Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Implementation of mobile EEG for resting-state and visual evoked potentials in young children in rural Ethiopia

View through CrossRef
Children living in low- and middle-income countries (LMIC) are at disproportionately higher risk of neurodevelopmental delays due to exposure to adverse biological and environmental hazards. In infancy, global developmental assessments, such as the Bayley Scales, are insensitive, do not strongly correlate with later cognitive outcomes, and require adaptation for different populations and cultural contexts. Electroencephalography (EEG) objectively measures electrical brain activity and may provide early neural markers predictive of long-term cognitive outcomes. The visual evoked potential (VEP) interrogates the efficiency of visual cortical processing and reflects neural processing speed. Mobile EEG enables the assessment of neural processing in settings where such technologies were historically inaccessible. This paper describes the experiences and lessons learned from implementing mobile EEG and VEP in rural Amhara, Ethiopia as part of the Longitudinal Infant Growth and Development (LIDG) study (NCT06296238). We describe adaptations and strategies to address and optimize data capture (e.g., dry electrode tips to improve scalp contact, tailored protocols, and adequate equipment specifications), environmental challenges (e.g., space constraints, lack of water supply, power outage) and cultural factors (e.g., hair type) unique to the study setting and population. Our formative research underscored the importance of creating awareness among community members (e.g., mothers, fathers, and religious leaders) and local clinicians to improve community engagement and buy-in. Culturally sensitive child behavior management techniques were also critical to ensure EEG completion and high data quality. With community sensitization, we had high consent rates for EEG/VEP (>90%). We completed EEG recordings within an average ± standard deviation of 20 ± 11 minutes. After data processing, approximately 90% and 70% of participants met predefined data quality thresholds for resting EEG and VEP, respectively. Implementing mobile EEG/VEP was feasible and acceptable in rural Ethiopia, with a relatively high proportion of recordings meeting quality standards.
Title: Implementation of mobile EEG for resting-state and visual evoked potentials in young children in rural Ethiopia
Description:
Children living in low- and middle-income countries (LMIC) are at disproportionately higher risk of neurodevelopmental delays due to exposure to adverse biological and environmental hazards.
In infancy, global developmental assessments, such as the Bayley Scales, are insensitive, do not strongly correlate with later cognitive outcomes, and require adaptation for different populations and cultural contexts.
Electroencephalography (EEG) objectively measures electrical brain activity and may provide early neural markers predictive of long-term cognitive outcomes.
The visual evoked potential (VEP) interrogates the efficiency of visual cortical processing and reflects neural processing speed.
Mobile EEG enables the assessment of neural processing in settings where such technologies were historically inaccessible.
This paper describes the experiences and lessons learned from implementing mobile EEG and VEP in rural Amhara, Ethiopia as part of the Longitudinal Infant Growth and Development (LIDG) study (NCT06296238).
We describe adaptations and strategies to address and optimize data capture (e.
g.
, dry electrode tips to improve scalp contact, tailored protocols, and adequate equipment specifications), environmental challenges (e.
g.
, space constraints, lack of water supply, power outage) and cultural factors (e.
g.
, hair type) unique to the study setting and population.
Our formative research underscored the importance of creating awareness among community members (e.
g.
, mothers, fathers, and religious leaders) and local clinicians to improve community engagement and buy-in.
Culturally sensitive child behavior management techniques were also critical to ensure EEG completion and high data quality.
With community sensitization, we had high consent rates for EEG/VEP (>90%).
We completed EEG recordings within an average ± standard deviation of 20 ± 11 minutes.
After data processing, approximately 90% and 70% of participants met predefined data quality thresholds for resting EEG and VEP, respectively.
Implementing mobile EEG/VEP was feasible and acceptable in rural Ethiopia, with a relatively high proportion of recordings meeting quality standards.

Related Results

THE EFFECT OF PETHIDINE ON THE NEONATAL EEG
THE EFFECT OF PETHIDINE ON THE NEONATAL EEG
SUMMARYThirty‐two preterm infants were monitored with an on‐line cotside EEG system for periods of up to nine days. Changes in the normal pattern of discontinuity of the EEG were s...
Bithermal caloric test results and vestibular evoked myogenic potentials in patients with vestibular migraine
Bithermal caloric test results and vestibular evoked myogenic potentials in patients with vestibular migraine
Objectives: The aim of this study was to study the ocular vestibular evoked myogenic potentials, cervical vestibular evoked myogenic potentials, and bithermal caloric t...
Evaluation of Mathematical Cognitive Functions with the Use of EEG Brain Imaging
Evaluation of Mathematical Cognitive Functions with the Use of EEG Brain Imaging
During the last decades, the interest displayed in neurocognitive and brain science research is relatively high. In this chapter, the cognitive neuroscience field approach focuses ...
Perceptions of Telemedicine and Rural Healthcare Access in a Developing Country: A Case Study of Bayelsa State, Nigeria
Perceptions of Telemedicine and Rural Healthcare Access in a Developing Country: A Case Study of Bayelsa State, Nigeria
Abstract Introduction Telemedicine is the remote delivery of healthcare services using information and communication technologies and has gained global recognition as a solution to...
Evaluating the mobile MUSE EEG headband for studying resting state EEG and event-related potentials
Evaluating the mobile MUSE EEG headband for studying resting state EEG and event-related potentials
We examined whether and how tactile EEG experiments could be done through self-assessments by participants at home or through online experiments with consumer-grade mobile EEG devi...
Evaluating the mobile MUSE EEG headband for studying resting state EEG and event-related potentials.
Evaluating the mobile MUSE EEG headband for studying resting state EEG and event-related potentials.
We investigated whether a consumer-grade mobile EEG system such as the MUSE device can be used for online EEG experiments. Five students participated in an online experiment where ...

Back to Top