Magnetic Remanence of Stainless Steel and Titanium Alloy Orthopaedic Implants

View through CrossRef
Stainless steel and titanium alloys are common materials for orthopaedic implants. However there is a lack of information and studies on magnetic remanence of  implants used in clinical practice. The aims of this study are to investigate the composition and the presence of magnetic remanence for these two orthopaedic implant materials. These two factors may cause implant instability and heat problems as well as degradation of the images quality if the patients undergo magnetic resonance imaging (MRI) examination. The magnetic hysteresis loop and remanence status of stainless steel and titanium alloy orthopaedic implants were investigated with a vibrating sample magnetometer (VSM). Both samples of stainless steel and titanium alloy had been exposed to external magnetic fields up to 1 T (10000 G) and 1.4 T (14000 G), respectively. The compositions of these two orthopaedic implant materials were studied using a scanning electron microscope with energy dispersive X-ray analysis (SEM-EDX). The results of the study demonstrated that ferrous and nickel compositions in stainless steel alloy orthopaedic implants contributed to the residual magnetism, as shown in the hysteresis loop. The titanium alloy orthopaedic implant sample does not contain any ferromagnetic elements. After exposure to a magnetic field, the stainless steel values of retentivity, coercivity and magnetisation are significantly higher compared to those of the titanium alloy. The stainless steel orthopaedic implant sample demonstrates a typical hysteresis loop that suggests the existence of magnetic remanence. In contrast, the titanium alloy orthopaedic implant sample showed no significant remanence phenomenon. By considering the existence of magnetic remanence in the implant is important as potential effect on the MRI image quality.
Title: Magnetic Remanence of Stainless Steel and Titanium Alloy Orthopaedic Implants
Description:
Stainless steel and titanium alloys are common materials for orthopaedic implants.
However there is a lack of information and studies on magnetic remanence of  implants used in clinical practice.
The aims of this study are to investigate the composition and the presence of magnetic remanence for these two orthopaedic implant materials.
These two factors may cause implant instability and heat problems as well as degradation of the images quality if the patients undergo magnetic resonance imaging (MRI) examination.
The magnetic hysteresis loop and remanence status of stainless steel and titanium alloy orthopaedic implants were investigated with a vibrating sample magnetometer (VSM).
Both samples of stainless steel and titanium alloy had been exposed to external magnetic fields up to 1 T (10000 G) and 1.
4 T (14000 G), respectively.
The compositions of these two orthopaedic implant materials were studied using a scanning electron microscope with energy dispersive X-ray analysis (SEM-EDX).
The results of the study demonstrated that ferrous and nickel compositions in stainless steel alloy orthopaedic implants contributed to the residual magnetism, as shown in the hysteresis loop.
The titanium alloy orthopaedic implant sample does not contain any ferromagnetic elements.
After exposure to a magnetic field, the stainless steel values of retentivity, coercivity and magnetisation are significantly higher compared to those of the titanium alloy.
The stainless steel orthopaedic implant sample demonstrates a typical hysteresis loop that suggests the existence of magnetic remanence.
In contrast, the titanium alloy orthopaedic implant sample showed no significant remanence phenomenon.
By considering the existence of magnetic remanence in the implant is important as potential effect on the MRI image quality.

Related Results

Clad Steel Pipe for Corrosive Gas Transportation
Clad Steel Pipe for Corrosive Gas Transportation
ABSTRACT This paper describes the applicability and reliability Of clad steel pipe and its welds in sour gas environments in comparison with those of 22%Cr-5.5%Ni...
Assessment of cranial reconstruction utilizing various implant materials: finite element study
Assessment of cranial reconstruction utilizing various implant materials: finite element study
AbstractThe human head can sometimes experience impact loads that result in skull fractures or other injuries, leading to the need for a craniectomy. Cranioplasty is a procedure th...
Dr DD Tanna – Story of a Legend
Dr DD Tanna – Story of a Legend
This interview was conducted at the famous Lotus Clinic at Mumbai. Interview of Dr DD Tanna (DDT) was personally conducted by our Editor Dr Ashok Shyam (AK). It was an interesting ...
15th World Conference on Titanium Chapter 2: Aerospace Applications
15th World Conference on Titanium Chapter 2: Aerospace Applications
RECENT ADVANCES IN TITANIUM ALLOY EXTRUSIONS FOR AEROSPACE APPLICATIONS TECHNOLOGY CAPABILITY STUDY OF LASER POWDER BED FUSION TO PRODUCE LARGE CRITICAL AEROSPACE S...
Comparative Cost-Effectiveness of Cranioplasty Implants
Comparative Cost-Effectiveness of Cranioplasty Implants
Purpose: The aim of this study was to compare operative duration and total hospital costs incurred for patients undergoing elective cranioplasty with a variety ...
Clinical outcomes of zirconia implants: a systematic review and meta-analysis
Clinical outcomes of zirconia implants: a systematic review and meta-analysis
Abstract Purpose To assess the clinical outcomes of zirconia dental implants based on an updated systematic literature review. ...