Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Behavior of Full-Scale One-Way Semi-Precast Concrete Slabs with Varying Sizes and Shear Connectors

View through CrossRef
This study investigates the structural performance of semi-precast concrete slabs (SPCSs), an innovative hybrid construction system that integrates factory-produced precast concrete units with a cast-in-place (CIP) concrete topping to create a composite structural element. This system offers notable advantages in terms of construction acceleration, improved quality control, and reduced labor requirements, as the precast unit serves as both a load-bearing component and a permanent formwork. To evaluate the structural behavior of the SPCSs, an experimental program was conducted on seven full-scale, one-way slab specimens with varying span lengths (4.75 m and 6.0 m), precast unit thicknesses (80 mm and 100 mm), and shear connector geometries (rectangular and triangular). A control slab without shear connectors was also tested to establish a baseline for comparison. The results demonstrated that the inclusion of shear connectors significantly enhanced structural performance. Specifically, the ultimate load capacity increased by 186.4%, and the cracking load increased by 220% compared to the control specimen. Rectangular connectors proved more effective than triangular ones in minimizing interface slip and enhancing ductility. The initial stiffness increased by 163.95%, while the energy dissipation capacity improved by 411.35%. Although variations in span length and topping thickness had relatively minor effects, the presence and geometry of shear connectors played a decisive role in ensuring effective composite action. All reinforced slabs exhibited flexural failure modes, indicating strong bonding and interaction between the precast and cast-in-place (CIP) concrete layers, whereas the control slab experienced premature failure due to interlayer debonding. Theoretical equations based on ACI 318-19 were used to estimate the nominal flexural capacities of the hybrid SPCS slabs, showing reliable agreement with the experimental results. These findings demonstrated the importance of shear connector design in maximizing the load-bearing capacity, ductility, and structural stiffness of SPCS systems under both service and extreme loading conditions.
Title: Behavior of Full-Scale One-Way Semi-Precast Concrete Slabs with Varying Sizes and Shear Connectors
Description:
This study investigates the structural performance of semi-precast concrete slabs (SPCSs), an innovative hybrid construction system that integrates factory-produced precast concrete units with a cast-in-place (CIP) concrete topping to create a composite structural element.
This system offers notable advantages in terms of construction acceleration, improved quality control, and reduced labor requirements, as the precast unit serves as both a load-bearing component and a permanent formwork.
To evaluate the structural behavior of the SPCSs, an experimental program was conducted on seven full-scale, one-way slab specimens with varying span lengths (4.
75 m and 6.
0 m), precast unit thicknesses (80 mm and 100 mm), and shear connector geometries (rectangular and triangular).
A control slab without shear connectors was also tested to establish a baseline for comparison.
The results demonstrated that the inclusion of shear connectors significantly enhanced structural performance.
Specifically, the ultimate load capacity increased by 186.
4%, and the cracking load increased by 220% compared to the control specimen.
Rectangular connectors proved more effective than triangular ones in minimizing interface slip and enhancing ductility.
The initial stiffness increased by 163.
95%, while the energy dissipation capacity improved by 411.
35%.
Although variations in span length and topping thickness had relatively minor effects, the presence and geometry of shear connectors played a decisive role in ensuring effective composite action.
All reinforced slabs exhibited flexural failure modes, indicating strong bonding and interaction between the precast and cast-in-place (CIP) concrete layers, whereas the control slab experienced premature failure due to interlayer debonding.
Theoretical equations based on ACI 318-19 were used to estimate the nominal flexural capacities of the hybrid SPCS slabs, showing reliable agreement with the experimental results.
These findings demonstrated the importance of shear connector design in maximizing the load-bearing capacity, ductility, and structural stiffness of SPCS systems under both service and extreme loading conditions.

Related Results

Investigation of shear‐flexural behavior of precast joints in prestressed reinforced concrete
Investigation of shear‐flexural behavior of precast joints in prestressed reinforced concrete
AbstractThe behavior of precast concrete structures at the limit states of ultimate bearing capacity depends on the shear and shear‐flexural behavior of the joints between precast ...
Preface: A SPECIAL ISSUE ON PROGRESS IN CIVIL ENGINEERING
Preface: A SPECIAL ISSUE ON PROGRESS IN CIVIL ENGINEERING
The Open Civil Engineering Journal, which is one of the most relevant international journals in civil engineering area, wishes to promote the latest researches in engineering s...
Experimental and theoretical study on shear performance of T-shaped and bulb flat shear connectors in composite structures
Experimental and theoretical study on shear performance of T-shaped and bulb flat shear connectors in composite structures
This study investigates the mechanical performance and theoretical design methods of T-shaped and bulb flat shear connectors in large-scale steel-concrete composite structures. The...
EXPERIMENTAL INVESTIGATION ON THE SHEAR RESISTANCE OF I-SHAPED PERFORATED CONNECTORS IN COMPOSITE BEAMS
EXPERIMENTAL INVESTIGATION ON THE SHEAR RESISTANCE OF I-SHAPED PERFORATED CONNECTORS IN COMPOSITE BEAMS
Introduction: Steel-concrete composite girders have been widely used in bridges, with the stability of the interface being crucial. Shear connectors and reinforced concrete slabs p...
Behaviour of reinforced concrete slabs strengthened by concrete overlays
Behaviour of reinforced concrete slabs strengthened by concrete overlays
This paper discusses the influence of three factors, the distribution of shear connectors, the concrete compressive strength, addition of new concrete thickness on the behavior of ...
CONSTRUCTION METHOD OF ABILA PRECAST CONCRETE FOR HOUSING
CONSTRUCTION METHOD OF ABILA PRECAST CONCRETE FOR HOUSING
The purpose of this research is to arrange the stages of implementation of the ABILA precast concrete construction method to be applied to housing construction so that it can be us...
CONSTRUCTION METHOD OF ABILA PRECAST CONCRETE FOR HOUSING
CONSTRUCTION METHOD OF ABILA PRECAST CONCRETE FOR HOUSING
The purpose of this research is to arrange the stages of implementation of the ABILA precast concrete construction method to be applied to housing construction so that it can be us...
Impact Loading of Circular Slabs Using Curvilinear Shear Reinforcement Under Different Support Conditions
Impact Loading of Circular Slabs Using Curvilinear Shear Reinforcement Under Different Support Conditions
Abstract The impact resistance and punching behavior of circular reinforced concrete slabs are critical for structures subjected to localized dynamic loading. This ...

Back to Top