Javascript must be enabled to continue!
Minimum Required Distance for Clinically Significant Measurement of Habitual Gait Speed
View through CrossRef
Abstract
Background: Gait speed indicates morbidity and life expectancy in older adults, but the minimum walking distance for measurement remains unclear. This study aimed to determine the minimum distance required to measure clinically reliable gait speed using a smartphone camera and pose estimation, and whether the distance is influenced by subject characteristics or measurement methods.
Methods: Twenty-four healthy volunteers (> 65 years old) performed a video-recorded 10-m gait test, excluding acceleration and deceleration. Fourteen body points were derived using a pose-estimation algorithm. Speed was calculated based on the center of mass or a leading foot which simulates a condition with a walkway sensor and validated against manual measurements. Multiple videos of gait over varying distances were obtained by cropping video frames at 0.1-meter intervals. Variance in gait speed over specific distances was calculated using ANOVA. “Minimum required distance” was defined as the shortest distance where the confidence interval of gait speed did not exceed the minimal clinically important difference (0.1 m/sec). We also investigated which clinical, anthropometric, or epidemiological variables might influence it by assessing their association with gait speed variance using mean squared error from linear regression.
Results: Gait speed measured by pose estimation (1.55 ± 0.18 m/s) highly corresponded with manual measurement (1.56 ± 0.14 m/s) (r = 0.866, p < 0.001). “Minimum required distance” was 2.1 meter when gait speed was calculated with the center of mass with 95% confidence interval while “minimun required distance” based on a leading foot was 4.7 meter with 90% confidence interval. Gait speed itself and muscle strength was positively correlated with gait speed variance (r = 0.250, p = 0.036 for gait speed; r = 0.312, p = 0.008 for knee extensor strength; r = 0.230, p = 0.053 for grip strength) while other epidemiologic or clinical parameters including age and physical performance scales did not.
Conclusions: Clinically reliable measurement of gait speed could be achieved over 2.1 meter using a smartphone and pose estimation inducing the center of mass with 95% confidence level. The weaker the muscle strength or the slower the gait speed, the shorter the distance might be required.
Springer Science and Business Media LLC
Title: Minimum Required Distance for Clinically Significant Measurement of Habitual Gait Speed
Description:
Abstract
Background: Gait speed indicates morbidity and life expectancy in older adults, but the minimum walking distance for measurement remains unclear.
This study aimed to determine the minimum distance required to measure clinically reliable gait speed using a smartphone camera and pose estimation, and whether the distance is influenced by subject characteristics or measurement methods.
Methods: Twenty-four healthy volunteers (> 65 years old) performed a video-recorded 10-m gait test, excluding acceleration and deceleration.
Fourteen body points were derived using a pose-estimation algorithm.
Speed was calculated based on the center of mass or a leading foot which simulates a condition with a walkway sensor and validated against manual measurements.
Multiple videos of gait over varying distances were obtained by cropping video frames at 0.
1-meter intervals.
Variance in gait speed over specific distances was calculated using ANOVA.
“Minimum required distance” was defined as the shortest distance where the confidence interval of gait speed did not exceed the minimal clinically important difference (0.
1 m/sec).
We also investigated which clinical, anthropometric, or epidemiological variables might influence it by assessing their association with gait speed variance using mean squared error from linear regression.
Results: Gait speed measured by pose estimation (1.
55 ± 0.
18 m/s) highly corresponded with manual measurement (1.
56 ± 0.
14 m/s) (r = 0.
866, p < 0.
001).
“Minimum required distance” was 2.
1 meter when gait speed was calculated with the center of mass with 95% confidence interval while “minimun required distance” based on a leading foot was 4.
7 meter with 90% confidence interval.
Gait speed itself and muscle strength was positively correlated with gait speed variance (r = 0.
250, p = 0.
036 for gait speed; r = 0.
312, p = 0.
008 for knee extensor strength; r = 0.
230, p = 0.
053 for grip strength) while other epidemiologic or clinical parameters including age and physical performance scales did not.
Conclusions: Clinically reliable measurement of gait speed could be achieved over 2.
1 meter using a smartphone and pose estimation inducing the center of mass with 95% confidence level.
The weaker the muscle strength or the slower the gait speed, the shorter the distance might be required.
Related Results
Minimum required distance for clinically significant measurement of habitual gait speed
Minimum required distance for clinically significant measurement of habitual gait speed
Abstract
Background
Gait speed indicates morbidity and life expectancy in older adults, but the minimum walking distance ...
Making Sense of Sensor Data
Making Sense of Sensor Data
Every year, approximately 12.2 million people worldwide experience a stroke, placing a significant burden on individuals, families, and healthcare systems. Despite rehabilitation, ...
MO616GAIT SPEED AND BODY COMPOSITION IN HAEMODIALYSIS PATIENTS
MO616GAIT SPEED AND BODY COMPOSITION IN HAEMODIALYSIS PATIENTS
Abstract
Background and Aims
Gait speed is a predictor of disability, mobility limitation and mortality. Buchner et al. the firs...
Gait assessments in patients with early Parkinson's disease
Gait assessments in patients with early Parkinson's disease
Introduction : Gait disturbances are affected in all stages of PD. At the early stages of the disease, gait disturbances can be present but in most patients, it does not cause sign...
Validity of self-reporting of gait alteration after tap test among patients with idiopathic normal pressure hydrocephalus
Validity of self-reporting of gait alteration after tap test among patients with idiopathic normal pressure hydrocephalus
PurposeThe study aimed to examine the validity of self-reporting as an additional method to indicate gait alteration among patients with idiopathic normal pressure hydrocephalus. T...
Gait Variability Can Predict the Risk of Cognitive Decline in Cognitively Normal Older People
Gait Variability Can Predict the Risk of Cognitive Decline in Cognitively Normal Older People
<b><i>Background:</i></b> The aim of this study was to investigate the association of gait speed and gait variability, an index of how much gait parameters,...
Clinical improvements in temporospatial gait variables after a spinal tap test in individuals with idiopathic normal pressure hydrocephalus
Clinical improvements in temporospatial gait variables after a spinal tap test in individuals with idiopathic normal pressure hydrocephalus
AbstractIdiopathic Normal Pressure Hydrocephalus (iNPH) is a neurological condition that often presents gait disturbance in the early stages of the disease and affects other motor ...
Gait Training Techniques in Children
Gait Training Techniques in Children
The development of gait is a fundamental milestone in childhood that signifies the onset of functional independence, social engagement, and cognitive exploration. The book “Gait Tr...

