Javascript must be enabled to continue!
Flow Cytometry, Beads, and Microchannels
View through CrossRef
Microfluidic devices generally consume microliter to submicroliter volumes of sample and are thus well suited for use when the required reagents are scarce or expensive. Because microfluidic devices operate in a regime in which small Reynolds numbers govern the delivery of fluid samples, reagent mixing and subsequent reactivity has been a severe limiting factor in their applicability. The inclusion of packed beads in the microfluidic device repertoire has several advantages: molecular assemblies for the assay are created outside the channel on beads and characterized with flow cytometry, uniform populations of beads may be assured through rapid cytometric sorting, beads present a larger surface area for the display of receptors than flat surfaces, rapid mixing in the microcolumn is achieved because the distance that must be covered by diffusion is limited to the (≤1-μm) interstitial space between the closely packed receptorbearing beads, and analytes are captured in a flow-through format and, as such, each bead can act as a local concentrator of analytes. Progress in the combined use of beads and microfluidic devices has been limited by the ability to pack beads at specific sections of microfluidic devices. A subsequent challenge associated with the packed microcolumns of beads is the substantial pressure drop that affects the fluid flow velocity. However, some of these challenges have been overcome in the design of simple model systems that have potential applications in DNA analysis, chromatography, and immunoassays. It is the intent of this chapter to examine the recent emergence of small-volume heterogeneous immunoassays, using beads trapped in microchannels, while excluding other closely related applications such as capillary electrophoresis and flow injection–based approaches. Of necessity, the authors’ interests and availability of information pertinent to the specific discussions presented below impose additional restrictions. To date, there are only a handful of applications that combine packed beads and microfluidic devices, and even fewer that make the overt connection between flow cytometry–based assays and beads. Harrison and coworkers have provided one of the earliest conceptual demonstrations of the capability to incorporate packed beads in microfluidic devices for analytical purposes.
Title: Flow Cytometry, Beads, and Microchannels
Description:
Microfluidic devices generally consume microliter to submicroliter volumes of sample and are thus well suited for use when the required reagents are scarce or expensive.
Because microfluidic devices operate in a regime in which small Reynolds numbers govern the delivery of fluid samples, reagent mixing and subsequent reactivity has been a severe limiting factor in their applicability.
The inclusion of packed beads in the microfluidic device repertoire has several advantages: molecular assemblies for the assay are created outside the channel on beads and characterized with flow cytometry, uniform populations of beads may be assured through rapid cytometric sorting, beads present a larger surface area for the display of receptors than flat surfaces, rapid mixing in the microcolumn is achieved because the distance that must be covered by diffusion is limited to the (≤1-μm) interstitial space between the closely packed receptorbearing beads, and analytes are captured in a flow-through format and, as such, each bead can act as a local concentrator of analytes.
Progress in the combined use of beads and microfluidic devices has been limited by the ability to pack beads at specific sections of microfluidic devices.
A subsequent challenge associated with the packed microcolumns of beads is the substantial pressure drop that affects the fluid flow velocity.
However, some of these challenges have been overcome in the design of simple model systems that have potential applications in DNA analysis, chromatography, and immunoassays.
It is the intent of this chapter to examine the recent emergence of small-volume heterogeneous immunoassays, using beads trapped in microchannels, while excluding other closely related applications such as capillary electrophoresis and flow injection–based approaches.
Of necessity, the authors’ interests and availability of information pertinent to the specific discussions presented below impose additional restrictions.
To date, there are only a handful of applications that combine packed beads and microfluidic devices, and even fewer that make the overt connection between flow cytometry–based assays and beads.
Harrison and coworkers have provided one of the earliest conceptual demonstrations of the capability to incorporate packed beads in microfluidic devices for analytical purposes.
Related Results
Procedure for Latex beads coating with glycolipids v1
Procedure for Latex beads coating with glycolipids v1
Goal: This document aims to standardize the protocol for latex beads coating with the Mycobacterium leprae phenolic glycolipid “PGL I”. Beads-PGL I coating is used, for example, fo...
Glass Beads of 7th to 17th-Century CE Sub-Saharan Africa
Glass Beads of 7th to 17th-Century CE Sub-Saharan Africa
The value of glass beads to archaeologists has increased dramatically in the 21st century thanks to the development and improvements of methods to analyze the chemical composition ...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Dynamics and wall collision of inertial particles in a solid–liquid turbulent channel flow
Dynamics and wall collision of inertial particles in a solid–liquid turbulent channel flow
The dynamics and wall collision of inertial particles were investigated in non-isotropic turbulence of a horizontal liquid channel flow. The inertial particles were $125~\unicode[S...
Encapsulation of pendimethalin by ate coalginmposite beads
Encapsulation of pendimethalin by ate coalginmposite beads
In this research, the formulations for chitosan and chitosan-alginate beads containing pendimethalin were developed and explored for their control release ability. The entrapment o...
Numerical Investigation of Flow Boiling in Interconnected Microchannels at Varying Mass Fluxes
Numerical Investigation of Flow Boiling in Interconnected Microchannels at Varying Mass Fluxes
Interconnected microchannels (IMCs) in flow boiling have the advantages of optimized heat transfer performance, energy savings and high efficiency, compact size, and strong customi...
Milling Microchannels in Monel 400 Alloy by Wire EDM: An Experimental Analysis
Milling Microchannels in Monel 400 Alloy by Wire EDM: An Experimental Analysis
This paper presents the results of an investigation on the capacity of wire electrical discharge machining (WEDM) to produce microchannels in the Nickel-based alloy, Monel 400. The...
Numerical Thermohydraulic Analysis of Flow Boiling in Geometrical-Modified Microchannels
Numerical Thermohydraulic Analysis of Flow Boiling in Geometrical-Modified Microchannels
One of the major issues of flow boiling in microchannels is ensuring adequatemanagement of thermohydraulic instabilities which severely impact the system’s efficiency ...

