Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
View through CrossRef
Abstract
Background
Cannulated screws (CS) are one of the most widely used treatments for femoral neck fracture, however, associated with high rate of complications. In this study, we designed a new type of cannulated screws called degradable magnesium alloy bionic cannulated screws (DMBCS) and our aim was to compare the biomechanical properties of DMBCS, the traditionally used titanium alloy bionic cannulated screws (TBCS) and titanium alloy cannulated screws (TTCS).
Methods
A proximal femur model was established based on CT data of a lower extremity from a voluntary healthy man. Garden type III femoral neck fracture was constructed and fixed with DMBCS, TBCS, and TTCS, respectively. Biomechanical effect which three type of CS models have on femoral neck fracture was evaluated and compared using von Mises stress distribution and displacement.
Results
In the normal model, the maximum stress value of cortical bone and cancellous bone was 76.18 and 6.82 MPa, and the maximum displacement was 5.52 mm. Under 3 different fracture healing status, the stress peak value of the cortical bone and cancellous bone in the DMBCS fixation model was lower than that in the TTCS and TBCS fixation, while the maximum displacement of DMBCS fixation model was slightly higher than that of TTCS and TBCS fixation models. As the fracture heals, stress peak value of the screws and cortical bone of intact models are decreasing, while stress peak value of cancellous bone is increasing initially and then decreasing.
Conclusions
The DMBCS exhibits the superior biomechanical performance than TTCS and TBCS, whose fixation model is closest to the normal model in stress distribution. DMBCS is expected to reduce the rates of post-operative complications with traditional internal fixation and provide practical guidance for the structural design of CS for clinical applications.
Springer Science and Business Media LLC
Title: Titanium alloy cannulated screws and biodegradable magnesium alloy bionic cannulated screws for treatment of femoral neck fractures: a finite element analysis
Description:
Abstract
Background
Cannulated screws (CS) are one of the most widely used treatments for femoral neck fracture, however, associated with high rate of complications.
In this study, we designed a new type of cannulated screws called degradable magnesium alloy bionic cannulated screws (DMBCS) and our aim was to compare the biomechanical properties of DMBCS, the traditionally used titanium alloy bionic cannulated screws (TBCS) and titanium alloy cannulated screws (TTCS).
Methods
A proximal femur model was established based on CT data of a lower extremity from a voluntary healthy man.
Garden type III femoral neck fracture was constructed and fixed with DMBCS, TBCS, and TTCS, respectively.
Biomechanical effect which three type of CS models have on femoral neck fracture was evaluated and compared using von Mises stress distribution and displacement.
Results
In the normal model, the maximum stress value of cortical bone and cancellous bone was 76.
18 and 6.
82 MPa, and the maximum displacement was 5.
52 mm.
Under 3 different fracture healing status, the stress peak value of the cortical bone and cancellous bone in the DMBCS fixation model was lower than that in the TTCS and TBCS fixation, while the maximum displacement of DMBCS fixation model was slightly higher than that of TTCS and TBCS fixation models.
As the fracture heals, stress peak value of the screws and cortical bone of intact models are decreasing, while stress peak value of cancellous bone is increasing initially and then decreasing.
Conclusions
The DMBCS exhibits the superior biomechanical performance than TTCS and TBCS, whose fixation model is closest to the normal model in stress distribution.
DMBCS is expected to reduce the rates of post-operative complications with traditional internal fixation and provide practical guidance for the structural design of CS for clinical applications.
Related Results
Femoral Neck Fractures
Femoral Neck Fractures
(1) Repair of displaced femoral neck fractures has a high risk of treatment failure compared with most other fractures. These failures often require salvage surgery, including oste...
Enhanced Stability in an Unstable Femoral Neck Fracture Using the Femoral Neck System with Two Additional Cannulated Cancellous Screws: A Case Report
Enhanced Stability in an Unstable Femoral Neck Fracture Using the Femoral Neck System with Two Additional Cannulated Cancellous Screws: A Case Report
Introduction: Femoral neck fractures in young adults require urgent anatomical reduction and stable fixation to preserve the native femoral head and prevent complications, such as ...
FEMORAL NECK FRACTURES, EPIDEMIOLOGY, ANATOMICAL DESCRIPTION, MECHANISM OF ACTION, CLASSIFICATION, CLINICAL EVALUATION, IMAGING EVALUATION, TREATMENT AND COMPLICATIONS
FEMORAL NECK FRACTURES, EPIDEMIOLOGY, ANATOMICAL DESCRIPTION, MECHANISM OF ACTION, CLASSIFICATION, CLINICAL EVALUATION, IMAGING EVALUATION, TREATMENT AND COMPLICATIONS
Introduction: Femoral neck fractures (FNF) are frequent and devastating injuries in orthopedics and traumatology. It usually has several therapeutic options depending on the type o...
Comparison of Femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
Comparison of Femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
Abstract
Objective: The purpose of this study was to compare the biomechanical and clinical results of two surgical methods for the treatment of vertical femoral neck fract...
Effect of Teriparatide on Fracture Healing in Intertrochanteric Fractures Treated with Proximal Femoral Nailing: A Prospective Comparative Study
Effect of Teriparatide on Fracture Healing in Intertrochanteric Fractures Treated with Proximal Femoral Nailing: A Prospective Comparative Study
Introduction: Intertrochanteric fractures are common in the elderly and are associated with significant morbidity and delayed functional recovery. Proximal femoral nailing (PFN) is...
Dynamic compression locking system versus multiple cannulated compression screw for the treatment of femoral neck fractures: a comparative study
Dynamic compression locking system versus multiple cannulated compression screw for the treatment of femoral neck fractures: a comparative study
Abstract
Background
Femoral neck fractures are one of the problems in orthopedic treatment. The prognosis is uncertain. Currently, there is no one internal fixation for th...
Dynamic compression locking system versus multiple cannulated compression screw for the treatment of femoral neck fractures: a comparative study
Dynamic compression locking system versus multiple cannulated compression screw for the treatment of femoral neck fractures: a comparative study
Abstract
Background: Femoral neck fractures are one of the problems in orthopedic treatment. The prognosis is uncertain. Currently, there is no one internal fixation for th...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...