Javascript must be enabled to continue!
Fault Diagnosis and Tolerant Control of Three-Level Neutral-Point Clamped Inverters in Motor Drives
View through CrossRef
This paper presents an extension theory-based assessment method to perform fault diagnosis for inverters in motor driving systems. First, a three-level neutral-point clamped (NPC) inverter is created using the PSIM software package to simulate faults for any power transistor in the NPC-type inverter. Fast Fourier transformation is used to transform the line current signals in the time domain into a spectrum in the frequency domain for analysis of the corresponding spectrum of features of the inverter for faults with different power transistors. Then, the relationships between fault types and specific spectra are established as characteristics for the extension assessment method, which is then used to create a smart fault diagnosis system for inverters. Fault-tolerant control (FTC) is used here when the rated output of a faulty inverter is decreased in order to maintain balanced output in three phases by changing the framework of the transistor connection. This is performed to reinforce the reliability of the inverter. Finally, by the simulation and experimental results, the feasibility of the proposed smart fault diagnosis system is confirmed. The proposed fault diagnosis method is advantageous due to its minimal use of data and lack of a learning process, which thereby reduces the fault diagnosis time and makes the method easily used in practice. The proposed fault-tolerant control strategy allows both online and smooth switching in the wiring structure of the inverter.
Title: Fault Diagnosis and Tolerant Control of Three-Level Neutral-Point Clamped Inverters in Motor Drives
Description:
This paper presents an extension theory-based assessment method to perform fault diagnosis for inverters in motor driving systems.
First, a three-level neutral-point clamped (NPC) inverter is created using the PSIM software package to simulate faults for any power transistor in the NPC-type inverter.
Fast Fourier transformation is used to transform the line current signals in the time domain into a spectrum in the frequency domain for analysis of the corresponding spectrum of features of the inverter for faults with different power transistors.
Then, the relationships between fault types and specific spectra are established as characteristics for the extension assessment method, which is then used to create a smart fault diagnosis system for inverters.
Fault-tolerant control (FTC) is used here when the rated output of a faulty inverter is decreased in order to maintain balanced output in three phases by changing the framework of the transistor connection.
This is performed to reinforce the reliability of the inverter.
Finally, by the simulation and experimental results, the feasibility of the proposed smart fault diagnosis system is confirmed.
The proposed fault diagnosis method is advantageous due to its minimal use of data and lack of a learning process, which thereby reduces the fault diagnosis time and makes the method easily used in practice.
The proposed fault-tolerant control strategy allows both online and smooth switching in the wiring structure of the inverter.
Related Results
Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems.
Concerning fault detection, interv...
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Abstract:Little attention had been paid to the intracontinental strike‐slip faults of the Tibetan Plateau. Since the discovery of the Longriba fault using re‐measured GPS data in 2...
Data-driven Fault Diagnosis for Cyber-Physical Systems
Data-driven Fault Diagnosis for Cyber-Physical Systems
The concept of Industry 4.0 uses cyber-physical systems and the Internet of Things to create "smart factories" that enable automated and connected production. However, the complex ...
Modelització i control d'accionaments elèctrics.
Modelització i control d'accionaments elèctrics.
L'actual situació energètica demanda cada cop més d'aplicacions que redueixin el consum energètic. A nivell d'energia elèctrica, i de la conversió d'aquesta a energia mecànica, els...
Fault Tolerant Control of Five-Phase Induction Motor Drive
Fault Tolerant Control of Five-Phase Induction Motor Drive
The fault-tolerant capability of multiphase induction motor (IM) drives without adding extra hardware has been an interesting research subject in recent times. Regardless of the ap...
A unified SVPWM fault tolerant control algorithm for single leg fault reconstruction topology of two-level inverter
A unified SVPWM fault tolerant control algorithm for single leg fault reconstruction topology of two-level inverter
AbstractTo improve the reliability of Two-level three phase voltage source inverters, a uniform fault tolerant strategy based on space vector pulse width modulation is proposed for...
Low-temperature thermochronology of fault zones
Low-temperature thermochronology of fault zones
<p>Thermal signatures as well as timing of fault motions can be constrained by thermochronological analyses of fault-zone rocks (e.g., Tagami, 2012, 2019).&#1...
Structural Characteristics and Evolution Mechanism of Paleogene Faults in the Central Dongying Depression, Bohai Bay Basin
Structural Characteristics and Evolution Mechanism of Paleogene Faults in the Central Dongying Depression, Bohai Bay Basin
Abstract
This study used the growth index, fault activity rate and fault distance burial depth curve methods to analyze the characteristics of fault activity in the central...

