XEN® stent complications: a case series

View through CrossRef
Abstract Background XEN® gel stent (Allergan, Dublin/Republic of Ireland) is a relatively new microinvasive glaucoma device providing an ab-interno approach to the subconjunctival space for aqueous drainage and reduction of intraocular pressure. It is thought to be less invasive, reduce surgical time and post-operative infection rates compared with traditional glaucoma procedures. Little information however, has been published regarding complications and subsequent management. Case presentation The authors highlight five complicated cases of XEN® stent insertion, how they were managed and key learning points. Cases include: entire stent found at the bottom of the anterior chamber several months after uncomplicated insertion, stent broke into multiple pieces during manipulation within subconjunctiva, XEN45 stent migrated into the anterior chamber 7 months post-operatively and a case of limbal-based conjunctival dissection during open revision which lead to additional scarring around the stent and subsequent raised intraocular pressure. Conclusions We present some new and interesting complications of XEN implant as well as potential management options. This can assist clinical decision-making and enable better pre-operative discussions with patients regarding risks of surgery.
Springer Science and Business Media LLC
Title: XEN® stent complications: a case series
Description:
Abstract Background XEN® gel stent (Allergan, Dublin/Republic of Ireland) is a relatively new microinvasive glaucoma device providing an ab-interno approach to the subconjunctival space for aqueous drainage and reduction of intraocular pressure.
It is thought to be less invasive, reduce surgical time and post-operative infection rates compared with traditional glaucoma procedures.
Little information however, has been published regarding complications and subsequent management.
Case presentation The authors highlight five complicated cases of XEN® stent insertion, how they were managed and key learning points.
Cases include: entire stent found at the bottom of the anterior chamber several months after uncomplicated insertion, stent broke into multiple pieces during manipulation within subconjunctiva, XEN45 stent migrated into the anterior chamber 7 months post-operatively and a case of limbal-based conjunctival dissection during open revision which lead to additional scarring around the stent and subsequent raised intraocular pressure.
Conclusions We present some new and interesting complications of XEN implant as well as potential management options.
This can assist clinical decision-making and enable better pre-operative discussions with patients regarding risks of surgery.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Occlusion of Xen Gel Stent With Descemet’s Membrane Relieved by Nd:YAG Laser
Occlusion of Xen Gel Stent With Descemet’s Membrane Relieved by Nd:YAG Laser
Abstract: The Xen gel stent is a minimally invasive glaucoma surgical implant designed to decrease intraocular pressure (IOP) by creating an aqueous outflow path into t...
Novel functionalized and patterned surfaces for cardiovascular applications
Novel functionalized and patterned surfaces for cardiovascular applications
Nowadays, cardiovascular diseases are mainly treated by implantation of a metallic or polymeric mesh, called stent, which maintains the artery widely open. This technique shows ver...
One stent versus two stents for distal LM PCI: insights from the experience of a high volume center
One stent versus two stents for distal LM PCI: insights from the experience of a high volume center
Abstract Introduction Distal left main (LM) PCIremains a challenge. One of the most debated issues is whether to use a single vs...
Fluid and Solid Mechanics in Stented Arteries
Fluid and Solid Mechanics in Stented Arteries
Abstract Vascular stents are being used in increasing numbers to correct arterial flow limiting disorders. Although data exist on the in vivo performance of these de...
Comparative outcome analysis of enterprise and neuroform stent-assisted coiling of cerebral aneurysms: A review of the literature
Comparative outcome analysis of enterprise and neuroform stent-assisted coiling of cerebral aneurysms: A review of the literature
Introduction: One of the popular treatment strategies for complex cerebral aneurysms with wide necks or low dome-to-neck ratios is stent-assisted coiling. The most widely used intr...

Back to Top