Javascript must be enabled to continue!
Comparison of Femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
View through CrossRef
Abstract
Objective: The purpose of this study was to compare the biomechanical and clinical results of two surgical methods for the treatment of vertical femoral neck fractures: Femoral neck system (FNS) and traditional three-cannulated cancellous screws (CCS).
Methods: First, we developed three different vertical femoral neck fracture models for the finite element analysis, with angles of 55°, 65°, and 75°, respectively. Two experimental groups were set up: the FNS group and the CCS group. Each fracture group was tested under axial loads of 2100 N to measure the femur's displacement, Von Mise stress (VMS), and its internal fixation components. Secondly, we retrospectively included the cases of vertical femoral neck fractures with FNS and CCS in our hospital from May 2019 to May 2021. In this study, we compared the duration of intraoperative fluoroscopy, operative time, hospital stay, fracture healing time, Hemoglobin loss, Harris score of hip joint function, and postoperative complications among patients undergoing hip joint replacement.
Results: In terms of finite element analysis, FNS has better anti-displacement stability than CCS at 55°and 65°, while FNS is greater than CCS in Von Mise stress. Clinically, we followed up on 87 patients for an average of 12 months. FNS was superior to traditional CCS in fracture healing time, operation time, fluoroscopy duration, fracture healing time, and Harris hip function score.
Conclusion: FNS is superior to traditional CCS in biomechanical and clinical aspects of treating vertical femoral neck fractures. There is potential for FNS to become a new treatment option for vertical femoral neck fractures.
Research Square Platform LLC
Title: Comparison of Femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
Description:
Abstract
Objective: The purpose of this study was to compare the biomechanical and clinical results of two surgical methods for the treatment of vertical femoral neck fractures: Femoral neck system (FNS) and traditional three-cannulated cancellous screws (CCS).
Methods: First, we developed three different vertical femoral neck fracture models for the finite element analysis, with angles of 55°, 65°, and 75°, respectively.
Two experimental groups were set up: the FNS group and the CCS group.
Each fracture group was tested under axial loads of 2100 N to measure the femur's displacement, Von Mise stress (VMS), and its internal fixation components.
Secondly, we retrospectively included the cases of vertical femoral neck fractures with FNS and CCS in our hospital from May 2019 to May 2021.
In this study, we compared the duration of intraoperative fluoroscopy, operative time, hospital stay, fracture healing time, Hemoglobin loss, Harris score of hip joint function, and postoperative complications among patients undergoing hip joint replacement.
Results: In terms of finite element analysis, FNS has better anti-displacement stability than CCS at 55°and 65°, while FNS is greater than CCS in Von Mise stress.
Clinically, we followed up on 87 patients for an average of 12 months.
FNS was superior to traditional CCS in fracture healing time, operation time, fluoroscopy duration, fracture healing time, and Harris hip function score.
Conclusion: FNS is superior to traditional CCS in biomechanical and clinical aspects of treating vertical femoral neck fractures.
There is potential for FNS to become a new treatment option for vertical femoral neck fractures.
Related Results
Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
Abstract
Background
Cannulated screws (CS) are one of the most widely used treatments for femoral neck fracture, however, associated with high rate ...
COMPARATIVE STUDY OF TENSION BAND WIRING, MODIFIED TENSION BAND WIRING AND FULLY THREADED CANNULATED CANCELLOUS SCREWS FOR FIXATION OF MEDIAL MALLEOLUS FRACTURES
COMPARATIVE STUDY OF TENSION BAND WIRING, MODIFIED TENSION BAND WIRING AND FULLY THREADED CANNULATED CANCELLOUS SCREWS FOR FIXATION OF MEDIAL MALLEOLUS FRACTURES
Objective: To compare the three most commonly used fixation techniques: “Tension band wiring, modified tension band wiring, and fully threaded cannulated cancellous screws for fixa...
=== PAPER RETRACTED === === PAPER RETRACTED === === PAPER RETRACTED === === PAPER RETRACTED === === PAPER RETRACTED === === PAPER RETRACTED === Knowledge of the Problem and Intention to Act on Student Environmentally Responsible Behavior
=== PAPER RETRACTED === === PAPER RETRACTED === === PAPER RETRACTED === === PAPER RETRACTED === === PAPER RETRACTED === === PAPER RETRACTED === Knowledge of the Problem and Intention to Act on Student Environmentally Responsible Behavior
<p><span lang="IN"><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">=== PAPER RETRACTED === </span></span></span...
FEMORAL NECK FRACTURES, EPIDEMIOLOGY, ANATOMICAL DESCRIPTION, MECHANISM OF ACTION, CLASSIFICATION, CLINICAL EVALUATION, IMAGING EVALUATION, TREATMENT AND COMPLICATIONS
FEMORAL NECK FRACTURES, EPIDEMIOLOGY, ANATOMICAL DESCRIPTION, MECHANISM OF ACTION, CLASSIFICATION, CLINICAL EVALUATION, IMAGING EVALUATION, TREATMENT AND COMPLICATIONS
Introduction: Femoral neck fractures (FNF) are frequent and devastating injuries in orthopedics and traumatology. It usually has several therapeutic options depending on the type o...
A comparative study of early functional outcomes in undisplaced neck of femur fracture treated with partially threaded and fully threaded cannulated screw fixation in patients above 60 years age
A comparative study of early functional outcomes in undisplaced neck of femur fracture treated with partially threaded and fully threaded cannulated screw fixation in patients above 60 years age
Objective: To compare the partially threaded versus fully threaded cannulated screw fixation methods in stable neck of femur fracture in terms of early functional outcomes in patie...
Study on the method of using absorbable screws combined with cannulated screws to treat calcaneal fractures using talar calcaneal distraction technique
Study on the method of using absorbable screws combined with cannulated screws to treat calcaneal fractures using talar calcaneal distraction technique
Abstract
Background: For intra-articular fractures with displaced posterior articular surface of calcaneus, more and more studies have shown that surgical treatment has bet...
Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries
Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries
OBJECTIVES:
To evaluate variables associated with loss of fixation of retrograde rami screws in the treatment of stress-positive minimally displaced lateral compression...
Safe range of femoral neck system insertion and the risk of perforation
Safe range of femoral neck system insertion and the risk of perforation
Abstract
Background
Internal fixation of the femoral neck carries a risk of perforation due to the presence of the isthmus of the femoral neck. At present, there are few s...


