Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Microfluidic extensional rheometry using stagnation point flow

View through CrossRef
Characterization of the extensional rheometry of fluids with complex microstructures is of great relevance to the optimization of a wide range of industrial applications and for understanding various natural processes, biological functions, and diseases. However, quantitative measurement of the extensional properties of complex fluids has proven elusive to researchers, particularly in the case of low viscosity, weakly elastic fluids. For some time, microfluidic platforms have been recognized as having the potential to fill this gap and various approaches have been proposed. This review begins with a general discussion of extensional viscosity and the requirements of an extensional rheometer, before various types of extensional rheometers (particularly those of microfluidic design) are critically discussed. A specific focus is placed on microfluidic stagnation point extensional flows generated by cross-slot type devices, for which some important developments have been reported during the last 10 years. Additional emphasis is placed on measurements made on relevant biological fluids. Finally, the operating limits of the cross-slot extensional rheometer (chiefly imposed by the onset of elastic and inertial flow instabilities) are discussed.
Title: Microfluidic extensional rheometry using stagnation point flow
Description:
Characterization of the extensional rheometry of fluids with complex microstructures is of great relevance to the optimization of a wide range of industrial applications and for understanding various natural processes, biological functions, and diseases.
However, quantitative measurement of the extensional properties of complex fluids has proven elusive to researchers, particularly in the case of low viscosity, weakly elastic fluids.
For some time, microfluidic platforms have been recognized as having the potential to fill this gap and various approaches have been proposed.
This review begins with a general discussion of extensional viscosity and the requirements of an extensional rheometer, before various types of extensional rheometers (particularly those of microfluidic design) are critically discussed.
A specific focus is placed on microfluidic stagnation point extensional flows generated by cross-slot type devices, for which some important developments have been reported during the last 10 years.
Additional emphasis is placed on measurements made on relevant biological fluids.
Finally, the operating limits of the cross-slot extensional rheometer (chiefly imposed by the onset of elastic and inertial flow instabilities) are discussed.

Related Results

First Clinical Description of Coagulation of Whole Blood with Resonant Acoustic Rheometry
First Clinical Description of Coagulation of Whole Blood with Resonant Acoustic Rheometry
Background/Objectives: The timely evaluation of blood clot formation and breakdown is essential in the care of patients with severe bleeding or critical illness. Resonant acoustic ...
Threads of time
Threads of time
This thesis advances the fundamental understanding of dilute polymer solution rheology through systematic investigation of extensional flow behavior, with particular focus on polye...
Pre-Messinian Extensional Tectonics and exploration potential of related structures; in Central Nile Delta Basin, Egypt
Pre-Messinian Extensional Tectonics and exploration potential of related structures; in Central Nile Delta Basin, Egypt
Abstract This paper discusses the exploration potential of extensional structures in pre-Messinian formations in central Nile Delta Basin. The study aims at detailed...
Extensional viscosity of some food hydrocolloids
Extensional viscosity of some food hydrocolloids
Abstract Conventional rheological techniques such as steady shear viscosity and dynamic oscillatory rheometry have long been used to characterize differences between...
Boundary Layer Flow of Dusty Ferrofluid: A Comparative Analysis of Stagnation Flow Influence
Boundary Layer Flow of Dusty Ferrofluid: A Comparative Analysis of Stagnation Flow Influence
This research examines the characteristics of the boundary layer in the occurrence of dust particles within the ferrofluid boundary layer, aiming to understand the impact of stagna...
The rheometry approach in modern soil studies: a review
The rheometry approach in modern soil studies: a review
Digital soil rheometry is a relatively new and rapidly developing research direction that currently occupies a small niche in soil and agrophysics studies. This paper presents a re...
Electrical contactless microfluidic flow quantification
Electrical contactless microfluidic flow quantification
Precise sensing of microfluidic flow is essential to advancing lab-on-a-chip development and the downstream medical applications. Contactless microfluidic flow interrogation is non...

Back to Top