Javascript must be enabled to continue!
Study on the Structural Behavior of Circular Macro-Synthetic-Reinforced-Concrete Columns Reinforced by Polymeric Bars
View through CrossRef
This study investigates the axial compression performance and theoretical analysis of macro-synthetic-fiber-reinforced
concrete (MSFRC) columns reinforced with carbon-fiber-reinforced polymer (CFRP) bars. A comprehensive testing program was
developed to assess and compare the structural behavior of columns made with both traditional and advanced materials. Key variables
included plain concrete (PC), macro-synthetic-reinforced concrete (MSRC), longitudinal steel/CFRP bars, and variations in the steel
spiral/hoop bar pitch. Sixteen specimens were fabricated in four groups (CRPC, CRMSP, SRPC, and SRMSP) to capture these
variations. The results showed consistent failure modes across all specimens, with good alignment between experimental outcomes
and theoretical predictions. Axial compression strengths for CRPC and CRMSP specimens reached, on average, 89.57% and 91.83%
of the strengths observed in SRPC and SRFC specimens, respectively. The ductility index (DI) of CRCC and CRMSP columns was
8.54% and 12.14% higher than that of their SRPC and SRMSP counterparts. Furthermore, the CRMSP and SRMSP columns
demonstrated higher axial strain than their CRCC and SRPC equivalents, with average increases of 19% and 11% under peak
compression loads, respectively. Although North American codes currently do not propose the use of polymeric bars as compressive
elements in reinforced concrete (RC) and do not provide specific design guidelines [5-8], the proposed theoretical model accurately
predicted the performance of the tested columns. The test result of compression strength was close to proposed equations considering
the axial contribution of CFRP longitudinal bars and integrated additional factors such as steel spiral/hoop reinforcement, volumetric
reinforcement ratios, and concrete type after concrete cover spalling.
Title: Study on the Structural Behavior of Circular Macro-Synthetic-Reinforced-Concrete Columns Reinforced by Polymeric Bars
Description:
This study investigates the axial compression performance and theoretical analysis of macro-synthetic-fiber-reinforced
concrete (MSFRC) columns reinforced with carbon-fiber-reinforced polymer (CFRP) bars.
A comprehensive testing program was
developed to assess and compare the structural behavior of columns made with both traditional and advanced materials.
Key variables
included plain concrete (PC), macro-synthetic-reinforced concrete (MSRC), longitudinal steel/CFRP bars, and variations in the steel
spiral/hoop bar pitch.
Sixteen specimens were fabricated in four groups (CRPC, CRMSP, SRPC, and SRMSP) to capture these
variations.
The results showed consistent failure modes across all specimens, with good alignment between experimental outcomes
and theoretical predictions.
Axial compression strengths for CRPC and CRMSP specimens reached, on average, 89.
57% and 91.
83%
of the strengths observed in SRPC and SRFC specimens, respectively.
The ductility index (DI) of CRCC and CRMSP columns was
8.
54% and 12.
14% higher than that of their SRPC and SRMSP counterparts.
Furthermore, the CRMSP and SRMSP columns
demonstrated higher axial strain than their CRCC and SRPC equivalents, with average increases of 19% and 11% under peak
compression loads, respectively.
Although North American codes currently do not propose the use of polymeric bars as compressive
elements in reinforced concrete (RC) and do not provide specific design guidelines [5-8], the proposed theoretical model accurately
predicted the performance of the tested columns.
The test result of compression strength was close to proposed equations considering
the axial contribution of CFRP longitudinal bars and integrated additional factors such as steel spiral/hoop reinforcement, volumetric
reinforcement ratios, and concrete type after concrete cover spalling.
Related Results
Enhancing structural behaviour of polypropylene fibre concrete columns longitudinally reinforced with fibreglass bars
Enhancing structural behaviour of polypropylene fibre concrete columns longitudinally reinforced with fibreglass bars
Abstract
The research aims to study the behaviour of concrete columns reinforced with fibreglass as bars exposed to seawater. Firstly, hardened concrete properties a...
Structural Behavior of Circular Macro-Synthetic-Fiber Concrete Columns Reinforced by CFRP Bars
Structural Behavior of Circular Macro-Synthetic-Fiber Concrete Columns Reinforced by CFRP Bars
This study investigates the axial compression performance and theoretical analysis of macro-synthetic-fiber-reinforced concrete (MSFRC) columns reinforced with carbon-fiber-reinfor...
Strength analysis of concrete-encased cellular steel columns
Strength analysis of concrete-encased cellular steel columns
This research investigates the compression behavior of bare cellular steel columns and concrete-encased cellular steel (CECS) columns subjected to concentric and eccentric loadings...
A Comprehensive Review of the Effects of Different Simulated Environmental Conditions and Hybridization Processes on the Mechanical Behavior of Different FRP Bars
A Comprehensive Review of the Effects of Different Simulated Environmental Conditions and Hybridization Processes on the Mechanical Behavior of Different FRP Bars
When it comes to sustainability, steel rebar corrosion has always been a big issue, especially when they are exposed to harsh environmental conditions, such as marine and coastal e...
Axial Compression Capacity of Concrete Columns Reinforced With Corrosion-Resistant Metallic Reinforcement
Axial Compression Capacity of Concrete Columns Reinforced With Corrosion-Resistant Metallic Reinforcement
Abstract
Axial compression performance of concrete columns reinforced with 2304 duplex stainless bars and spirals, carbon steel bars and spirals, and 316L stainless steel c...
Axial Compression Capacity of Concrete Columns Reinforced with Corrosion-Resistant Metallic Reinforcement
Axial Compression Capacity of Concrete Columns Reinforced with Corrosion-Resistant Metallic Reinforcement
Abstract
Axial compression performance of concrete columns reinforced with 2304 solid stainless bars and spirals, carbon steel bars and spirals, and 316L stainless steel cl...
He found use for reinforced concrete where, it would seem, this material has no place
He found use for reinforced concrete where, it would seem, this material has no place
Introduction. The article is devoted to an employee of the Research Institute of Reinforced Concrete, Doctor of Technical Sciences, Professor I.G. Ludkovsky, a specialist in the fi...
Numerical modeling of reinforced concrete columns strengthened by external steel collars and steel bars
Numerical modeling of reinforced concrete columns strengthened by external steel collars and steel bars
This study investigated numerical modeling for reinforced concrete columns strengthened by external hollow structural section (HSS) steel collars and external steel bars. The main ...

