Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparison of Femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis

View through CrossRef
Abstract Objective: The purpose of this study was to compare the biomechanical and clinical results of two surgical methods for the treatment of vertical femoral neck fractures: Femoral neck system (FNS) and traditional three-cannulated cancellous screws (CCS). Methods: First, we developed three different vertical femoral neck fracture models for the finite element analysis, with angles of 55°, 65°, and 75°, respectively. Two experimental groups were set up: the FNS group and the CCS group. Each fracture group was tested under axial loads of 2100 N to measure the femur's displacement, Von Mise stress (VMS), and its internal fixation components. Secondly, we retrospectively included the cases of vertical femoral neck fractures with FNS and CCS in our hospital from May 2019 to May 2021. In this study, we compared the duration of intraoperative fluoroscopy, operative time, hospital stay, fracture healing time, Hemoglobin loss, Harris score of hip joint function, and postoperative complications among patients undergoing hip joint replacement. Results: In terms of finite element analysis, FNS has better anti-displacement stability than CCS at 55°and 65°, while FNS is greater than CCS in Von Mise stress. Clinically, we followed up on 87 patients for an average of 12 months. FNS was superior to traditional CCS in fracture healing time, operation time, fluoroscopy duration, fracture healing time, and Harris hip function score. Conclusion: FNS is superior to traditional CCS in biomechanical and clinical aspects of treating vertical femoral neck fractures. There is potential for FNS to become a new treatment option for vertical femoral neck fractures.
Title: Comparison of Femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
Description:
Abstract Objective: The purpose of this study was to compare the biomechanical and clinical results of two surgical methods for the treatment of vertical femoral neck fractures: Femoral neck system (FNS) and traditional three-cannulated cancellous screws (CCS).
Methods: First, we developed three different vertical femoral neck fracture models for the finite element analysis, with angles of 55°, 65°, and 75°, respectively.
Two experimental groups were set up: the FNS group and the CCS group.
Each fracture group was tested under axial loads of 2100 N to measure the femur's displacement, Von Mise stress (VMS), and its internal fixation components.
Secondly, we retrospectively included the cases of vertical femoral neck fractures with FNS and CCS in our hospital from May 2019 to May 2021.
In this study, we compared the duration of intraoperative fluoroscopy, operative time, hospital stay, fracture healing time, Hemoglobin loss, Harris score of hip joint function, and postoperative complications among patients undergoing hip joint replacement.
Results: In terms of finite element analysis, FNS has better anti-displacement stability than CCS at 55°and 65°, while FNS is greater than CCS in Von Mise stress.
Clinically, we followed up on 87 patients for an average of 12 months.
FNS was superior to traditional CCS in fracture healing time, operation time, fluoroscopy duration, fracture healing time, and Harris hip function score.
Conclusion: FNS is superior to traditional CCS in biomechanical and clinical aspects of treating vertical femoral neck fractures.
There is potential for FNS to become a new treatment option for vertical femoral neck fractures.

Related Results

Safe range of femoral neck system insertion and the risk of perforation
Safe range of femoral neck system insertion and the risk of perforation
Abstract Background Internal fixation of the femoral neck carries a risk of perforation due to the presence of the isthmus of the femoral neck. At present, there are few s...

Back to Top