Angioscopy on 11-month Vascular Response After Stent Implantation

View through CrossRef
Background: In-stent yellow plaque (YP) evaluated by coronary angioscopy (CAS) 1 year after stent implantation is associated with the future adverse cardiac event. However, the impact of baseline YP on vascular response has not been fully investigated. Methods: This was a sub-analysis of the Collaboraiton-1 study (multicenter, retrospective, observational study). A total of 88 lesions from 80 patients with chronic coronary syndrome who underwent percutaneous coronary intervention with polymer-free biolimus A9-coated stent or durable-polymer everolimus-eluting stent implantation were analyzed. Optical coherence tomography (OCT) and CAS were serially performed immediately and 11 months after stent implantation. YP was defined as the stented segment with yellow or intensive yellow color assessed by CAS. Neoatherosclerosis was defined as a lipid or calcified neointima assessed by OCT. Neointimal coverage (NIC) over the stent was classified into 4 grades by CAS: grade 0, stent struts fully visible; grade 1, stent struts bulging into the lumen, although covered; grade 2, stent struts embedded in the neointima, but translucently visible; and grade 3, stent struts fully embedded and invisible. OCT and CAS findings at 11 months were compared between the lesions with baseline YP (YP group) and those without YP (Non-YP group). Results: Baseline YP was detected in 37 lesions (42%). OCT findings at 11 months showed that the incidence of neoatherosclerosis was significantly higher in YP than Non-YP groups (11% versus 0%, P=0.028) and mean neointimal thickness tended to be lower (104±43 μm versus 120±48 μm, P=0.098). CAS finding at 11 months demonstrated that dominant and minimum NIC grades were significantly lower (Figure) and maximum yellow color grade was significantly higher in YP than Non-YP groups. Conclusions: Baseline YP affected the incidence of neoatherosclerosis as well as poor neointimal coverage at 11 months after stent implantation.
Title: Abstract 17285: Impact of Baseline Yellow Plaque Assessed by Coronary Angioscopy on 11-month Vascular Response After Stent Implantation
Description:
Background: In-stent yellow plaque (YP) evaluated by coronary angioscopy (CAS) 1 year after stent implantation is associated with the future adverse cardiac event.
However, the impact of baseline YP on vascular response has not been fully investigated.
Methods: This was a sub-analysis of the Collaboraiton-1 study (multicenter, retrospective, observational study).
A total of 88 lesions from 80 patients with chronic coronary syndrome who underwent percutaneous coronary intervention with polymer-free biolimus A9-coated stent or durable-polymer everolimus-eluting stent implantation were analyzed.
Optical coherence tomography (OCT) and CAS were serially performed immediately and 11 months after stent implantation.
YP was defined as the stented segment with yellow or intensive yellow color assessed by CAS.
Neoatherosclerosis was defined as a lipid or calcified neointima assessed by OCT.
Neointimal coverage (NIC) over the stent was classified into 4 grades by CAS: grade 0, stent struts fully visible; grade 1, stent struts bulging into the lumen, although covered; grade 2, stent struts embedded in the neointima, but translucently visible; and grade 3, stent struts fully embedded and invisible.
OCT and CAS findings at 11 months were compared between the lesions with baseline YP (YP group) and those without YP (Non-YP group).
Results: Baseline YP was detected in 37 lesions (42%).
OCT findings at 11 months showed that the incidence of neoatherosclerosis was significantly higher in YP than Non-YP groups (11% versus 0%, P=0.
028) and mean neointimal thickness tended to be lower (104±43 μm versus 120±48 μm, P=0.
098).
CAS finding at 11 months demonstrated that dominant and minimum NIC grades were significantly lower (Figure) and maximum yellow color grade was significantly higher in YP than Non-YP groups.
Conclusions: Baseline YP affected the incidence of neoatherosclerosis as well as poor neointimal coverage at 11 months after stent implantation.

Related Results

Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract Introduction Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Novel functionalized and patterned surfaces for cardiovascular applications
Novel functionalized and patterned surfaces for cardiovascular applications
Nowadays, cardiovascular diseases are mainly treated by implantation of a metallic or polymeric mesh, called stent, which maintains the artery widely open. This technique shows ver...
Balloon/Stent Expansion Dynamics in Stenotic Arteries
Balloon/Stent Expansion Dynamics in Stenotic Arteries
Inflation balloons for stents are typically sized 1–2mm longer than endovascular stents, yet the effects of the degree of balloon overhang are unknown. In this study, a computation...
Clinical study of biodegradable polymer stent versus durable polymer stent in treating long coronary lesions
Clinical study of biodegradable polymer stent versus durable polymer stent in treating long coronary lesions
Objective This study compared the clinical efficacy and safety of homemade biodegradable polymer rapamycin-eluting stent (EXCEL TM) and durable polymer rapamycin-...

Back to Top