Study on insulation performance of EPR cable terminal containing metal particles
View through CrossRef
Abstract
The 35kV EPR cable terminal is widely used in the distribution network. During the production process, metal particles are easily introduced due to environmental and technological reasons, resulting in frequent breakdown of the terminal breakdown accident. In order to study the influence of metal particles on the insulation performance of EPR cable terminals, a model of metal particles defect in cable terminals on the extension line of the main insulation and the control tube is built. The electric field distribution of cable terminals under power frequency voltage is calculated by COMSOL simulation software. At the same time, a sample of cable terminals containing metal particles is made, and local discharge is used. The partial discharge information of the cable terminal sample is tested by the electric test platform. The results show that the introduction of metal particles will increase the electric field distortion inside the cable terminal, strengthen the discharge activity of the cable terminal, and increase the discharge amount significantly, which seriously affects the insulation performance of the EPDM cable terminal.
Title: Study on insulation performance of EPR cable terminal containing metal particles
Description:
Abstract
The 35kV EPR cable terminal is widely used in the distribution network.
During the production process, metal particles are easily introduced due to environmental and technological reasons, resulting in frequent breakdown of the terminal breakdown accident.
In order to study the influence of metal particles on the insulation performance of EPR cable terminals, a model of metal particles defect in cable terminals on the extension line of the main insulation and the control tube is built.
The electric field distribution of cable terminals under power frequency voltage is calculated by COMSOL simulation software.
At the same time, a sample of cable terminals containing metal particles is made, and local discharge is used.
The partial discharge information of the cable terminal sample is tested by the electric test platform.
The results show that the introduction of metal particles will increase the electric field distortion inside the cable terminal, strengthen the discharge activity of the cable terminal, and increase the discharge amount significantly, which seriously affects the insulation performance of the EPDM cable terminal.
Related Results
The retinal pigment epithelium during the progression of geographic atrophy : clinical and histological correlation
The retinal pigment epithelium during the progression of geographic atrophy : clinical and histological correlation
Physiopathologie de la DMLA sèche : compréhension de la mécanique cellulaire à l'origine de la progression de l'atrophie
Le vieillissement de la population entraîne...
Deep Learning Training Model Construction and Optimization of Cable Size Features in 3D Point Cloud Data
Deep Learning Training Model Construction and Optimization of Cable Size Features in 3D Point Cloud Data
Cables are widely used in power transmission, and the measurement of key dimensions of cables is an indispensable part of the cable preparation process to help ensure their quality...
Kajian Kondisi Fisik Terminal Leuwipanjang Berdasarkan Persepsi Penumpang
Kajian Kondisi Fisik Terminal Leuwipanjang Berdasarkan Persepsi Penumpang
Leuwipanjang terminal is a passenger terminal serving AKDP and AKAP. UPTD Terminal is required to provide convenient facilities for passengers during activities within the Terminal...
Optimalisasi Pemanfaatan Dan Pengelolaan Terminal Angkutan Umum Sawerigading Kota Sengkang Kabupaten Wajo
Optimalisasi Pemanfaatan Dan Pengelolaan Terminal Angkutan Umum Sawerigading Kota Sengkang Kabupaten Wajo
Tujuan dari penelitian ini yaitu Menganalisis faktor-faktor teridentifikasi yang mempengaruhi ketidakoptimalan pemanfaatan dan pengelolaan terminal angkutan umum Sawerigading Kota ...
Evaluasi Efektivitas Terminal Penumpang Cileunyi
Evaluasi Efektivitas Terminal Penumpang Cileunyi
Abstract. The transportation system is affected by dynamic regional developments, one of which is the Cileunyi Terminal as a transportation node in Bandung Regency, which has probl...
Metode Analytical Hierarchy Process dalam Menentukan Faktor-Faktor yang Mempengaruhi Efektivitas Penggunaan Terminal Bandar Laksamana Indragiri
Metode Analytical Hierarchy Process dalam Menentukan Faktor-Faktor yang Mempengaruhi Efektivitas Penggunaan Terminal Bandar Laksamana Indragiri
[ID] Keberadaan Terminal Bandar Laksamana Indragiri belum berfungsi secara efektif yang disebabkan oleh rendahnya pemanfaatan terminal oleh masyarakat. Aktivitas operasional yang...
Analysis of Radicals byEPR
Analysis of Radicals byEPR
AbstractThis article explains why electron paramagnetic resonance (EPR) spectroscopy is one of the most versatile and useful techniques for investigating free radicals. Easy to use...
KARAKTER FASAD BANGUNAN TERMINAL PENUMPANG BANDAR UDARA INTERNASIONAL SOEKARNO HATTA
KARAKTER FASAD BANGUNAN TERMINAL PENUMPANG BANDAR UDARA INTERNASIONAL SOEKARNO HATTA
ABSTRAK. Bandar Udara Internasional Soekarno-Hatta merupakan pintu gerbang ke berbagai negara/daerah maka bentuk bangunan terminal penumpang dapat memberikan ciri khas atau iden...