Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Assessment of Postoperative Analgesic Efficacy and Animal Well-Being Using a Novel Triaxial Accelerometer Device, the Rodent Fitbit-Like Telemetry Device

View through CrossRef
Accurate postoperative pain management is crucial for good animal welfare and science. We sought to evaluate mouse postoperative pain management efficacy by measuring activity using a novel triaxial acceleration device—the Rodent Fitbit-like telemetry device (RFB)—to monitor home cage activity. To determine if analgesics impacted activity levels, we evaluated activity in C57BL/6 male and female mice ( n = 6) that were attached with the RFB and administered EthiqaXR (XR; 3.25 mg/kg), meloxicam sustained release (MSR; 6 mg/kg), combined XR/MSR, or bupivacaine (5 mg/mL) compared with control mice provided sterile saline (5 mL/kg) subcutaneously. Activity in XR/MSR and XR-treated mice was significantly increased on night 0 (N0) but only trended downward from N2 to N4 compared with baseline. No significant changes in activity were detected after administration of MSR, bupivacaine, and saline. We examined the effective analgesic period of XR, MSR, XR/MSR, and bupivacaine based on electric von Frey and the RFB using a hind paw incision pain model in C57BL/6 male ( n = 8) and female mice ( n = 7) attached with the RFB. Preoperative XR and XR/MSR mice had reduced pain based on von Frey with no reduction in activity based on the RFB compared with other treatment groups. Only mice provided saline demonstrated a significant decrease in activity on N0, suggesting limited duration of spontaneous pain elicited from the minor pain model. In summary, activity was an effective and sensitive indicator for detecting pain using a paw incision pain model in C57BL/6 mice within the first 24 h postsurgery. Additional studies using a major operative procedure should be performed to determine the effectiveness of activity as a pain detection indicator.
Title: Assessment of Postoperative Analgesic Efficacy and Animal Well-Being Using a Novel Triaxial Accelerometer Device, the Rodent Fitbit-Like Telemetry Device
Description:
Accurate postoperative pain management is crucial for good animal welfare and science.
We sought to evaluate mouse postoperative pain management efficacy by measuring activity using a novel triaxial acceleration device—the Rodent Fitbit-like telemetry device (RFB)—to monitor home cage activity.
To determine if analgesics impacted activity levels, we evaluated activity in C57BL/6 male and female mice ( n = 6) that were attached with the RFB and administered EthiqaXR (XR; 3.
25 mg/kg), meloxicam sustained release (MSR; 6 mg/kg), combined XR/MSR, or bupivacaine (5 mg/mL) compared with control mice provided sterile saline (5 mL/kg) subcutaneously.
Activity in XR/MSR and XR-treated mice was significantly increased on night 0 (N0) but only trended downward from N2 to N4 compared with baseline.
No significant changes in activity were detected after administration of MSR, bupivacaine, and saline.
We examined the effective analgesic period of XR, MSR, XR/MSR, and bupivacaine based on electric von Frey and the RFB using a hind paw incision pain model in C57BL/6 male ( n = 8) and female mice ( n = 7) attached with the RFB.
Preoperative XR and XR/MSR mice had reduced pain based on von Frey with no reduction in activity based on the RFB compared with other treatment groups.
Only mice provided saline demonstrated a significant decrease in activity on N0, suggesting limited duration of spontaneous pain elicited from the minor pain model.
In summary, activity was an effective and sensitive indicator for detecting pain using a paw incision pain model in C57BL/6 mice within the first 24 h postsurgery.
Additional studies using a major operative procedure should be performed to determine the effectiveness of activity as a pain detection indicator.

Related Results

Is a Fitbit a Diary? Self-Tracking and Autobiography
Is a Fitbit a Diary? Self-Tracking and Autobiography
Data becomes something of a mirror in which people see themselves reflected. (Sorapure 270)In a 2014 essay for The New Yorker, the humourist David Sedaris recounts an obsession spu...
Validity of the Fitbit activity tracker for measuring steps in community-dwelling older adults
Validity of the Fitbit activity tracker for measuring steps in community-dwelling older adults
Background Commercially available activity monitors, such as the Fitbit, may encourage physical activity. However, the accuracy of the Fitbit in older adults rema...
Abstract 173: Simple Guidance Improves Appropriate Telemetry Utilization
Abstract 173: Simple Guidance Improves Appropriate Telemetry Utilization
Introduction: Cardiac telemetry is an in-hospital monitoring tool intended for ischemia surveillance, monitor QT-interval prolongation, and detect arrhythmias. It is a ...
Electric Animal An Interview with Akira Mizuta Lippit & (untitled photographs)
Electric Animal An Interview with Akira Mizuta Lippit & (untitled photographs)
Dr. Akira Mizuta Lippit, author of Electric Animal: Toward a Rhetoric of Wildlife, explores, in the context of the development of cinema, how the concept of “the animal” has become...
Abstract 11292: Reducing Telemetry Utilization in Hospitalized Comfort Care Patients
Abstract 11292: Reducing Telemetry Utilization in Hospitalized Comfort Care Patients
Introduction: Telemetry overutilization increases costs and interventions that may result in patient harm, particularly at the end of life. ‘Comfort care’ (CC) patients...
Guideline‐based intervention to reduce telemetry rates in a large tertiary centre
Guideline‐based intervention to reduce telemetry rates in a large tertiary centre
AbstractBackgroundInappropriate cardiac telemetry use is associated with reduced patient flow and increased healthcare costs.AimTo evaluate the outcomes of guideline‐based applicat...

Back to Top