Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Automatic Monitoring and Control System of Distribution Network Transformer Energy Consumption Based on Single-Chip Microcomputer

View through CrossRef
Distribution network transformers are widely used in power systems. Aiming at the problem that high energy consumption is easy to lead to energy waste, an automatic detection and control system of energy consumption of distribution network transformer based on single-chip microcomputer technology is proposed. The control center of the system design is a single-chip microcomputer, which calculates the transformer load through the multi-function meter, and sets the corresponding gear adjustment threshold to adjust the capacity of the transformer, so as to reduce losses and save energy. After case verification, this method can greatly improve the energy-saving effect of distribution network transformers, and at the same time operate stably and reliably.
Auricle Global Society of Education and Research
Title: Automatic Monitoring and Control System of Distribution Network Transformer Energy Consumption Based on Single-Chip Microcomputer
Description:
Distribution network transformers are widely used in power systems.
Aiming at the problem that high energy consumption is easy to lead to energy waste, an automatic detection and control system of energy consumption of distribution network transformer based on single-chip microcomputer technology is proposed.
The control center of the system design is a single-chip microcomputer, which calculates the transformer load through the multi-function meter, and sets the corresponding gear adjustment threshold to adjust the capacity of the transformer, so as to reduce losses and save energy.
After case verification, this method can greatly improve the energy-saving effect of distribution network transformers, and at the same time operate stably and reliably.

Related Results

Research on Analysis and Classification of Vulnerability of Electromagnetic Pulse with a STM32 Single-Chip Microcomputer
Research on Analysis and Classification of Vulnerability of Electromagnetic Pulse with a STM32 Single-Chip Microcomputer
With the continuous development of information technology, the performance of the entire traditional electrical system is gradually optimized. Nowadays, the single-chip technology ...
Automatic Load Sharing of Transformer
Automatic Load Sharing of Transformer
Transformer plays a major role in the power system. It works 24 hours a day and provides power to the load. The transformer is excessive full, its windings are overheated which lea...
Simulation modeling study on short circuit ability of distribution transformer
Simulation modeling study on short circuit ability of distribution transformer
Abstract Under short circuit condition, the oil immersed distribution transformer will endure combined electro-thermal stress, eventually lead to the mechanical dama...
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
LIFE CYCLE OF TRANSFORMER 110/X KV AND ITS VALUE
In a deregulated environment, power companies are in the constant process of reducing the costs of operating power facilities, with the aim of optimally improving the quality of de...
The methodical issues of industrial energy monitoring systems implementation
The methodical issues of industrial energy monitoring systems implementation
Statistics show that energy is one of the highest operating costs in a manufacturing enterprise. So, improving energy efficiency can lead to a significant increase in profits and r...
Materialism and Environmental Knowledge as a Mediator for Relationships between Religiosity and Ethical Consumption
Materialism and Environmental Knowledge as a Mediator for Relationships between Religiosity and Ethical Consumption
ABSTRACTOn a global and regional scale, Indonesia has one of the least environmentally sustainable economies in the Asia-Pacific region. Consumption is one of the key factors contr...
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
ANALISIS PENGARUH MASA OPERASIONAL TERHADAP PENURUNAN KAPASITAS TRANSFORMATOR DISTRIBUSI DI PT PLN (PERSERO)
One cause the interruption of transformer is loading that exceeds the capabilities of the transformer. The state of continuous overload will affect the age of the transformer and r...
Energy-saving design and implementation in metro weak current systems: a case study of the Kunming metro system
Energy-saving design and implementation in metro weak current systems: a case study of the Kunming metro system
AbstractWith the accelerated urbanization in China, along with the growing scale of the metro transportation network, the energy consumption of metro systems continues to increase....

Back to Top