Does bore size matter?—A comparison of the subjective perception of patient comfort during low field (0.55 Tesla) and standard (1.5 Tesla) MRI imaging

View through CrossRef
The purpose of the present study was to evaluate the subjectively perceived patient comfort during magnetic resonance imaging (MRI) examinations and to assess potential differences between a recently introduced low field MRI scanner and a standard MRI scanner. Among other characteristics, the low field MRI scanner differs from the standard MRI scanner by offering more space (wider bore size of 80 centimeter diameter) and producing less noise, which may influence the patient comfort. In total, 177 patients were surveyed after MRI scans with either the low field MRI scanner (n = 91, MAGNETOM Free.Max, Siemens Healthineers) or the standard MRI scanner (n = 86, MAGNETOM Avanto Fit, Siemens Healthineers). Patients rated different aspects of comfort on a 5 point Likert scale: (a) claustrophobia, (b) comfort of the scanner table, (c) noise level and (d) vertigo during the scanning procedure. In terms of claustrophobia and comfort of the scanner table, patients rated both MRI scanners similar (e.g., mean ratings for claustrophobia: standard MRI scanner = 4.63 ± 1.04, low field MRI scanner = 4.65 ± 1.02). However, when asked for a comparison, patients did favor the more spacious low field MRI scanner. In terms of noise level, the low field MRI scanner was rated significantly better (mean ratings: standard MRI scanner = 3.72 ± 1.46 [median 4 = “rather not unpleasant”], low field MRI scanner = 4.26 ± 1.22 [median 5 = “not unpleasant at all”]). Patients did not perceive any significant difference in terms of vertigo between both MRI scanners. The newly developed low field MRI scanner offers constructional differences compared to standard MRI scanners that are perceived positively by patients. Worth highlighting is the significantly lower noise level and the innovative bore diameter of 80 centimeter, which offers more space to the patients.
Title: Does bore size matter?—A comparison of the subjective perception of patient comfort during low field (0.55 Tesla) and standard (1.5 Tesla) MRI imaging
Description:
The purpose of the present study was to evaluate the subjectively perceived patient comfort during magnetic resonance imaging (MRI) examinations and to assess potential differences between a recently introduced low field MRI scanner and a standard MRI scanner.
Among other characteristics, the low field MRI scanner differs from the standard MRI scanner by offering more space (wider bore size of 80 centimeter diameter) and producing less noise, which may influence the patient comfort.
In total, 177 patients were surveyed after MRI scans with either the low field MRI scanner (n = 91, MAGNETOM Free.
Max, Siemens Healthineers) or the standard MRI scanner (n = 86, MAGNETOM Avanto Fit, Siemens Healthineers).
Patients rated different aspects of comfort on a 5 point Likert scale: (a) claustrophobia, (b) comfort of the scanner table, (c) noise level and (d) vertigo during the scanning procedure.
In terms of claustrophobia and comfort of the scanner table, patients rated both MRI scanners similar (e.
g.
, mean ratings for claustrophobia: standard MRI scanner = 4.
63 ± 1.
04, low field MRI scanner = 4.
65 ± 1.
02).
However, when asked for a comparison, patients did favor the more spacious low field MRI scanner.
In terms of noise level, the low field MRI scanner was rated significantly better (mean ratings: standard MRI scanner = 3.
72 ± 1.
46 [median 4 = “rather not unpleasant”], low field MRI scanner = 4.
26 ± 1.
22 [median 5 = “not unpleasant at all”]).
Patients did not perceive any significant difference in terms of vertigo between both MRI scanners.
The newly developed low field MRI scanner offers constructional differences compared to standard MRI scanners that are perceived positively by patients.
Worth highlighting is the significantly lower noise level and the innovative bore diameter of 80 centimeter, which offers more space to the patients.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
On Flores Island, do "ape-men" still exist? https://www.sapiens.org/biology/flores-island-ape-men/
<span style="font-size:11pt"><span style="background:#f9f9f4"><span style="line-height:normal"><span style="font-family:Calibri,sans-serif"><b><spa...
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
Hubungan Perilaku Pola Makan dengan Kejadian Anak Obesitas
<p><em><span style="font-size: 11.0pt; font-family: 'Times New Roman',serif; mso-fareast-font-family: 'Times New Roman'; mso-ansi-language: EN-US; mso-fareast-langua...
Autonomy on Trial
Autonomy on Trial
Photo by CHUTTERSNAP on Unsplash Abstract This paper critically examines how US bioethics and health law conceptualize patient autonomy, contrasting the rights-based, individualist...
A Comparative Study Between-Small Bore and Large Bore Tubes for Therapeutic Pleural Drainage
A Comparative Study Between-Small Bore and Large Bore Tubes for Therapeutic Pleural Drainage
Introduction: Pleural effusions due to various pulmonary and extra pulmonary causes are common clinical problems. Some pleural diseases require therapeutic pleurocentesis to decomp...
Analysis on the MRI and BAEP  Results of Neonatal Brain with Different Levels of Bilirubin
Analysis on the MRI and BAEP  Results of Neonatal Brain with Different Levels of Bilirubin
Abstract Background:To explore whether there is abnormality of neonatal brains’ MRI and BAEP with different bilirubin levels, and to provide an objective basis for early di...
Analysis on the MRI and BAEP  Results of Neonatal Brain with Different Levels of Bilirubin
Analysis on the MRI and BAEP  Results of Neonatal Brain with Different Levels of Bilirubin
Abstract Background:To explore whether there is abnormality of neonatal brains’ MRI and BAEP with different bilirubin levels, and to provide an objective basis for early di...

Back to Top