Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Analisis dan Simulasi Efisiensi Kinerja Sepic Konverter Berbasis Kontroler Konvensional

View through CrossRef
The technology of components and electronic hardware has evolved to be able to produce a DC/DC current system for power, which is achieved by converting the DC power to higher or lower voltage. This DC voltage variable is commonly called the DC-DC Converter. This final task aims to find out the performance of the DC-DC Sepic Converter series design. The simulated testing of the system using SIMULINK/MATLAB software is subsequently obtained from the data analysis of the theoretical output voltage data and the monitoring of measurements that can be analyzed to determine the error level as well as the level of efficiency of the design of the sepic converter. The test was conducted by setting a constant input voltage of 12 V, a frequency of 50 kHz, with a duty cycle variation of 5% to 65% and a given load of 20 Ω. The result of the design of the Sepic Converter at the time of open loop mode with the value of duty Cycle of 5% produces a minimum voltage that is 0,38 V. Subsequently, when given the duty cicle value of 65%, the maximum voltage is 21,22 V error with the highest error rate of 1 V obtained at the 13th data trial. The average error value is 0,642 V and the standard deviation value is 0,453 V, the greatest efficiency point is 78,50% at the moment of the cycle duty value of 65. While the results of the testing of the Set of Sepic Konverters at the close loop mode, the input tension is given constantly 12 V. The configuration for the parameter value of PI is also constant, namely at the set point of 22,22 V, it is 21,97 V with an error difference 0,25 V.
Title: Analisis dan Simulasi Efisiensi Kinerja Sepic Konverter Berbasis Kontroler Konvensional
Description:
The technology of components and electronic hardware has evolved to be able to produce a DC/DC current system for power, which is achieved by converting the DC power to higher or lower voltage.
This DC voltage variable is commonly called the DC-DC Converter.
This final task aims to find out the performance of the DC-DC Sepic Converter series design.
The simulated testing of the system using SIMULINK/MATLAB software is subsequently obtained from the data analysis of the theoretical output voltage data and the monitoring of measurements that can be analyzed to determine the error level as well as the level of efficiency of the design of the sepic converter.
The test was conducted by setting a constant input voltage of 12 V, a frequency of 50 kHz, with a duty cycle variation of 5% to 65% and a given load of 20 Ω.
The result of the design of the Sepic Converter at the time of open loop mode with the value of duty Cycle of 5% produces a minimum voltage that is 0,38 V.
Subsequently, when given the duty cicle value of 65%, the maximum voltage is 21,22 V error with the highest error rate of 1 V obtained at the 13th data trial.
The average error value is 0,642 V and the standard deviation value is 0,453 V, the greatest efficiency point is 78,50% at the moment of the cycle duty value of 65.
While the results of the testing of the Set of Sepic Konverters at the close loop mode, the input tension is given constantly 12 V.
The configuration for the parameter value of PI is also constant, namely at the set point of 22,22 V, it is 21,97 V with an error difference 0,25 V.

Related Results

Analisis kondisi tunak dan simulasi konverter DC-DC buck-boost
Analisis kondisi tunak dan simulasi konverter DC-DC buck-boost
Energi baru terbarukan mengalami perkembangan yang sangat pesat, terutama pada teknologi yang ada pada konverter. Dengan mengalisis operasi kerja dari suatu konverter tersebut, mak...
PERANCANGAN KONVERTER ARUS SEARAH TIPE SYNCHRONOUS BUCK BERBASIS IC TL494
PERANCANGAN KONVERTER ARUS SEARAH TIPE SYNCHRONOUS BUCK BERBASIS IC TL494
Elektronika daya merupakan salah satu bidang penting dalam ketenagalistrikan. Ciri khas pada elektronika daya adalah penggunaan Switched Mode Power Supply (SMPS). Pada konverter ar...
An Extended Sepic DC-DC Converter for Micro-Grid Based Photovoltaic (Pv) Applications.
An Extended Sepic DC-DC Converter for Micro-Grid Based Photovoltaic (Pv) Applications.
Abstract Background The demands for clean energy is growing rapidly and the fossil fuel we use in our everyday live is ushered in CO2 and other greenhouse effects, resulti...
TEKNIK SWITCHING UNTUK KONVERSI ENERGI DC EFISIENSI TINGGI
TEKNIK SWITCHING UNTUK KONVERSI ENERGI DC EFISIENSI TINGGI
Konversi energi listrik DC dengan menggunakan konverter linier memiliki kelemahan utama yaitu hanya dapat mengkonversikan dari tegangan tinggi ke tegang...
DAMPAK TEKNOLOGI TERHADAP PROSES BELAJAR MENGAJAR
DAMPAK TEKNOLOGI TERHADAP PROSES BELAJAR MENGAJAR
DAFTAR PUSTAKAAditama, M. H. R., & Selfiardy, S. (2022). Kehidupan Mahasiswa Kuliah Sambil Bekerja di Masa Pandemi Covid-19. Kidspedia: Jurnal Pendidikan Anak Usia Dini, 3(...

Back to Top