Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

First Clinical Description of Coagulation of Whole Blood with Resonant Acoustic Rheometry

View through CrossRef
Background/Objectives: The timely evaluation of blood clot formation and breakdown is essential in the care of patients with severe bleeding or critical illness. Resonant acoustic rheometry is a novel, non-contact ultrasound method that measures changes in the viscoelastic properties of blood in a standard microplate format. Here, we present the first clinical description of whole blood coagulation and fibrinolysis assessed with resonant acoustic rheometry, with paired thromboelastography measurements for comparison. Methods: In this retrospective analysis, whole blood samples from three critically ill patients were divided and tested under four different conditions that included a control mixture, kaolin activation, tissue factor activation, and a tissue factor mixture supplemented with tissue plasminogen activator. The resonant acoustic rheometry system obtained real time measurements of resonant surface waves and displacements from the samples. Heat maps and spectrograms of the resonant surface waves were analyzed to determine the onset of clotting, the rate of viscoelastic stiffening, the time to maximum rigidity, and the onset as well as magnitude of fibrinolysis. These measurements were compared with thromboelastography reaction time, clot strength, fibrinogen contribution, and lysis values. Results: Resonant acoustic rheometry detected reproducible transitions from liquid to clot and from clot to lysis in all samples. Activator-dependent changes in clot initiation and propagation matched the expected hierarchy observed in thromboelastography. Significantly, samples exposed to tissue plasminogen activator demonstrated a clear fall in resonant frequency and a corresponding rise in surface displacement that reflected fibrinolysis. The technique also reproduced clinically meaningful patterns of hemostasis that aligned with each patient’s underlying disease. Conclusions: Whole blood clotting can be measured with resonant acoustic rheometry in a manner that aligns with established clinical assays. These results suggest strong potential for future use of resonant acoustic rheometry as a cost-effective, complementary platform for rapid, scalable, and clinically informative hemostatic assessment.
Title: First Clinical Description of Coagulation of Whole Blood with Resonant Acoustic Rheometry
Description:
Background/Objectives: The timely evaluation of blood clot formation and breakdown is essential in the care of patients with severe bleeding or critical illness.
Resonant acoustic rheometry is a novel, non-contact ultrasound method that measures changes in the viscoelastic properties of blood in a standard microplate format.
Here, we present the first clinical description of whole blood coagulation and fibrinolysis assessed with resonant acoustic rheometry, with paired thromboelastography measurements for comparison.
Methods: In this retrospective analysis, whole blood samples from three critically ill patients were divided and tested under four different conditions that included a control mixture, kaolin activation, tissue factor activation, and a tissue factor mixture supplemented with tissue plasminogen activator.
The resonant acoustic rheometry system obtained real time measurements of resonant surface waves and displacements from the samples.
Heat maps and spectrograms of the resonant surface waves were analyzed to determine the onset of clotting, the rate of viscoelastic stiffening, the time to maximum rigidity, and the onset as well as magnitude of fibrinolysis.
These measurements were compared with thromboelastography reaction time, clot strength, fibrinogen contribution, and lysis values.
Results: Resonant acoustic rheometry detected reproducible transitions from liquid to clot and from clot to lysis in all samples.
Activator-dependent changes in clot initiation and propagation matched the expected hierarchy observed in thromboelastography.
Significantly, samples exposed to tissue plasminogen activator demonstrated a clear fall in resonant frequency and a corresponding rise in surface displacement that reflected fibrinolysis.
The technique also reproduced clinically meaningful patterns of hemostasis that aligned with each patient’s underlying disease.
Conclusions: Whole blood clotting can be measured with resonant acoustic rheometry in a manner that aligns with established clinical assays.
These results suggest strong potential for future use of resonant acoustic rheometry as a cost-effective, complementary platform for rapid, scalable, and clinically informative hemostatic assessment.

Related Results

[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Subjective audiometric measures in individuals with repeated acoustic trauma in the combat zone
Subjective audiometric measures in individuals with repeated acoustic trauma in the combat zone
Intense sound exposure that exceeds the pain threshold of human auditory sensitivity, known as acoustic trauma, causes significant and extensive changes in the auditory system. Thr...
Coagulation factor IX regulates cell migration and adhesion in vitro
Coagulation factor IX regulates cell migration and adhesion in vitro
AbstractCoagulation factor IX is thought to circulate in the blood as an inactive zymogen before being activated in the coagulation process. The effect of coagulation factor IX on ...
Erratum
Erratum
Erratum: “Separation of Resonant and Non-Resonant Components-Part I: Sound Reduction Index” Jeffrey Mahn There was an error...
Bubble rupture & viability of red blood cells under resonant acoustic standing waves
Bubble rupture & viability of red blood cells under resonant acoustic standing waves
Objective: The presentation of a novel prospective treatment for scenarios where bubble presence in the bloodstream poses a clinical risk. The method relies on generating resonant ...
Research Progress of Locally Resonance Acoustic Metamaterials
Research Progress of Locally Resonance Acoustic Metamaterials
Bragg scattering phonon crystal and locally resonant acoustic metamaterials were introduced. In order to generate noise reduction, the lattice constant of Bragg scattering phonon c...
Resonant Object Interface: An Acoustic Input Device for Nuanced, Embodied Interaction with Music Software
Resonant Object Interface: An Acoustic Input Device for Nuanced, Embodied Interaction with Music Software
<p><strong>The Resonant Object Interface is a novel sensing system that combines vibration exciters, contact microphones and resonant objects to create a unique, nuance...

Back to Top