Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Evaluation of a flexible bronchoscope prototype designed for bronchoscopy during mechanical ventilation: a proof‐of‐concept study

View through CrossRef
Summary Bronchoscopy during mechanical ventilation of patients' lungs significantly affects ventilation because of partial obstruction of the tracheal tube, and may thus be omitted in the most severely ill patients. It has not previously been possible to reduce the external diameter of the bronchoscope without reducing the diameter of the suction channel, thus reducing the suctioning capacity of the device. We believed that a better‐designed bronchoscope could improve the safety of bronchoscopy in patients whose lungs were ventilated. We designed a flexible bronchoscope prototype with a drumstick‐shaped head consisting of a long, thin proximal portion; a short and large distal portion for camera docking; and a large suction channel throughout the length of the device. The aims of our study were to test the impact of our prototype on mechanical ventilation when inserted into the tracheal tube, and to assess suctioning capacity. We first tested the efficiency of the suction channel, and demonstrated that the suction flow of the prototype was similar to that of conventional adult bronchoscopes. We next evaluated the consequences of bronchoscopy when using the prototype on minute ventilation and intrathoracic pressures during mechanical ventilation: firstly, in vitro using a breathing simulator; and secondly, in vivo using a porcine model of pulmonary ventilation. The insertion of adult bronchoscopes into the tracheal tube immediately impaired the protective ventilation strategy employed, whereas the prototype preserved it. For the first time, we have developed an innovative flexible bronchoscope designed for bronchoscopy during invasive mechanical ventilation, that both preserved the protective ventilation strategy, and enabled efficient suction flow.
Title: Evaluation of a flexible bronchoscope prototype designed for bronchoscopy during mechanical ventilation: a proof‐of‐concept study
Description:
Summary Bronchoscopy during mechanical ventilation of patients' lungs significantly affects ventilation because of partial obstruction of the tracheal tube, and may thus be omitted in the most severely ill patients.
It has not previously been possible to reduce the external diameter of the bronchoscope without reducing the diameter of the suction channel, thus reducing the suctioning capacity of the device.
We believed that a better‐designed bronchoscope could improve the safety of bronchoscopy in patients whose lungs were ventilated.
We designed a flexible bronchoscope prototype with a drumstick‐shaped head consisting of a long, thin proximal portion; a short and large distal portion for camera docking; and a large suction channel throughout the length of the device.
The aims of our study were to test the impact of our prototype on mechanical ventilation when inserted into the tracheal tube, and to assess suctioning capacity.
We first tested the efficiency of the suction channel, and demonstrated that the suction flow of the prototype was similar to that of conventional adult bronchoscopes.
We next evaluated the consequences of bronchoscopy when using the prototype on minute ventilation and intrathoracic pressures during mechanical ventilation: firstly, in vitro using a breathing simulator; and secondly, in vivo using a porcine model of pulmonary ventilation.
The insertion of adult bronchoscopes into the tracheal tube immediately impaired the protective ventilation strategy employed, whereas the prototype preserved it.
For the first time, we have developed an innovative flexible bronchoscope designed for bronchoscopy during invasive mechanical ventilation, that both preserved the protective ventilation strategy, and enabled efficient suction flow.

Related Results

Study of Clinicoradiological Profile of Patients Undergoing Fiberoptic Bronchoscopy
Study of Clinicoradiological Profile of Patients Undergoing Fiberoptic Bronchoscopy
Introduction: Bronchoscopy is a procedure to visualize the tracheobronchial tree. There are three types of Bronchoscopy, rigid, flexible, and virtual Bronchoscopy. Rigid bronchosco...
Flexible Bronchoscope Damage and Repair Costs in a Bronchoscopy Teaching Unit
Flexible Bronchoscope Damage and Repair Costs in a Bronchoscopy Teaching Unit
<i>Background:</i> A significant part of the budget of our bronchoscopy unit represents repair costs for damaged bronchoscopes. <i>Objectives:</i> The purpo...
Hemorrhage Risk of Patients Receiving Bronchoscope Examination or Treatment
Hemorrhage Risk of Patients Receiving Bronchoscope Examination or Treatment
Abstract Background: The type of procedures has changed and become more complex and sophisticated with the development and extensive use of bronchoscopy. This study aimed t...
The factors influencing bronchoscope passing through the glottis
The factors influencing bronchoscope passing through the glottis
Abstract Background Flexible bronchoscopy is an important procedure in respiratory diseases. It is crucial whether bronchoscope can successfully pass through the glottis. T...
The effect of fibreoptic bronchoscopy in acute respiratory distress syndrome: experimental evidence from a lung model
The effect of fibreoptic bronchoscopy in acute respiratory distress syndrome: experimental evidence from a lung model
Summary Flexible bronchoscopy is essential for appropriate care during mechanical ventilation, but can significantly affect mechanical ventilation of the lungs, p...
A systematic review and cost effectiveness analysis of reusable vs. single‐use flexible bronchoscopes
A systematic review and cost effectiveness analysis of reusable vs. single‐use flexible bronchoscopes
Summary The cost effectiveness of reusable vs. single‐use flexible bronchoscopy in the peri‐operative setting has yet to be determined. We therefore aimed to dete...
TU‐H‐202‐02: Applications, Validation, Clinical Endpoints and Opportunities for CT Ventilation
TU‐H‐202‐02: Applications, Validation, Clinical Endpoints and Opportunities for CT Ventilation
CT ventilation imaging is an exciting functional imaging modality that combines four‐dimensional computed tomography (4DCT) and deformable image registration (DIR) to provide exqui...
Invasive Mechanical Ventilation Duration Prediction using Survival Analysis
Invasive Mechanical Ventilation Duration Prediction using Survival Analysis
Abstract Invasive mechanical ventilation is one of the leading life support machines in the intensive care unit (ICU). By identifying the predictors of ventilation ...

Back to Top