Javascript must be enabled to continue!
Simultaneous calibration and inversion algorithm for multiconfiguration electromagnetic induction data acquired at multiple elevations
View through CrossRef
Electromagnetic induction (EMI) is a contactless and fast geophysical measurement technique. Frequency-domain EMI systems are available as portable rigid booms with fixed separations up to approximately 4 m between the transmitter and the receivers. These EMI systems are often used for high-resolution characterization of the upper subsurface meters (up to depths of approximately 1.5 times the maximum coil separation). The availability of multiconfiguration EMI systems, which measure multiple apparent electrical conductivity ([Formula: see text]) values of different but overlapping soil volumes, enables EMI data inversions to estimate electrical conductivity ([Formula: see text]) changes with depth. However, most EMI systems currently do not provide absolute [Formula: see text] values, but erroneous shifts occur due to calibration problems, which hinder a reliable inversion of the data. Instead of using physical soil data or additional methods to calibrate the EMI data, we have used an efficient and accurate simultaneous calibration and inversion approach to avoid a possible bias of other methods while reducing the acquisition time for the calibration. By measuring at multiple elevations above the ground surface using a multiconfiguration EMI system, we simultaneously obtain multiplicative and additive calibration factors for each coil configuration plus an inverted layered subsurface electrical conductivity model at the measuring location. Using synthetic data, we verify our approach. Experimental data from five different calibration positions along a transect line showed similar calibration results as the data obtained by more elaborate vertical electrical sounding reference measurements. The synthetic and experimental results demonstrate that the multielevation calibration and inversion approach is a promising tool for quantitative electrical conductivity analyses.
Society of Exploration Geophysicists
Title: Simultaneous calibration and inversion algorithm for multiconfiguration electromagnetic induction data acquired at multiple elevations
Description:
Electromagnetic induction (EMI) is a contactless and fast geophysical measurement technique.
Frequency-domain EMI systems are available as portable rigid booms with fixed separations up to approximately 4 m between the transmitter and the receivers.
These EMI systems are often used for high-resolution characterization of the upper subsurface meters (up to depths of approximately 1.
5 times the maximum coil separation).
The availability of multiconfiguration EMI systems, which measure multiple apparent electrical conductivity ([Formula: see text]) values of different but overlapping soil volumes, enables EMI data inversions to estimate electrical conductivity ([Formula: see text]) changes with depth.
However, most EMI systems currently do not provide absolute [Formula: see text] values, but erroneous shifts occur due to calibration problems, which hinder a reliable inversion of the data.
Instead of using physical soil data or additional methods to calibrate the EMI data, we have used an efficient and accurate simultaneous calibration and inversion approach to avoid a possible bias of other methods while reducing the acquisition time for the calibration.
By measuring at multiple elevations above the ground surface using a multiconfiguration EMI system, we simultaneously obtain multiplicative and additive calibration factors for each coil configuration plus an inverted layered subsurface electrical conductivity model at the measuring location.
Using synthetic data, we verify our approach.
Experimental data from five different calibration positions along a transect line showed similar calibration results as the data obtained by more elaborate vertical electrical sounding reference measurements.
The synthetic and experimental results demonstrate that the multielevation calibration and inversion approach is a promising tool for quantitative electrical conductivity analyses.
Related Results
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
(Invited) Strategies for Calibration Cost Reduction in Heterogeneous Chemical Sensor Arrays
Introduction
Heterogeneous gas sensor arrays coupled with machine learning algorithms have been proposed for a wide range of applications. However, i...
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Evolution of Antimicrobial Resistance in Community vs. Hospital-Acquired Infections
Abstract
Introduction
Hospitals are high-risk environments for infections. Despite the global recognition of these pathogens, few studies compare microorganisms from community-acqu...
Outcomes Following Allogeneic Stem Cell Transplantation for AML in First Completion Remission Are Comparable between MRD Negative Patients and MRD Positive Patients Receiving Induction Only and Are Superior to MRD Positive Patients Receiving Induction and
Outcomes Following Allogeneic Stem Cell Transplantation for AML in First Completion Remission Are Comparable between MRD Negative Patients and MRD Positive Patients Receiving Induction Only and Are Superior to MRD Positive Patients Receiving Induction and
Background:
Data suggests that the presence of measurable residual disease (MRD) at the time of transplant for AML portends a poor prognosis. The timing of MRD asses...
Application of actuator dynamics inversion techniques to active vibration control systems and shake table testing
Application of actuator dynamics inversion techniques to active vibration control systems and shake table testing
Excessive vibrations problems usually arise in lightweight structures subjected to human actions. The active vibration absorber constitutes an effective solution to mitigate these ...
Inversion Using Adaptive Physics-Based Neural Network: Application to Magnetotelluric Inversion
Inversion Using Adaptive Physics-Based Neural Network: Application to Magnetotelluric Inversion
Abstract
In order to develop a geophysical earth model that is consistent with the measured geophysical data, two types of inversions are commonly used: a physics-ba...
Stochastic Rock Physics Inversion
Stochastic Rock Physics Inversion
Abstract
The purpose of this paper is to introduce a stochastic seismic inversion algorithm based on Markov Chain Monte Carlo Simulation. The suggested inversion ...
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
Radiometric cross-calibration of Sentinel-2B MSI with HY-1C SCS based on the near simultaneous imaging of common ground targets
To simplify the cross-calibration process and improve calibration frequency and accuracy, this paper proposes a cross-calibration method for the multispectral remote sensor Multi-S...

