Javascript must be enabled to continue!
Audit Energi Listrik pada Bangunan Gedung SMKN 3 Kuningan
View through CrossRef
This research discusses Energy Audit at SMKN 3 Kuningan with the objective of evaluating the energy consumption intensity (IKE) in the buildings of SMKN 3 Kuningan. The methodology applied in this research involves measuring energy consumption through an energy audit and evaluating the measurement results based on IKE. The results obtained from data processing show that the total electrical energy consumption of the SMKN 3 Kuningan buildings is 112,613.11 kWh/year. Electrical energy consumption in air-conditioned rooms accounts for 80% of the total energy consumption, with electrical energy usage of 7,473 kWh/month, while non-air-conditioned rooms account for 20% of the total energy consumption, with an energy usage of 1,854 kWh/month. The calculated IKE value for air-conditioned rooms in SMKN 3 Kuningan buildings is 1.88 kWh/m²/month. Therefore, the air-conditioned rooms of SMKN 3 Kuningan buildings fall into the very efficient category as the IKE value is < 8.5 kWh/m²/month. The calculated IKE value for the non-air-conditioned rooms in SMKN 3 Kuningan buildings is 0.25 kWh/m²/month. Thus, the non-air-conditioned rooms of SMKN 3 Kuningan buildings fall into the very efficient category as the IKE value is < 3.4 kWh/m²/month. Both air-conditioned and non-air-conditioned rooms in the SMKN 3 Kuningan buildings meet the criteria for very efficient energy consumption intensity. Nevertheless, further research on energy saving opportunities can still be conducted to minimize electricity consumption costs at SMKN 3 Kuningan.
Title: Audit Energi Listrik pada Bangunan Gedung SMKN 3 Kuningan
Description:
This research discusses Energy Audit at SMKN 3 Kuningan with the objective of evaluating the energy consumption intensity (IKE) in the buildings of SMKN 3 Kuningan.
The methodology applied in this research involves measuring energy consumption through an energy audit and evaluating the measurement results based on IKE.
The results obtained from data processing show that the total electrical energy consumption of the SMKN 3 Kuningan buildings is 112,613.
11 kWh/year.
Electrical energy consumption in air-conditioned rooms accounts for 80% of the total energy consumption, with electrical energy usage of 7,473 kWh/month, while non-air-conditioned rooms account for 20% of the total energy consumption, with an energy usage of 1,854 kWh/month.
The calculated IKE value for air-conditioned rooms in SMKN 3 Kuningan buildings is 1.
88 kWh/m²/month.
Therefore, the air-conditioned rooms of SMKN 3 Kuningan buildings fall into the very efficient category as the IKE value is < 8.
5 kWh/m²/month.
The calculated IKE value for the non-air-conditioned rooms in SMKN 3 Kuningan buildings is 0.
25 kWh/m²/month.
Thus, the non-air-conditioned rooms of SMKN 3 Kuningan buildings fall into the very efficient category as the IKE value is < 3.
4 kWh/m²/month.
Both air-conditioned and non-air-conditioned rooms in the SMKN 3 Kuningan buildings meet the criteria for very efficient energy consumption intensity.
Nevertheless, further research on energy saving opportunities can still be conducted to minimize electricity consumption costs at SMKN 3 Kuningan.
Related Results
IDENTIFIKASI DAN KLASIFIKASI ASET INFRASTRUKTUR BANGUNAN GEDUNG DI UNIVERSITAS PALANGKA RAYA
IDENTIFIKASI DAN KLASIFIKASI ASET INFRASTRUKTUR BANGUNAN GEDUNG DI UNIVERSITAS PALANGKA RAYA
Aset infrastruktur bangunan gedung di lingkungan kampus berperan penting sebagai sarana penunjang kegiatan akademik maupun non akademik. Universitas Palangka Raya sebagai penyeleng...
PERBANDINGAN KELAYAKAN FINANSIAL GEDUNG GREEN BUILDING DAN NON- GREEN BUILDING MENGGUNAKAN METODE MONTE CARLO
PERBANDINGAN KELAYAKAN FINANSIAL GEDUNG GREEN BUILDING DAN NON- GREEN BUILDING MENGGUNAKAN METODE MONTE CARLO
Since 2011, Indonesia has been committed to reducing greenhouse gas emissions, one of which is by implementing green buildings in office buildings. The aim of implementing green bu...
Hubungan Kualitas Audit, Komite Audit, dan Dewan Pengawas Syariah terhadap Kinerja Bank Umum Syariah di Indonesia
Hubungan Kualitas Audit, Komite Audit, dan Dewan Pengawas Syariah terhadap Kinerja Bank Umum Syariah di Indonesia
ABSTRAK
Penelitian ini ditujukan untuk mengetahui hubungan kualitas audit, komite audit, dan Dewan Pengawas Syariah (DPS) terhadap kinerja Bank Umum Syariah di Indonesia pada tahun...
Paper K-9 Pelaporan Hasil Audit dan Tindak Lanjut Audit Internal
Paper K-9 Pelaporan Hasil Audit dan Tindak Lanjut Audit Internal
Pelaporan hasil audit merupakan komponen utama dalam komunikasi dari audit internal tentang hasil audit. Untuk mengkomunikasikan hasil audit diperlukan susunan laporan, dimana hasi...
Audit Energi pada Dua Produk Kaca Lembaran di sebuah Pabrik Kaca
Audit Energi pada Dua Produk Kaca Lembaran di sebuah Pabrik Kaca
Industri pembuatan kaca tersusun atas empat bagian primer, yaitu: kaca lembaran, kaca khusus, kaca fiber, dan kaca container. Pabrik X merupakan sebuah perusahaan besar penghasil k...
PELUANG PENGHEMATAN ENERGI PADA GEDUNG FAKULTAS TEKNIK UNIVERSITAS MUHAMMADIYAH PALEMBANG
PELUANG PENGHEMATAN ENERGI PADA GEDUNG FAKULTAS TEKNIK UNIVERSITAS MUHAMMADIYAH PALEMBANG
Gedung Fakultas Teknik Universitas Muhammadiyah Palembang merupakan salah satu sarana proses belajar mengajar yang terbagi menjadi dua gedung, yaitu gedung A dan gedung B. Menyedia...
Analisis Kehilangan Energi pada Berbagai Bentuk Bangunan Peralihan
Analisis Kehilangan Energi pada Berbagai Bentuk Bangunan Peralihan
AbstrakSaluran terbuka adalah aliran di saluran dimana air mengalir dengan permukan bebas. Pada saluran terbuka, umum ditemukan bangunan pelestarian. Khusunya pada jaringan irigasi...
Sistem Audit Intensitas Konsumsi Energi (IKE) Listrik Berbasis GUI Matlab
Sistem Audit Intensitas Konsumsi Energi (IKE) Listrik Berbasis GUI Matlab
Audit energi pada gedung atau bangunan sangatlah penting terutama penggunaan energi listrik, porsi pemakaian serta alokasi dana untuk penyediaan energi listrik merupakan salah satu...

