Javascript must be enabled to continue!
Assessment of parameters describing the signal delay in the neutral atmosphere derived from VGOS sessions
View through CrossRef
The VLBI Global Observing System (VGOS) is the next generation VLBI system for geodetic and astrometric VLBI. It has been designed by the International VLBI Service for Geodesy and Astrometry (IVS) to improve the accuracy and precision of the estimated geodetic parameters by one order of magnitude compared to the so-called legacy S/X VLBI system. During the VGOS design phase, small-scale and rapid variations in the signal propagation delay caused by the neutral atmosphere were identified as one of the major limiting error sources in terms of accuracy of geodetic VLBI. Performing as many observations as possible per time unit to cover the local sky at the stations as uniformly as possible, has been developed as a strategy to address this topic. The VGOS idea is to achieve this goal by employing fast-slewing radio telescopes ,of typically 12–13 m diameter, that are equipped with broad-band receiving devices of reasonably high sensitivity and digital backends with high sampling capability. Compared to standard S/X legacy VLBI sessions, at least a factor of two in the number of observations per station is currently achieved within operational VGOS sessions (VO). Dedicated VGOS Research and Development (R&D) sessions (VR) achieve an even larger number of observations through minimizing the scan lengths.VGOS is still in its build-up phase and by 2022 the VGOS operational network has reached 10 internationally distributed stations. Among those is the Onsala Space Observatory which is operationally active with its VGOS twin telescopes since 2019. We analyse VGOS sessions of both VO- and VR-series and assess the current ability of VGOS to sense small-scale, rapid variations in the signal propagation delay caused by the neutral atmosphere. We compare the VGOS-derived results to corresponding results from simultaneous observation with co-located instrumentation at VGOS sites, i.e. receiving equipment for Global Navigation Satellite System (GNSS) observations. For the Onsala station we compare also to the results derived from the ground-based microwave radiometer.
Title: Assessment of parameters describing the signal delay in the neutral atmosphere derived from VGOS sessions
Description:
The VLBI Global Observing System (VGOS) is the next generation VLBI system for geodetic and astrometric VLBI.
It has been designed by the International VLBI Service for Geodesy and Astrometry (IVS) to improve the accuracy and precision of the estimated geodetic parameters by one order of magnitude compared to the so-called legacy S/X VLBI system.
During the VGOS design phase, small-scale and rapid variations in the signal propagation delay caused by the neutral atmosphere were identified as one of the major limiting error sources in terms of accuracy of geodetic VLBI.
Performing as many observations as possible per time unit to cover the local sky at the stations as uniformly as possible, has been developed as a strategy to address this topic.
The VGOS idea is to achieve this goal by employing fast-slewing radio telescopes ,of typically 12–13 m diameter, that are equipped with broad-band receiving devices of reasonably high sensitivity and digital backends with high sampling capability.
Compared to standard S/X legacy VLBI sessions, at least a factor of two in the number of observations per station is currently achieved within operational VGOS sessions (VO).
Dedicated VGOS Research and Development (R&D) sessions (VR) achieve an even larger number of observations through minimizing the scan lengths.
VGOS is still in its build-up phase and by 2022 the VGOS operational network has reached 10 internationally distributed stations.
Among those is the Onsala Space Observatory which is operationally active with its VGOS twin telescopes since 2019.
We analyse VGOS sessions of both VO- and VR-series and assess the current ability of VGOS to sense small-scale, rapid variations in the signal propagation delay caused by the neutral atmosphere.
We compare the VGOS-derived results to corresponding results from simultaneous observation with co-located instrumentation at VGOS sites, i.
e.
receiving equipment for Global Navigation Satellite System (GNSS) observations.
For the Onsala station we compare also to the results derived from the ground-based microwave radiometer.
Related Results
VGOS Intensives Ishioka-Onsala
VGOS Intensives Ishioka-Onsala
<p>The VLBI Global Observing System (VGOS) is the VLBI contribution to GGOS.&#160;During the last years, several VGOS stations have been established, the VGOS...
VGOS observing strategy for 202
VGOS observing strategy for 202
The VLBI Global Observing System (VGOS) entered operational service in 2020 with a small, northern-hemisphere-dominated network and a modest observing cadence constrained primarily...
Rethinking operational VGOS observations
Rethinking operational VGOS observations
The VLBI Global Observing System (VGOS) was created to meet the ambitious requirements set by the Global Geodetic Observing System (GGOS). Its primary objective is achieving millim...
Estimation of VGOS Station Coordinates
Estimation of VGOS Station Coordinates
<p>With the number of available VGOS (VLBI Global Observing System) sessions rising, precise coordinates for the participating stations become more important. While s...
Tropospheric Parameters Derived From Co-located Instrumentation at the Onsala Space Observatory
Tropospheric Parameters Derived From Co-located Instrumentation at the Onsala Space Observatory
Observations performed with ground-based space geodetic and remote sensing techniques are sensitive to the amount of water vapour in the neutral atmosphere. Corresponding parameter...
Microwave radiometer observations for VGOS data processing
Microwave radiometer observations for VGOS data processing
Since mid 2023, the Onsala Space Observatory is operating a new modern microwave radiometer, Greta, which is a commercial product of type HATPRO-G5. It is co-located with the other...
Exploration of VGOS station position estimates and the signals within
Exploration of VGOS station position estimates and the signals within
Over the past decade, the IVS has undertaken enormous efforts to modernize its infrastructure under the VGOS (VLBI global observing system) umbrella in order to meet the objectives...
Observing UT1-UTC with VGOS
Observing UT1-UTC with VGOS
Abstract
We present rst results of UT1-UTC determinations using the VLBI Global Observing System (VGOS). During December 2019 through February 2020 a series of 1 hour long ...

