Javascript must be enabled to continue!
The Effect of Intra-Aortic Balloon Counterpulsation on Coronary Blood Flow Velocity Distal to Coronary Artery Stenoses
View through CrossRef
Despite the accepted clinical benefit of intra-aortic balloon counterpulsation (IABC), the physiologic explanation for its benefit remains controversial. Indirect methods of measuring coronary blood flow during IABC in obstructive coronary disease have yielded conflicting results. The direct measurement of coronary blood flow velocity distal to sites of stenoses by methods that do not potentially impede flow has not been previously reported. The aim of our study was to determine the effect of IABC on coronary blood flow velocity distal to a coronary stenosis by employing a method that would not impede flow through the stenosis. In an open-chest canine model, phasic and mean left anterior descending coronary artery flow velocities distal to varying degrees of stenosis were continuously measured by an epicardial Doppler probe with and without counterpulsation. All hemodynamic parameters were recorded in the absence of stenosis (n = 5) and the presence of subcritical (n = 5) and critical stenoses (n = 5). Heart rate was not affected by counterpulsation. Systolic blood pressure and rate-pressure product declined at all times with IABC. Compared to baseline, peak aortic diastolic pressure was augmented by an average of 24 mm Hg during IABC (p < 0.05). However, mean coronary artery flow velocities remained unchanged (101, 103 and 98% of baseline for no stenosis, subcritical stenosis and critical stenosis, respectively; p > 0.05 compared to baseline). Peak diastolic flow velocities were 106,102 and 96% of baseline for no stenosis, subcritical and critical stenoses, respectively (p > 0.05). Despite the augmentation of peak diastolic pressure, distal coronary blood flow velocity was not increased by IABC in this canine model, irrespective of the severity of proximal coronary stenosis. These data suggest that augmentation of coronary artery flow distal to sites of stenoses is not primarily responsible for the clinical benefit observed when IABC is used in the setting of obstructive coronary artery disease. The reduction in afterload and myocardial oxygen demand observed in this model agrees with previous studies and likely accounts, at least in part, for the positive clinical results with IABC.
Title: The Effect of Intra-Aortic Balloon Counterpulsation on Coronary Blood Flow Velocity Distal to Coronary Artery Stenoses
Description:
Despite the accepted clinical benefit of intra-aortic balloon counterpulsation (IABC), the physiologic explanation for its benefit remains controversial.
Indirect methods of measuring coronary blood flow during IABC in obstructive coronary disease have yielded conflicting results.
The direct measurement of coronary blood flow velocity distal to sites of stenoses by methods that do not potentially impede flow has not been previously reported.
The aim of our study was to determine the effect of IABC on coronary blood flow velocity distal to a coronary stenosis by employing a method that would not impede flow through the stenosis.
In an open-chest canine model, phasic and mean left anterior descending coronary artery flow velocities distal to varying degrees of stenosis were continuously measured by an epicardial Doppler probe with and without counterpulsation.
All hemodynamic parameters were recorded in the absence of stenosis (n = 5) and the presence of subcritical (n = 5) and critical stenoses (n = 5).
Heart rate was not affected by counterpulsation.
Systolic blood pressure and rate-pressure product declined at all times with IABC.
Compared to baseline, peak aortic diastolic pressure was augmented by an average of 24 mm Hg during IABC (p < 0.
05).
However, mean coronary artery flow velocities remained unchanged (101, 103 and 98% of baseline for no stenosis, subcritical stenosis and critical stenosis, respectively; p > 0.
05 compared to baseline).
Peak diastolic flow velocities were 106,102 and 96% of baseline for no stenosis, subcritical and critical stenoses, respectively (p > 0.
05).
Despite the augmentation of peak diastolic pressure, distal coronary blood flow velocity was not increased by IABC in this canine model, irrespective of the severity of proximal coronary stenosis.
These data suggest that augmentation of coronary artery flow distal to sites of stenoses is not primarily responsible for the clinical benefit observed when IABC is used in the setting of obstructive coronary artery disease.
The reduction in afterload and myocardial oxygen demand observed in this model agrees with previous studies and likely accounts, at least in part, for the positive clinical results with IABC.
Related Results
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract
Introduction
Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Short‐term external counterpulsation augments cerebral blood flow and tissue oxygenation in chronic cerebrovascular occlusive disease
Short‐term external counterpulsation augments cerebral blood flow and tissue oxygenation in chronic cerebrovascular occlusive disease
Background and purposeExternal counterpulsation improves cerebral perfusion velocity in acute stroke and may stimulate collateral artery growth. However, whether (non‐acute) at‐ris...
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Abstract
Background
Although an association between elevated blood pressure and risk of aortic aneurysm is established, f...
Accuracy of MSCT Coronary Angiography with 64 Row CT Scanner—Facing the Facts
Accuracy of MSCT Coronary Angiography with 64 Row CT Scanner—Facing the Facts
Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitat...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract
Introduction
Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
A study on risk factors of coronary artery disease in Chong Qing city
A study on risk factors of coronary artery disease in Chong Qing city
Objective
To investigate the relationship between risk factors and coronary artery disease in Chong Qing city, and to provide scientific basis for preventing and ...
Valvuloplasty Balloon Catheter Sizing Approach for Calcified Aortic Valve with Different Annulus Ratios
Valvuloplasty Balloon Catheter Sizing Approach for Calcified Aortic Valve with Different Annulus Ratios
Transcatheter aortic valve implantation (TAVI) is re- garded as the option of preference minimally invasive intervention to treat high-risk patients with aortic steno- sis, whic...

