Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A unified SVPWM fault tolerant control algorithm for single leg fault reconstruction topology of two-level inverter

View through CrossRef
AbstractTo improve the reliability of Two-level three phase voltage source inverters, a uniform fault tolerant strategy based on space vector pulse width modulation is proposed for different leg faults. The reconstructed topologies of inverters with different bridge arm faults are different, which makes the basic voltage vector phase of each reconstructed topology inconsistent, resulting in different calculations. Therefore, the coordinate transformation is applied to place the basic voltage vectors of each reconstructed topology on the synchronous stationary αβ coordinate system so that the calculations of the reconstructed topology under different bridge arm faults are unified, thus reducing the complexity of fault-tolerant control. Aiming at the three-phase current asymmetry caused by the neutral point voltage oscillation in inverter topology reconstruction, a transient compensation method of neutral point voltage offset for the α-axis component of the reference voltage vector is introduced to suppress the adverse effects. The compensation method directly offers a neutral point voltage offset value after Clarke transformation and corrects the α-axis component of the reference voltage vector, avoiding the integral calculation in the conventional voltage compensation algorithm. The correctness and effectiveness of the proposed fault-tolerant control strategy are verified experimentally.
Springer Science and Business Media LLC
Title: A unified SVPWM fault tolerant control algorithm for single leg fault reconstruction topology of two-level inverter
Description:
AbstractTo improve the reliability of Two-level three phase voltage source inverters, a uniform fault tolerant strategy based on space vector pulse width modulation is proposed for different leg faults.
The reconstructed topologies of inverters with different bridge arm faults are different, which makes the basic voltage vector phase of each reconstructed topology inconsistent, resulting in different calculations.
Therefore, the coordinate transformation is applied to place the basic voltage vectors of each reconstructed topology on the synchronous stationary αβ coordinate system so that the calculations of the reconstructed topology under different bridge arm faults are unified, thus reducing the complexity of fault-tolerant control.
Aiming at the three-phase current asymmetry caused by the neutral point voltage oscillation in inverter topology reconstruction, a transient compensation method of neutral point voltage offset for the α-axis component of the reference voltage vector is introduced to suppress the adverse effects.
The compensation method directly offers a neutral point voltage offset value after Clarke transformation and corrects the α-axis component of the reference voltage vector, avoiding the integral calculation in the conventional voltage compensation algorithm.
The correctness and effectiveness of the proposed fault-tolerant control strategy are verified experimentally.

Related Results

Muscle Metabolism during Exercise in Hemiparetic Patients
Muscle Metabolism during Exercise in Hemiparetic Patients
1. A group of eight male patients with moderate hemiparesis was studied at rest and during 40 min of exercise on four occasions. Both two-leg and one-leg exercise were performed an...
Integration Techniques of Fault Detection and Isolation Using Interval Observers
Integration Techniques of Fault Detection and Isolation Using Interval Observers
An interval observer has been illustrated to be a suitable approach to detect and isolate faults affecting complex dynamical industrial systems. Concerning fault detection, interv...
A Novel SVPWM Algorithm Considering Neutral - Point Potential Balancing for Three - Level NPC Inverter
A Novel SVPWM Algorithm Considering Neutral - Point Potential Balancing for Three - Level NPC Inverter
For three-level inverter, complexity of control strategy and neutral-point potential imbalance problem of DC side is the bottleneck restricting its application. In order to solve t...
Fault Diagnosis and Tolerant Control of Three-Level Neutral-Point Clamped Inverters in Motor Drives
Fault Diagnosis and Tolerant Control of Three-Level Neutral-Point Clamped Inverters in Motor Drives
This paper presents an extension theory-based assessment method to perform fault diagnosis for inverters in motor driving systems. First, a three-level neutral-point clamped (NPC) ...
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Decomposition and Evolution of Intracontinental Strike‐Slip Faults in Eastern Tibetan Plateau
Abstract:Little attention had been paid to the intracontinental strike‐slip faults of the Tibetan Plateau. Since the discovery of the Longriba fault using re‐measured GPS data in 2...
A Novel Single-Phase Five-Level Current-Source Inverter Topology
A Novel Single-Phase Five-Level Current-Source Inverter Topology
Recent technological advances have renewed the research interest in current-source inverters (CSIs). Nonetheless, CSI research still falls behind its voltage-source counterpart wit...
RESEARCH AND DESIGN OF GRID-CONNECTED INVERTER IN PHOTOVOLTAIC SYSTEM WITH SVPWM TECHNIQUE
RESEARCH AND DESIGN OF GRID-CONNECTED INVERTER IN PHOTOVOLTAIC SYSTEM WITH SVPWM TECHNIQUE
This paper presents the design and simulation of three phase grid-connected inverter for photovoltaic systems with power ratings up to 5 kW. In this research, the application of Sp...
Student oriented implementation of SVPWM using LabVIEW and myRio
Student oriented implementation of SVPWM using LabVIEW and myRio
<div>In this paper, an approach for helping undergraduate students understand complex algorithms through structured flowcharts (SFCs) and their implementation using graphical...