Minimum required distance for clinically significant measurement of habitual gait speed

View through CrossRef
Abstract Background Gait speed indicates morbidity and life expectancy in older adults, but the minimum walking distance for measurement remains unclear. This study aimed to determine the minimum distance required to measure clinically reliable gait speed using a smartphone camera and pose estimation, and whether the distance is influenced by subject characteristics or measurement methods. Methods Twenty-four healthy volunteers (≥ 65 years old) performed a video-recorded 10-m gait test, including acceleration and deceleration. Fourteen body points were derived using a pose-estimation algorithm. Speed was calculated based on the center of mass or a leading foot which simulates a condition with a walkway sensor and validated against manual measurements. Multiple videos of gait over varying distances were obtained by cropping video frames at 0.1-m intervals. Variance in gait speed over specific distances was calculated using ANOVA. “Minimum required distance” was defined as the shortest distance where the confidence interval of gait speed did not exceed the minimal clinically important difference (0.1 m/sec). We also investigated which clinical, anthropometric, or epidemiological variables might influence it by assessing their association with gait speed variance using mean squared error from linear regression. Results Gait speed measured by pose estimation (1.55 ± 0.18 m/s) showed a high level of agreement with manual measurement (1.56 ± 0.14 m/s), with an intraclass correlation coefficient of 0.889 (95% CI: 0.822–0.931). “Minimum required distance” was 2.1 m when gait speed was calculated with the center of mass with 95% confidence interval while “minimun required distance” based on a leading foot was 4.7 m with 90% confidence interval. Gait speed itself and muscle strength were positively correlated with gait speed variance ( r  = 0.250, p  = 0.036 for gait speed; r  = 0.312, p  = 0.008 for knee extension strength; r  = 0.230, p  = 0.053 for grip strength), whereas other epidemiologic or clinical parameters, and physical performance scales, were not. Conclusions Clinically reliable measurement of gait speed could be achieved over 2.1 m using a smartphone and pose estimation inducing the center of mass with 95% confidence interval. The weaker the muscle strength or the slower the gait speed, the shorter the distance might be required.
Title: Minimum required distance for clinically significant measurement of habitual gait speed
Description:
Abstract Background Gait speed indicates morbidity and life expectancy in older adults, but the minimum walking distance for measurement remains unclear.
This study aimed to determine the minimum distance required to measure clinically reliable gait speed using a smartphone camera and pose estimation, and whether the distance is influenced by subject characteristics or measurement methods.
Methods Twenty-four healthy volunteers (≥ 65 years old) performed a video-recorded 10-m gait test, including acceleration and deceleration.
Fourteen body points were derived using a pose-estimation algorithm.
Speed was calculated based on the center of mass or a leading foot which simulates a condition with a walkway sensor and validated against manual measurements.
Multiple videos of gait over varying distances were obtained by cropping video frames at 0.
1-m intervals.
Variance in gait speed over specific distances was calculated using ANOVA.
“Minimum required distance” was defined as the shortest distance where the confidence interval of gait speed did not exceed the minimal clinically important difference (0.
1 m/sec).
We also investigated which clinical, anthropometric, or epidemiological variables might influence it by assessing their association with gait speed variance using mean squared error from linear regression.
Results Gait speed measured by pose estimation (1.
55 ± 0.
18 m/s) showed a high level of agreement with manual measurement (1.
56 ± 0.
14 m/s), with an intraclass correlation coefficient of 0.
889 (95% CI: 0.
822–0.
931).
“Minimum required distance” was 2.
1 m when gait speed was calculated with the center of mass with 95% confidence interval while “minimun required distance” based on a leading foot was 4.
7 m with 90% confidence interval.
Gait speed itself and muscle strength were positively correlated with gait speed variance ( r  = 0.
250, p  = 0.
036 for gait speed; r  = 0.
312, p  = 0.
008 for knee extension strength; r  = 0.
230, p  = 0.
053 for grip strength), whereas other epidemiologic or clinical parameters, and physical performance scales, were not.
Conclusions Clinically reliable measurement of gait speed could be achieved over 2.
1 m using a smartphone and pose estimation inducing the center of mass with 95% confidence interval.
The weaker the muscle strength or the slower the gait speed, the shorter the distance might be required.

Related Results

Minimum Required Distance for Clinically Significant Measurement of Habitual Gait Speed
Minimum Required Distance for Clinically Significant Measurement of Habitual Gait Speed
Abstract Background: Gait speed indicates morbidity and life expectancy in older adults, but the minimum walking distance for measurement remains unclear. This study aimed ...
Gait assessments in patients with early Parkinson's disease
Gait assessments in patients with early Parkinson's disease
Introduction : Gait disturbances are affected in all stages of PD. At the early stages of the disease, gait disturbances can be present but in most patients, it does not cause sign...
Gait Variability Can Predict the Risk of Cognitive Decline in Cognitively Normal Older People
Gait Variability Can Predict the Risk of Cognitive Decline in Cognitively Normal Older People
<b><i>Background:</i></b> The aim of this study was to investigate the association of gait speed and gait variability, an index of how much gait parameters,...
Gait Training Techniques in Children
Gait Training Techniques in Children
The development of gait is a fundamental milestone in childhood that signifies the onset of functional independence, social engagement, and cognitive exploration. The book “Gait Tr...
Research on obstacle climbing gait structure design and gait control of hexapod wall climbing robot based on STM32F103 core controller
Research on obstacle climbing gait structure design and gait control of hexapod wall climbing robot based on STM32F103 core controller
The hexapod wall climbing robots have the advantages of traversing complex wall surfaces. To traverse complex environments autonomously, it must possess the capability to select ga...
The Habitual Pastin Amele, Papua New Guinea
The Habitual Pastin Amele, Papua New Guinea
This study attempts to clarify the tense systems in Madang Province, Papua New Guinea; particularly, the past tense and habitual past forms in the sample three languages in the are...
Quantitative parameters of the kinetics and kinematics of the iatrogenic crouch gait pattern
Quantitative parameters of the kinetics and kinematics of the iatrogenic crouch gait pattern
The pattern of pathological crouch gait in patients with spastic paralysis is characteristic of diplegic forms and in natural development manifests itself usually after the age of ...
Data-driven AD-Related Pathology Phenotypes Differentiate Slow Gait and Memory Impairment in Mild Cognitive Impairment
Data-driven AD-Related Pathology Phenotypes Differentiate Slow Gait and Memory Impairment in Mild Cognitive Impairment
Gait impairment is increasingly recognized as a motor marker associated with Alzheimer’s disease (AD) pathology. However, it remains unclear how distinct AD pathology phenotypes re...

Back to Top