Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Osteocyte culture in microfluidic devices

View through CrossRef
This paper presents a microfluidic device (poly-dimethylsiloxane micro channels bonded with glass slides) enabling culture of MLO-Y4 osteocyte like cells. In this study, on-chip collagen coating, cell seeding and culture, as well as staining were demonstrated in a tubing-free manner where gravity was used as the driving force for liquid transportation. MLO-Y4 cells were cultured in microfluidic channels with and without collagen coating where cellular images in a time sequence were taken and analyzed, confirming the positive effect of collagen coating on phenotype maintaining of MLO-Y4 cells. The proliferating cell nuclear antigen based proliferation assay was used to study cellular proliferation, revealing a higher proliferation rate of MLO-Y4 cells seeded in microfluidic channels without collagen coating compared to the substrates coated with collagen. Furthermore, the effects of channel dimensions (variations in width and height) on the viability of MLO-Y4 cells were explored based on the Calcein-AM and propidium iodide based live/dead assay and the Hoechst 33258 based apoptosis assay, locating the correlation between the decrease in channel width or height and the decrease in cell viability. As a platform technology, this microfluidic device may function as a new cell culture model enabling studies of osteocytes.
Title: Osteocyte culture in microfluidic devices
Description:
This paper presents a microfluidic device (poly-dimethylsiloxane micro channels bonded with glass slides) enabling culture of MLO-Y4 osteocyte like cells.
In this study, on-chip collagen coating, cell seeding and culture, as well as staining were demonstrated in a tubing-free manner where gravity was used as the driving force for liquid transportation.
MLO-Y4 cells were cultured in microfluidic channels with and without collagen coating where cellular images in a time sequence were taken and analyzed, confirming the positive effect of collagen coating on phenotype maintaining of MLO-Y4 cells.
The proliferating cell nuclear antigen based proliferation assay was used to study cellular proliferation, revealing a higher proliferation rate of MLO-Y4 cells seeded in microfluidic channels without collagen coating compared to the substrates coated with collagen.
Furthermore, the effects of channel dimensions (variations in width and height) on the viability of MLO-Y4 cells were explored based on the Calcein-AM and propidium iodide based live/dead assay and the Hoechst 33258 based apoptosis assay, locating the correlation between the decrease in channel width or height and the decrease in cell viability.
As a platform technology, this microfluidic device may function as a new cell culture model enabling studies of osteocytes.

Related Results

Morphometric Changes of Osteocyte Lacunar in Diabetic Pig Mandibular Cancellous Bone
Morphometric Changes of Osteocyte Lacunar in Diabetic Pig Mandibular Cancellous Bone
Osteocytes play an important role in bone metabolism. The interactions of osteocytes with the surrounding microenvironment can alter cellular and lacunar morphological changes. How...
Slip-driven microfluidic devices for nucleic acid analysis
Slip-driven microfluidic devices for nucleic acid analysis
Slip-driven microfluidic devices can manipulate fluid by the relative movement of microfluidic plates that are in close contact. Since the demonstration of the first SlipChip devic...
Flow Cytometry, Beads, and Microchannels
Flow Cytometry, Beads, and Microchannels
Microfluidic devices generally consume microliter to submicroliter volumes of sample and are thus well suited for use when the required reagents are scarce or expensive. Because mi...
Double-Sided Tape in Microfluidics: A Cost-Effective Method in Device Fabrication
Double-Sided Tape in Microfluidics: A Cost-Effective Method in Device Fabrication
The demand for easy-to-use, affordable, accessible, and reliable technology is increasing in biological, chemical, and medical research. Microfluidic devices have the potential to ...
Utilizing microfluidic chips for rapid, on-site detection of antimicrobial resistance in infectious pathogens
Utilizing microfluidic chips for rapid, on-site detection of antimicrobial resistance in infectious pathogens
The rise of antimicrobial resistance (AMR) in infectious pathogens presents a significant global health challenge, necessitating rapid and accurate diagnostic tools for timely inte...
Application of Microfluidic Devices for Automated Two‐Step Radiolabeling of Antibodies
Application of Microfluidic Devices for Automated Two‐Step Radiolabeling of Antibodies
ABSTRACTRadioimmunoconjugates (RICs) composed of tumor‐targeting monoclonal antibodies and radionuclides have been developed for diagnostic and therapeutic application. A new radio...
Printed Capillary Microfluidic Devices and Their Application in Biosensing
Printed Capillary Microfluidic Devices and Their Application in Biosensing
Microfluidic devices with a free-standing structure were printed directly on polymer films using the functional materials that form interconnected pores. The printed devices can tr...

Back to Top